Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000334/LER-1982-026, Forwards LER 82-026/03L-0 + (ML20062G947)
- ML20062G950 + (ML20062G950)
- NUREG-0530, Notice of Availability of Draft Suppl to Fes (NUREG-0530) + (ML20062G951)
- 05000305/LER-1982-009-03, While in Hot Shutdown Prior to Scheduled Refueling Outage,Both Source Range Nuclear Instruments Determined Inoperable.Caused by Water Accumulation in Instrument Canisters + (ML20062G953)
- 05000334/LER-1982-026-03, /03L-0:on 820725,during Investigation of Spurious Alarms from Subcooling Margin Monitor,Monitor Indicated All Eight Incore Thermocouples Spiking.Cause Unknown.Cable Connectors Cleaned + (ML20062G956)
- ML20062G957 + (ML20062G957)
- ML20062G958 + (ML20062G958)
- ML20062G960 + (ML20062G960)
- 05000254/LER-1982-019-03, /03L-0:on 820713,during Calibr of Reactor Automatic Relief Valves,Controllers for Valves 1-203-3B, 3D & 3E Found to Trip at Pressures in Excess of Tech Spec Limits.Caused by Setpoint Calibr Below Limits + (ML20062G961)
- ML20062G963 + (ML20062G963)
- ML20062G967 + (ML20062G967)
- ML20062G968 + (ML20062G968)
- ML20062G969 + (ML20062G969)
- 05000272/LER-1982-043, Forwards LER 82-043/03L-0.Detailed Event Analysis Encl + (ML20062G970)
- ML20062G971 + (ML20062G971)
- ML20062G975 + (ML20062G975)
- ML20062G976 + (ML20062G976)
- ML20062G978 + (ML20062G978)
- 05000272/LER-1982-043-03, /03L-0:on 820704,control Room Operator Received Air Particulate Detector Trouble Alarm on Panel 1RP1.Caused by Exhausted Filter Paper Supply Roll Due to Increased Use of Paper from Clearing Filter in Fast Mode.Roll Replaced + (ML20062G979)
- ML20062G980 + (ML20062G980)
- ML20062G981 + (ML20062G981)
- ML20062G982 + (ML20062G982)
- 05000339/LER-1990-010-02, :on 901102,reactor Trip from 9% Power Occurred Due to Loss of Normal Feedwater + (ML20062G985)
- ML20062G986 + (ML20062G986)
- ML20062G987 + (ML20062G987)
- ML20062G989 + (ML20062G989)
- ML20062G991 + (ML20062G991)
- 05000334/LER-1982-024, Forwards LER 82-024/03L-0 + (ML20062G992)
- ML20062G993 + (ML20062G993)
- ML20062G995 + (ML20062G995)
- IR 05000312/1990014 + (ML20062G998)
- 05000302/LER-1979-019, Forwards LER 79-019/03L-0 + (ML20062G999)
- 05000334/LER-1982-024-03, /03L-0:on 820718,during Startup,High Temp Alarm Came in on B Component Cooling Pump Bearing.Caused by Failure of Bearing Due to Pump/Motor Misalignment.Pump Vendor Contacted to Investigate Recurring Problem + (ML20062H000)
- ML20062H002 + (ML20062H002)
- ML20062H003 + (ML20062H003)
- ML20062H004 + (ML20062H004)
- ML20062H005 + (ML20062H005)
- ML20062H006 + (ML20062H006)
- ML20062H007 + (ML20062H007)
- ML20062H008 + (ML20062H008)
- ML20062H010 + (ML20062H010)
- ML20062H011 + (ML20062H011)
- ML20062H012 + (ML20062H012)
- ML20062H013 + (ML20062H013)
- 05000237/LER-1982-028, Forwards LER 82-028/03L-0 + (ML20062H014)
- ML20062H015 + (ML20062H015)
- ML20062H017 + (ML20062H017)
- ML20062H019 + (ML20062H019)
- ML20062H020 + (ML20062H020)
- ML20062H021 + (ML20062H021)