Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20063N770 + (ML20063N770)
- 05000219/LER-1982-049, Forwards LER 82-049/03L-0.Detailed Event Analysis Encl + (ML20063N772)
- 05000219/LER-1982-049-03, /03L-0:on 820825,seven Hydraulic Snubbers Failed Functional Testing After Being Replaced by Certified Functional Spares.Two Snubbers Had Improper Matl Seals. Caused by Seal Degradation &/Or Worn Poppet Valves + (ML20063N775)
- ML20063N777 + (ML20063N777)
- ML20063N778 + (ML20063N778)
- ML20063N781 + (ML20063N781)
- ML20063N782 + (ML20063N782)
- ML20063N783 + (ML20063N783)
- ML20063N784 + (ML20063N784)
- ML20063N786 + (ML20063N786)
- ML20063N788 + (ML20063N788)
- ML20063N792 + (ML20063N792)
- 05000311/LER-1982-101, Forwards LER 82-101/01T-0.Detailed Event Analysis Encl + (ML20063N794)
- ML20063N797 + (ML20063N797)
- 05000311/LER-1982-101-01, /01T-0:on 820916,svc Water Leakage Discovered in Cooling Coils of Containment Fan Coil Unit 21.Caused by Excessive Erosion of Cooling Coils by Silt.Coils Repaired. New Design Coils Will Be Installed During Next Refueling + (ML20063N801)
- ML20063N803 + (ML20063N803)
- 05000219/LER-1982-048, Forwards LER 82-048/03L-0.Detailed Event Analysis Encl + (ML20063N805)
- 05000293/LER-1982-036, Forwards LER 82-036/03L-0 + (ML20063N812)
- 05000311/LER-1982-099, Forwards LER 82-099/03L-0.Detailed Event Analysis Encl + (ML20063N814)
- 05000311/LER-1982-099-03, /03L-0:on 820902,control Room Operator Received Indication of Low Svc Water Flow on Containment Fan Coil 23. Caused by Silt Buildup in Cooling Coils.Svc Water Flow Control Isolation Valve Cycled + (ML20063N817)
- 05000311/LER-1982-100, Forwards LER 82-100/01T-0.Detailed Event Analysis Encl + (ML20063N818)
- 05000311/LER-1982-061, Forwards LER 82-061/03X-1.Detailed Event Analysis Encl + (ML20063N823)
- 05000311/LER-1982-061-03, /03X-1:on 820716,steam Generator Level Channel II Indication Erratic.Caused by Leakage Past Packing on Root Valve 21BF28.Valve Repacked & Leakage Stopped + (ML20063N826)
- ML20063N847 + (ML20063N847)
- GO2-82-723, Responds to NRC Re Violations Noted in IE Insp Rept 50-397/82-14.Corrective Actions:Bechtel Procedures Reviewed to Ensure That Ae Approvals Obtained & QC Administrative Instruction 15 Issued + (ML20063N850)
- ML20063N855 + (ML20063N855)
- 05000272/LER-1982-073-03, /03L-0:on 820906,calculation Showed That Quadrant Power Tilt Ratio for Bottom Detector N42 Exceeded Max Allowable Limit.Caused by Failed Milliamp Detector Switch in Current Meter Assembly.Assembly Replaced & Channel Tested + (ML20063N856)
- ML20063N861 + (ML20063N861)
- ML20063N862 + (ML20063N862)
- ML20063N873 + (ML20063N873)
- ML20063N877 + (ML20063N877)
- ML20063N878 + (ML20063N878)
- 05000293/LER-1982-035, Forwards LER 82-035/03L-0 + (ML20063N879)
- ML20063N888 + (ML20063N888)
- ML20063N890 + (ML20063N890)
- ML20063N892 + (ML20063N892)
- ML20063N893 + (ML20063N893)
- ML20063N894 + (ML20063N894)
- ML20063N901 + (ML20063N901)
- ML20063N903 + (ML20063N903)
- ML20063N907 + (ML20063N907)
- 05000293/LER-1982-035-03, /03L-0:on 820830,during HPCI Surveillance Test, Gland Seal Condenser Gasket Failed.Caused by Overpressure of Gasket During Startup.Gasket Matl Changed to Rubber Bonded Asbestos.Unit Tested & Returned to Svc + (ML20063N908)
- 05000311/LER-1982-098, Forwards LER 82-098/03L-0.Detailed Event Analysis Encl + (ML20063N911)
- ML20063N916 + (ML20063N916)
- 05000311/LER-1982-098-03, /03L-0:on 820901,indication of Low Svc Water Flow Received on Containment Fan Coil Unit 21.Caused by Silt build-up in Cooling Coils.Svc Water Flow Control Valve Cycled & Coil Unit Tested Satisfactorily + (ML20063N920)
- 05000247/LER-1982-034, Forwards LER 82-034/03L-0 + (ML20063N922)
- 05000247/LER-1982-034-03, /03L-0:on 820828,during Normal Operation,Charging Pump 22 Developed Leak & Was Declared Inoperable.Caused by Defective Gasket on Cylinder Head 4.Gasket Replaced & Pump Returned to Svc + (ML20063N929)
- 05000272/LER-1982-074, Forwards LER 82-074/04L-0.Detailed Event Analysis Encl + (ML20063N931)
- GO2-82-803, Advises That Deficiency Repts Re Electrical Cable Routing, Termination,Labeling,Power Supplies & QC Documentation Have Been Reopened.Interim Repts Will Be Provided by 821218 + (ML20063N934)
- 05000311/LER-1982-012, Forwards LER 82-012/03X-1.Detailed Event Analysis Encl + (ML20063N935)