- ML20063D784 + (ML20063D784)
- 05000361/LER-1982-045, Forwards LER 82-045/03L-0.Detailed Event Analysis Submitted + (ML20063D785)
- JPN-94-006, Forwards Application for Amend to License DPR-59,revising RETS Lcos,Srs & Bases Section for Main Condenser Sjaes,In Ref to NUREG-1433, STS for GE BWRs (BWR/4), Rev 0,dtd Sept 1992 + (ML20063D789)
- 05000361/LER-1982-045-03, /03L-0:on 820723,while in Mode 4,120-volt Ac Vital Bus 2V01 de-energized from Associated Inverter.Caused by Disconnection of Jumper Placed Across Three Fuses During Replacement.Bus re-energized to Alternate Power Supply + (ML20063D791)
- ML20063D792 + (ML20063D792)
- ML20063D793 + (ML20063D793)
- ML20063D795 + (ML20063D795)
- ML20063D797 + (ML20063D797)
- ML20063D798 + (ML20063D798)
- ML20063D811 + (ML20063D811)
- ML20063D812 + (ML20063D812)
- ML20063D816 + (ML20063D816)
- ML20063D837 + (ML20063D837)
- ML20063D848 + (ML20063D848)
- ML20063D854 + (ML20063D854)
- 05000373/LER-1982-063, Forwards LER 82-063/03L-0 + (ML20063D861)
- 05000373/LER-1982-063-03, /03L-0:on 820720,neutron Flux High Setdown Limit for Average Power Range Monitor D Found Calibr to Value of 25% Rated Thermal Power.Caused by Instrument Drift.All Six Channels Recalibr + (ML20063D865)
- 05000373/LER-1982-068, Forwards LER 82-068/03L-0 + (ML20063D868)
- 05000306/LER-1982-010, Forwards LER 82-010/01T-0 + (ML20063D871)
- ML20063D872 + (ML20063D872)
- 05000373/LER-1982-068-03, /03L-0:on 820722,position Indication Lights for SRV-1B21-F013H Failed,Indicating Valve Did Not Open on Demand.Caused by Improper Interaction Between Magnets & Wired Set of Reed Switches.Indication Repaired + (ML20063D874)
- ML20063D877 + (ML20063D877)
- 05000271/LER-1982-011, Forwards LER 82-011/03L-0 + (ML20063D888)
- 05000361/LER-1982-040, Forwards LER 82-040/03L-0.Detailed Event Analysis Submitted + (ML20063D893)
- 05000271/LER-1982-011-03, /03L-0:on 820531,visual Rod Position Indication Lost Leaving Only Computer Readout Available.Caused by Failure of Cooling Fan in Power Supply Mfg by Trygon Electronics,Inc.Power Supply Replaced + (ML20063D894)
- 05000361/LER-1982-040-03, /03L-0:on 820719,control Room Emergency Chiller E-335 Tripped on High Bearing Temp.Caused by Faulty High Temp Bearing Alarm Module.Module Replaced + (ML20063D898)
- 05000306/LER-1982-010-01, /01T-0:on 820618,during Local Leakage Rate Testing at Refueling,One Containment Purge Supply Valve Leaked in Excess at Tech Specs.Cause Not Stated.Blind Flanges Will Be Installed on Containment Purge Penetrations + (ML20063D900)
- ML20063D904 + (ML20063D904)
- ML20063D912 + (ML20063D912)
- ML20063D914 + (ML20063D914)
- ML20063D916 + (ML20063D916)
- ML20063D921 + (ML20063D921)
- ML20063D930 + (ML20063D930)
- ML20063D935 + (ML20063D935)
- ML20063D939 + (ML20063D939)
- ML20063D940 + (ML20063D940)
- ML20063D955 + (ML20063D955)
- ML20063D960 + (ML20063D960)
- 05000346/LER-1982-034, Forwards LER 82-034/03L-0 + (ML20063D971)
- 05000346/LER-1982-034-03, /03L-0:on 820720,manual Actuation Pushbutton for Containment Spray Train 2 Failed to Work.Caused by Manual Actuating Switch MWO-IC-415-82 Becoming Loose from Pushbutton.Assembly Tightened + (ML20063D982)
- 05000373/LER-1982-064, Forwards LER 82-064/03L-0.Detailed Event Analysis Encl + (ML20063D986)
- 05000373/LER-1982-064-03, /03L-0:on 820721,position Indication Lights for Automatic Depressurization Sys Valve 1B21-F0134 Failed to Operate,Indicating Valve Open When Observed Closed.Caused by Improper Interaction Between Magnets & Reed Switches + (ML20063D993)
- ML20063D997 + (ML20063D997)
- 05000416/LER-1982-026, Forwards LER 82-026/03L-0 + (ML20063E002)
- ML20063E008 + (ML20063E008)
- 05000416/LER-1982-026-03, /03L-0:on 820725,smoke Detector Above Steam Tunnel Area Zone 2-08 Alarmed W/O Fire & Would Not Reset.Caused by Initiated Manual Pull Station.Sys Restored & Hourly Fire Watch Discontinued + (ML20063E010)
- ML20063E012 + (ML20063E012)
- 05000271/LER-1982-013, Forwards LER 82-013/03L-0 + (ML20063E017)
- 05000324/LER-1982-084, Forwards LER 82-084/01T-0 + (ML20063E018)
- 05000324/LER-1982-084-01, /01T-0:on 820810,two Control Bldg Ventilation Isolation Dampers Not Receiving Close Signal Upon Detection of Chlorine.Caused by Faulty Original Design.Design Modified & Will Be Installed Prior to Startup + (ML20063E024)
- GO2-82-689, Interim Deficiency Rept Re Johnson Controls Design Issue. Initially Reported on 820720.Analysis of Large Bore Piping & Small Bore Design Underway.Next Rept Expected by 821123 + (ML20063E030)