- 05000325/LER-1978-071, Forwards LER 78-071/03L-0 + (ML20064B718)
- ML20064B719 + (ML20064B719)
- ML20064B721 + (ML20064B721)
- ML20064B722 + (ML20064B722)
- 05000325/LER-1978-071-03, /03L-0 on 780905:during Periodic Test,Radiat Monitor D12-RM-NO10B HI-HI Trip Point Drifted to Higher than Permitted Level.Monitor Recalibrated.Drift Appears to Be Isolated Incident;No Further Action Taken + (ML20064B723)
- ML20064B725 + (ML20064B725)
- LIC-94-0052, Forwards Rev 7 to Site Security Plan & Detailed Summary Listing of Changes Made in Rev,Including Revised Plan Format.Rev Withheld (Ref 10CFR73.21) + (ML20064B726)
- 05000281/LER-1978-011, Forwards LER 78-011/03X-1 + (ML20064B727)
- ML20064B729 + (ML20064B729)
- 05000219/LER-1978-018, Forwards LER 78-018/01T-0 + (ML20064B734)
- ML20064B735 + (ML20064B735)
- 05000259/LER-1981-037, Forwards Updated LER 81-037/01X-2 + (ML20064B736)
- 05000219/LER-1978-018-01, /01T-0 on 780916:3 MSIVs(NS03A,NS04A,NS04B) Had Leakage Rates in Excess of Maximum Allowable Due to Stem Packing,Cracked Stellite Weld & Failure of Main Poppet to Seat Properly.Msiv Failures Being Investigated + (ML20064B739)
- 05000280/LER-1978-004-03, /03X-1 on 780305:loss of Svc Water Flow Through Charging Pump Intermediate Seal Cooler Was Caused by Corrosion of Stem of Discharge Gate Valve;Corrosion Was Galvanic(Brass Touching Bronze);Problem Will Be Studied + (ML20064B745)
- 05000277/LER-1978-037-03, /03L-0 on 780901:while Testing ADS Subsys,Timers on Both Loops Were Found Outside the 115-125 Second Limit of Tech Specs Due to Setpoint Drift of Time Delay Relays. Timers Were Calibrated,Retested & Returned to Svc + (ML20064B750)
- 05000278/LER-1978-016-03, /03L-0 on 780904:during Surveillance Test Unit 3 Dmain Steam Radiat Monitor Failed to Cause a Half Scram Due to Defective Transistor.Transitor Was Replaced & Monitor Returned to Svc in 6 Hours + (ML20064B752)
- 05000277/LER-1978-036-03, /03L-0 on 780901:failure of Auxiliary Oil Pump to Start Due to a Ground in Motor.Motor,Baldor Type 1040D, 7 1/2 H.P.,25OV.D.C. Was Replaced & HPCI Sys Tested Satisfactorily W/In 36 Hours.Ads Timers Not W/In Tech Specs + (ML20064B754)
- ML20064B765 + (ML20064B765)
- ML20064B774 + (ML20064B774)
- AECM-82-569, Responds to NRC Re Violations Noted in IE Insp Rept 50-416/82-66.Corrective Actions:All Radiographs Removed from Plant Staff Vault & Transferred to Bechtel & Administrative Procedure 01-S-05-1 Re Storage Revised + (ML20064B778)
- ML20064B790 + (ML20064B790)
- ML20064B794 + (ML20064B794)
- ML20064B805 + (ML20064B805)
- 05000336/LER-1978-022, Forwards LER 78-022/03l-0 + (ML20064B809)
- ML20064B811 + (ML20064B811)
- 05000280/LER-1978-028, Forwards LER 78-028/03L-0 + (ML20064B815)
- 05000336/LER-1978-022-03, /03L-0 on 780906:Loss of Methyl Iodide Removal Efficiency for a Ebfs Train. Cause Unknown + (ML20064B817)
- 05000280/LER-1978-028-03, /03L-0 on 780916:snubber Not Meeting Inspec Criteria Caused by Low Oil Level Due to Leakage at Mating Surface Between Body & End Plate.Holding Bolts Were Tightened & Snubber Was Refilled + (ML20064B825)
- ML20064B832 + (ML20064B832)
- ML20064B840 + (ML20064B840)
- ML20064B847 + (ML20064B847)
- ML20064B849 + (ML20064B849)
- ML20064B851 + (ML20064B851)
- ML20064B855 + (ML20064B855)
- ML20064B856 + (ML20064B856)
- ML20064B863 + (ML20064B863)
- ML20064B872 + (ML20064B872)
- L-78-298, Requests W/Holding Proprietary Info in Inspec Repts 50-250/78-14 & 50-250/78-14 + (ML20064B879)
- 05000328/LER-1993-005, :on 931018,manual Actuations of RT Breakers Occurred Due to Demand Step Counter Malfunctions.Replaced Demand Step Counter + (ML20064B886)
- ML20064B887 + (ML20064B887)
- ML20064B890 + (ML20064B890)
- ML20064B892 + (ML20064B892)
- 05000335/LER-1982-061, Forwards LER 82-061/03L-0 + (ML20064B901)
- ML20064B902 + (ML20064B902)
- ML20064B904 + (ML20064B904)
- ML20064B912 + (ML20064B912)
- ML20064B914 + (ML20064B914)
- 05000265/LER-1994-003-02, :on 940130,two HPCI Room Coolers Declared Inoperable Due to Buildup of Silt.Discharge Valve Opened Wider to Increase Flow Rate & Surveillance Increased from Monthly to Every Two Weeks + (ML20064B916)
- 05000335/LER-1982-061-03, /03L-0:on 821127,during Routine Power Ascension & Positioning for Rod Programming Requirement for Minimizing Control Element Assembly (CEA) Guide Tube Wear,Cea 43 Dropped to Full Insertion.No Cause Found + (ML20064B920)
- ML20064B921 + (ML20064B921)
- RBG-13-964, Final Deficiency Rept Re Inadequacy of Welds to Sustain Design Loads.Initially Reported on 820930.Drawings Revised to Comply W/Asme Requirements.Deficiency Determined Not Reportable Per 10CFR50.55(e) + (ML20064B927)