- 05000416/LER-1982-022, Forwards LER 82-022/03L-0 + (ML20063D080)
- ML20063D086 + (ML20063D086)
- 0CAN088203, Discusses Massive Tone Alert Radio Distribution Program Developed in Response to 820729 & 30 Discussions & 820730 Confirmatory Action Ltr.Oversize Pamphlet Encl.Aperture Card Available in PDR + (ML20063D087)
- ML20063D088 + (ML20063D088)
- 05000327/LER-1982-065, Forwards LER 82-065/03L-0 + (ML20063D090)
- 05000296/LER-1982-031, Forwards LER 82-031/03L-0 + (ML20063D092)
- ML20063D096 + (ML20063D096)
- ML20063D098 + (ML20063D098)
- ML20063D101 + (ML20063D101)
- 05000324/LER-1982-089, Forwards LER 82-089/03L-0 + (ML20063D110)
- ML20063D115 + (ML20063D115)
- ML20063D116 + (ML20063D116)
- 05000327/LER-1982-065-03, /03L-0:on 820528,ice Condenser Intermediate Deck Door Found Frozen Closed.Caused by Water Dripping from Leaking Air Handling Unit Condensate Drain Line Which Had Frozen.Ice Removed & Failed Flange Gasket on Door Replaced + (ML20063D118)
- 05000416/LER-1982-022-03, /03L-0:on 820721,fuel Handling Area Gaseous Effluent Monitor Inoperable.Caused by Fuse Failure.Fuse Replaced & Monitor re-energized.Samples Taken During Period of Inoperability Found Acceptable + (ML20063D119)
- ML20063D122 + (ML20063D122)
- 05000324/LER-1982-089-03, /03L-0:on 820722,review of Plant Maint Procedure Revealed That post-maint Testing of Primary Containment Isolation Valves Per App J Was Not Established.Caused by Administrative Oversight.Procedure Revised + (ML20063D124)
- 05000325/LER-1982-060, Forwards LER 82-060/03L-0 + (ML20063D126)
- ML20063D128 + (ML20063D128)
- ML20063D130 + (ML20063D130)
- AECM-82-295, Final Deficiency Rept PRD-82/17 Re GE Type Hma Relays W/Excessive Length of Uninsulated Leads to Contacts, Initially Reported 820406.Relays Inspected & Insulating Tubing Installed Per GE Ltr.Also Reported Under Part 21 + (ML20063D131)
- ML20063D132 + (ML20063D132)
- 05000325/LER-1982-060-03, /03L-0:on 820528,while Performing Channel Functional Test of HPCI Sys Suction Low Water Level Instrumentation,Cst Instrument 1-E41-LSL-N002 Did Not Actuate within Specs.Caused by Organic Deposit + (ML20063D137)
- 05000296/LER-1982-031-03, /03L-0:on 820716,two Degraded Voltage Relay Timers on 4-kV Sdb 3EC & 3ED Found Set at 0.26-s.Caused by Timer Setpoints Change in 820329 Tech Spec Revision,But Not Incorporated Into SI 4.9.A.4.c.Timers Recalibr + (ML20063D138)
- 05000334/LER-1980-027, Forwards Updated LER 80-027/03L-1 + (ML20063D140)
- ML20063D141 + (ML20063D141)
- 05000324/LER-1982-093, Forwards LER 82-093/03L-0 + (ML20063D144)
- ML20063D145 + (ML20063D145)
- 05000334/LER-1980-027-03, During Maint of Diesel Generator Lube Oil Cooler,Internals of River Water Check Valve Discovered in Cooler.Caused by Flutter Due to High Flow Conditions Eroding Hinge Pin Guide.Valve Replaced + (ML20063D150)
- 05000259/LER-1982-048, Forwards LER 82-048/03L-0 + (ML20063D151)
- 05000280/LER-1982-030-03, /03L-0:on 820526,during Cold Shutdown,Preparations for Filling Reactor Coolant Loop a Resulted in RCS Boron Dilution.Caused by Temporary Malfunction of Boric Acid Flow Controller.Controller Functioning Properly + (ML20063D161)
- ML20063D162 + (ML20063D162)
- ML20063D167 + (ML20063D167)
- 05000280/LER-1982-064-03, /03L-0:on 820530,w/unit at 100% Power,Charging Pump Svc Water Pump 1-SW-P-10B Failed to Develop Sufficient Discharge Pressure.Caused by Insufficient Npsh.Svc Water to Chillers Throttled + (ML20063D172)
- ML20063D174 + (ML20063D174)
- ML20063D177 + (ML20063D177)
- 05000280/LER-1982-033-03, /03L-0:on 820530,w/unit at 96% Power,Charging Pump Svc Water Pump 2-SW-P-10B Failed to Develop Sufficient Discharge Pressure.Caused by Insufficient Npsh.Svc Water to Chillers Throttled + (ML20063D178)
- ML20063D182 + (ML20063D182)
- ML20063D190 + (ML20063D190)
- 05000259/LER-1982-048-03, /03L-0:on 820718,coil for Relay 16A-K37 Failed, Resulting in Partial Primary Containment Isolation.Caused by Burned Out GE Type CR 120A,Model 5000001G002 Coil.Relay Coil Replaced + (ML20063D192)
- W3P82-1733, Forwards Proprietary & Nonproprietary Versions of Waterford 3,Cycle 1 Cpc/Ceac Phase 1 Software Verification Test Rept & Waterford 3,Cycle 1 Cpc/Ceac Phase II Software Verification Test Rept. Affidavit Encl + (ML20063D193)
- ML20063D197 + (ML20063D197)
- 05000259/LER-1982-049, Forwards LER 82-049/03L-0 + (ML20063D198)
- ML20063D201 + (ML20063D201)
- ML20063D205 + (ML20063D205)
- ML20063D209 + (ML20063D209)
- 05000325/LER-1982-088, Forwards LER 82-088/03L-0 + (ML20063D229)
- 05000259/LER-1982-049-03, /03L-0:on 820721 & 23,SI 4.1.A-11 (MSIV Closure Functional Test) & SI 4.5.E.1.c (HPCI Motor Operated Valve Operability Test) & SI 4.5.E.1.d & E (HPCI Flow Rate) Not Performed.Caused by Defective Procedure + (ML20063D239)
- ML20063D253 + (ML20063D253)
- ML20063D262 + (ML20063D262)
- ML20063D264 + (ML20063D264)
- 05000366/LER-1982-072, Forwards LER 82-072/03L-0 + (ML20063D270)