Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20065B921 + (ML20065B921)
- ML20065B922 + (ML20065B922)
- ML20065B924 + (ML20065B924)
- 05000244/LER-1983-006-01, /01T-0:on 830120,screen House Suction Bay Water Level Dropped Below Suction of Motor Driven & Diesel Driven Fire Pumps,Rendering Fire Suppression Sys Inoperable.Caused by Frazil Ice in Circulating Water Pump Suction + (ML20065B927)
- B14778, Informs NRC Staff That Facility Did Not Comply W/Intent of Fire Protection on Commitments Made on 851001 & 1104 Re Cable Separation Provisions of NRC BTP + (ML20065B928)
- ML20065B930 + (ML20065B930)
- 05000316/LER-1983-017-03, /03L-0:on 830115,during Performance of RHR Sys Isolation Valve Test in Mode 4,RHR Cooldown Valve IMO-128 Closed Above Tech Spec Pressure.Caused by Inaccurate wide-range Indicator Readings + (ML20065B931)
- ML20065B932 + (ML20065B932)
- ML20065B933 + (ML20065B933)
- ML20065B935 + (ML20065B935)
- ML20065B936 + (ML20065B936)
- ST-HL-AE-4739, Submits Annual Report on Property Insurance in Force at Plant,Per 10CFR50.54(w)(2) + (ML20065B942)
- ML20065B943 + (ML20065B943)
- ML20065B944 + (ML20065B944)
- ML20065B947 + (ML20065B947)
- ML20065B949 + (ML20065B949)
- ML20065B951 + (ML20065B951)
- ML20065B954 + (ML20065B954)
- 05000244/LER-1983-004, Forwards LER 83-004/03L-0 + (ML20065B955)
- ML20065B960 + (ML20065B960)
- 05000244/LER-1983-004-03, /03L-0:on 830114,check Valve 862B Declared Inoperable After Failing to Close Promptly During Test of Containment Spray Sys.Maint Performed on Valve.Valve Retested Satisfactorily.Revised Test Method Developed + (ML20065B961)
- ML20065B972 + (ML20065B972)
- ML20065B974 + (ML20065B974)
- ML20065B985 + (ML20065B985)
- ML20065B995 + (ML20065B995)
- 05000387/LER-1983-005, Forwards LER 83-005/03L-0 + (ML20065C019)
- 05000446/LER-1994-003, :on 940305,plant Operator Noticed Tg Load Swings.Cause Could Not Be Determined.Troubleshooting of EHC Sys Performed & Feedback Coil Replaced + (ML20065C026)
- 05000387/LER-1983-005-03, /03L-0:on 830106,during Startup Testing Program, Unidentified RCS Leakage Exceeded 5 Gpm.Caused by Valve Packing Failure.Valve Repacked + (ML20065C029)
- 05000317/LER-1983-007, Forwards LER 83-007/03L-0 + (ML20065C033)
- ML20065C041 + (ML20065C041)
- 05000317/LER-1983-007-03, /03L-0:on 830107,ECCS Pump Room Fan 11 Discharge Damper Discovered Only Partially Open.Cause Unknown.Damper & Similar ECCS Pump Room Ventilation Dampers Locked Open + (ML20065C043)
- 05000237/LER-1983-011, Forwards LER 83-011/01T-0 + (ML20065C045)
- RBG-14-135, Responds to NRC Re Violations Noted in IE Insp Rept 50-458/82-15.Corrective Actions:Weld Treatment Sheet W3-03 Revised to Specify Travel Speed of 1.4 Inches Per Minute at Welding Current of 100 Amperes & 14 Volts + (ML20065C057)
- ML20065C058 + (ML20065C058)
- 05000244/LER-1983-001, Forwards LER 83-001/03L-0 + (ML20065C060)
- ML20065C063 + (ML20065C063)
- 05000318/LER-1983-001, Forwards LER 83-001/03L-0 + (ML20065C066)
- ML20065C073 + (ML20065C073)
- ML20065C076 + (ML20065C076)
- ML20065C081 + (ML20065C081)
- ML20065C087 + (ML20065C087)
- 05000244/LER-1983-001-03, /03L-0:on 830104,valve 9626A Found Mispositioned in Closed Position.Possible Causes Include Human Error & Deliberate Tampering.No Positive Conclusion Reached Even After Exhaustive Investigation + (ML20065C091)
- ML20065C095 + (ML20065C095)
- ML20065C098 + (ML20065C098)
- ML20065C104 + (ML20065C104)
- ML20065C106 + (ML20065C106)
- ML20065C108 + (ML20065C108)
- ML20065C116 + (ML20065C116)
- ML20065C118 + (ML20065C118)
- ML20065C119 + (ML20065C119)
- ML20065C122 + (ML20065C122)