- ML20064L469 + (ML20064L469)
- 05000247/LER-1982-050-03, /03L-0:on 821231,during Startup Following Cycle 5/ 6 Refueling Outage,Amount of Water in Condensate Storage Tank Reduced Below Tech Specs.Caused by Efforts to Minimize Chloride Concentration Into Steam Generators + (ML20064L470)
- ML20064L472 + (ML20064L472)
- 05000361/LER-1983-006-03, /03L-0:on 830107,train B Analyzer 2/3 AIT-9782D2 Failed to Meet Channel Functional Test Per Tech Spec Surveillance Requirement 4.3.2.1 & Declared Inoperable. Caused by Faulty Sample Cell.Cell Replaced + (ML20064L475)
- 05000361/LER-1982-171-03, /03L-0:on 821231,operator Insp Revealed Loss of Position Indication for Control Element Assembly 79 as Indicated by Control Element Assembly Calculator 1.Caused by Faulty Reed Switch.Reed Switch Replaced + (ML20064L481)
- ML20064L482 + (ML20064L482)
- AECM-83-007, Responds to NRC Re Violations Noted in IE Insp Rept 50-416/82-69.Corrective Actions:Fire Rated Hatch Cover Installed & Sealed,Open Fire Doors Closed & Signs Will Be Posted for Fire Door Placement + (ML20064L487)
- 05000321/LER-1981-110, Forwards Updated LER 81-110/03X-1 + (ML20064L488)
- BSEP-94-0105, Forwards Repts Made to Nc Div of Environ Mgt During 1993 Re Noncompliances W/Npdes Permit NC0007064 for Facility.In Future Copies of All Changes &/Or Violations to Permit Will Be Transmitted to NRC + (ML20064L489)
- ML20064L492 + (ML20064L492)
- ML20064L498 + (ML20064L498)
- ML20064L506 + (ML20064L506)
- ML20064L509 + (ML20064L509)
- ML20064L511 + (ML20064L511)
- ML20064L512 + (ML20064L512)
- ML20064L514 + (ML20064L514)
- ML20064L528 + (ML20064L528)
- 05000321/LER-1981-110-03, W/Unit in Hot Standby, Mainstack Monitor Found Inoperative.Caused by Corrosion of Carbon Vanes on Pump B.Vanes Cleaned & Reinstalled in Pump + (ML20064L533)
- ML20064L541 + (ML20064L541)
- ML20064L547 + (ML20064L547)
- ML20064L560 + (ML20064L560)
- ML20064L578 + (ML20064L578)
- ML20064L592 + (ML20064L592)
- ML20064L598 + (ML20064L598)
- ML20064L602 + (ML20064L602)
- ML20064L604 + (ML20064L604)
- ML20064L605 + (ML20064L605)
- ML20064L619 + (ML20064L619)
- ML20064L624 + (ML20064L624)
- ML20064L628 + (ML20064L628)
- 05000361/LER-1983-004-01, /01T-0:on 830116,component Cooling Water Train B Declared Inoperable.Caused by Bent Pickup Contact in Limit Switch LS-5 Preventing Valve from Opening.Switch Contact Repaired,Valve Exercised & Tested Satisfactorily + (ML20064L635)
- ML20064L636 + (ML20064L636)
- ML20064L641 + (ML20064L641)
- RBG-40366, LAR 93-12 to License NPF-47,revising TS to Remove Turbine Overspeed Protection Sys Requirements + (ML20064L643)
- ML20064L644 + (ML20064L644)
- ML20064L648 + (ML20064L648)
- ML20064L651 + (ML20064L651)
- ML20064L658 + (ML20064L658)
- ML20064L659 + (ML20064L659)
- ML20064L670 + (ML20064L670)
- ML20064L673 + (ML20064L673)
- ML20064L687 + (ML20064L687)
- 05000352/LER-1994-004-01, :on 940212,PCIV Inadvertently Isolated Constituting ESF Actuation.Caused by Personnel Error. I&C Technicians & Supervisors Counselled + (ML20064L701)
- AECM-83-013, Responds to NRC Re Violations Noted in IE Insp Rept 50-416/82-76.Corrective Actions:Equipment Clearances Independently Verified,Plant Quality Insp Deviation/Mod Form Generated & Security post-instructions Revised + (ML20064L714)
- ML20064L717 + (ML20064L717)
- ML20064L726 + (ML20064L726)
- 05000335/LER-1983-002, Forwards LER 83-002/03L-0 + (ML20064L727)
- ML20064L729 + (ML20064L729)
- ML20064L734 + (ML20064L734)
- 05000456/LER-1994-002-05, :on 940218,main Control Room Ventilation Dampers Declared Inoperable Due to Battery Failure.Caused by Programmatic Deficiency.Preventive Maint Provided for Damper Actuations + (ML20064L741)