- ML20063E934 + (ML20063E934)
- 05000237/LER-1982-035, Forwards LER 82-035/03L-0 + (ML20063E939)
- 05000237/LER-1982-035-03, /03L-0:on 820724,offgas Flow Indicated High During Normal Startup.Caused by Cracked Fillet Weld in 2D1 Feedwater Heater Emergency Spill to Normal Heater Drain Line Connection.Weld Cracked Due to Excessive Line Movement + (ML20063E945)
- ML20063E948 + (ML20063E948)
- ML20063E951 + (ML20063E951)
- ML20063E953 + (ML20063E953)
- 05000313/LER-1982-020, Forwards LER 82-020/03L-0 + (ML20063E960)
- ML20063E973 + (ML20063E973)
- 05000313/LER-1982-020-03, /03L-0:on 820805,while at 100% Full Power,Control Rod 11 of Group 7 Dropped.Caused by Control Rod Drive Mechanism Stator Failure.Stator Replaced + (ML20063E974)
- 05000315/LER-1982-060, Forwards LER 82-060/03L-0 + (ML20063E980)
- ML20063E982 + (ML20063E982)
- 05000315/LER-1982-060-03, /03L-0:on 820723,while Shutdown for Refueling, Emergency Diesel Generator Rendered Inoperable When Motor Operated Valves on Cooling Water Supply Closed & Power Supply Removed.Caused by Supervisor Error + (ML20063E990)
- ML20063E998 + (ML20063E998)
- ML20063F010 + (ML20063F010)
- ML20063F058 + (ML20063F058)
- ML20063F077 + (ML20063F077)
- ML20063F081 + (ML20063F081)
- ML20063F087 + (ML20063F087)
- ML20063F096 + (ML20063F096)
- ML20063F104 + (ML20063F104)
- ML20063F120 + (ML20063F120)
- ML20063F122 + (ML20063F122)
- ML20063F124 + (ML20063F124)
- ML20063F128 + (ML20063F128)
- ML20063F133 + (ML20063F133)
- ML20063F138 + (ML20063F138)
- ML20063F142 + (ML20063F142)
- 05000311/LER-1982-075-01, /01T-0:on 820814,1 Gpm Svc Water Leak Discovered on Containment Fan Coil Unit 22.Cause Not Stated.On 820815, Similar Leak Discovered on Unit 24.Unit 22 Repaired by Blanking Flanges in Svc Water Piping to Coil + (ML20063F147)
- W3P82-2309, Informs That Response to NRC 820327 Questions Re Rapid Depressurization & Decay Heat Removal Capability of Facility Design Will Be Provided by 830815 + (ML20063F150)
- ML20063F151 + (ML20063F151)
- ML20063F155 + (ML20063F155)
- 1CAN088210, Forwards Proposed Tech Spec Changes Per , in Response to NUREG-0737,Item III.3.4, Control Room Habitability + (ML20063F157)
- ML20063F162 + (ML20063F162)
- ML20063F163 + (ML20063F163)
- ML20063F167 + (ML20063F167)
- ML20063F202 + (ML20063F202)
- ML20063F206 + (ML20063F206)
- ML20063F209 + (ML20063F209)
- ML20063F212 + (ML20063F212)
- ML20063F220 + (ML20063F220)
- ML20063F228 + (ML20063F228)
- ML20063F230 + (ML20063F230)
- 05000247/LER-1982-028, Forwards LER 82-028/03L-0 + (ML20063F233)
- ML20063F234 + (ML20063F234)
- ML20063F238 + (ML20063F238)
- 05000373/LER-1982-077, Forwards LER 82-077/03L-0 + (ML20063F241)
- 05000247/LER-1982-028-03, /03L-0:on 820720,operator Observed Low Air Flow Condition to R11/R12 Containment Gas & Particulate Monitors. Caused by Moisture on Electrical Leads.Source of Moisture Corrected & Motor Leads Dried & Reconnected + (ML20063F245)
- PY-CEI-NRR-1739, Forwards Revised Valve Relief Requests VR-26 & VR-35 & Refueling Outage Justifications RO-1 & RO-2,as Discussed During 930902 Meeting W/Nrc in Rockville,Md + (ML20063F247)
- ML20063F253 + (ML20063F253)
- ML20063F256 + (ML20063F256)