Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000361/LER-1982-023, Forwards LER 82-023/03L-0.Detailed Event Analysis Submitted + (ML20055A587)
- 05000361/LER-1982-023-03, /03L-0:on 820608,fire Suppression Water Spray & Sprinkler Sys Initiated by Manual Actuation of Deluge Valve. Cause Not Determined.Alternate Manual Actuators Being Considered + (ML20055A589)
- 05000312/LER-1982-014, Forwards LER 82-014/03L-0.Detailed Event Analysis Submitted + (ML20055A590)
- ML20055A592 + (ML20055A592)
- 05000312/LER-1982-014-03, /03L-0:on 820619,pressurizer Liquid Sample Valve, SFV-70001,opened Properly But Failed to Close Properly on Command.Caused by Ax Relay Not Responding to Close Command. Relay Replaced + (ML20055A593)
- ML20055A594 + (ML20055A594)
- ML20055A595 + (ML20055A595)
- 05000346/LER-1982-028, Forwards LER 82-028/03L-0 + (ML20055A596)
- IR 05000313/1982004 + (ML20055A598)
- 05000346/LER-1982-027, Forwards LER 82-027/03L-0 + (ML20055A601)
- 0CAN048215, Responds to NRC Re Violations Noted in IE Insp Repts 50-313/82-04 & 50-368/82-04.Corrective Actions:Missing Pipe Strap on Line GBD-22 Replaced,Insp of All Seismic Supports Conducted & Manual Valves Mu-23 & 24 Repositioned + (ML20055A603)
- 05000366/LER-1982-059, Forwards LER 82-059/03L-0 + (ML20055A604)
- 05000346/LER-1982-027-03, /03L-0:on 820608,combined Leakage for All Containment Penetration Valves Exceeded Tech Spec Limits. Caused by Component Failure W/Two Valves Failing Due to Misapplication of Seating Matl.Valves Repaired + (ML20055A606)
- 05000249/LER-1982-027, Forwards LER 82-027/01T-0 + (ML20055A607)
- 05000366/LER-1982-059-03, /03L-0:on 820627,RHR Svc Water Pump Failed to Achieve Rated Discharge Pressure & Declared Inoperable. Caused by Leak Through Air Release Valve.Valve Flushed. Flanges Tightened.Sys Returned to Svc + (ML20055A609)
- 05000249/LER-1982-027-01, /01T-0:on 820629,isolation Valve for HPCI Pressure Switch 3-2389D Developed Leak Which Depressurized Sensing Line.Caused by Loose Packing on Isolation Valve to Pressure Switch.Packing Nut Tightened + (ML20055A610)
- 05000361/LER-1982-034, Forwards LER 82-034/01T-0.Detailed Event Analysis Submitted + (ML20055A611)
- AECM-82-324, Forwards Proposed Revisions to FSAR Section 9.5 & App 9A Clarifying Presentation of Fire Protection Program,In Response to Outstanding Items 1(a) & 1(b) Identified in License NPF-13.Info to Be Incorporated Into Next FSAR Amend + (ML20055A613)
- 05000361/LER-1982-034-01, /01T-0:on 820621,discrepancies Discovered Involving Reactor Coolant Pump & Control Element Assembly. Caused by Incorrect Signal Wiring Connections to Core Protection Calculator from Control Element Assembly Inputs + (ML20055A614)
- ML20055A615 + (ML20055A615)
- 05000346/LER-1982-029, Forwards LER 82-029/03L-0 + (ML20055A618)
- ML20055A620 + (ML20055A620)
- 05000346/LER-1982-029-03, /03L-0:on 820608,essential Inverter YV2 Failed, de-energizing 120-volt Ac Essential Bus Y2 & Source Range Detector NI-l.Caused by Component Failure within Regulated Rectifier YRF2.Inverter Y2 Energized + (ML20055A623)
- ML20055A624 + (ML20055A624)
- ML20055A626 + (ML20055A626)
- 05000366/LER-1982-064, Forwards LER 82-064/03L-0 + (ML20055A627)
- ML20055A629 + (ML20055A629)
- 05000361/LER-1982-019, Forwards LER 82-019/03L-0.Detailed Event Analysis Submitted + (ML20055A630)
- ML20055A632 + (ML20055A632)
- ML20055A634 + (ML20055A634)
- 05000361/LER-1982-019-03, /03L-0:on 820604,during Surveillance Testing,Inlet Heater to a Train HEPA Filter/Charcoal Absorber Assembly Cycled on & Off W/No Variation in Air Flow.Caused by Improper Flow Control Switch Selection.Jumpers Installed + (ML20055A635)
- 05000366/LER-1982-064-03, /03L-0:on 820611,standby Gas Treatment Fan B Failed to Start Manually to Purge & Vent Drywell.Caused by Setpoint Drift.Heater Contractor Replaced,Reactor Head Cooling Setpoints Recalibr & Sys Tested + (ML20055A636)
- IR 05000313/1981022 + (ML20055A637)
- ML20055A638 + (ML20055A638)
- ML20055A640 + (ML20055A640)
- RBG-12-986, Interim Deficiency Rept Re Insufficient End Gap of Beam Between Drywell Wall & Primary Shield Wall,Initially Reported 820302.More Detailed Evaluation Necessary.Final Rept Will Be Submitted by 821008 + (ML20055A642)
- 0CAN048221, Forwards NPDES Discharge Monitoring rept,Jan-Mar 1982 + (ML20055A643)
- ML20055A645 + (ML20055A645)
- ML20055A649 + (ML20055A649)
- PNO-III-82-065, on 820711,operator Discovered Smoke Emanating from B Cooling Tower Pump Motor & on 820710,A Cooling Tower Pump Taken Out of Svc Due to Bearing Problems.Repairs Expected to Take at Least 30 Days + (ML20055A651)
- ML20055A653 + (ML20055A653)
- ML20055A655 + (ML20055A655)
- ML20055A656 + (ML20055A656)
- ML20055A658 + (ML20055A658)
- 05000272/LER-1982-040, Forwards LER 82-040/03L-0.Detailed Event Analysis Encl + (ML20055A659)
- IR 05000315/1982005 + (ML20055A661)
- 05000272/LER-1982-040-03, /03L-0:on 820616,filter Failure Alarm Received on containment-plant Vent Radioactivity Monitor.Caused by Exhausted Filter Paper Supply Roll Due to Clearing Filter in Fast Mode.New Roll Installed.Personnel Counseled + (ML20055A662)
- 05000366/LER-1982-051, Forwards LER 82-051/03L-0 + (ML20055A663)
- ML20055A665 + (ML20055A665)
- ML20055A666 + (ML20055A666)
- AECM-82-320, Advises That J Hendrie Replaced E Hammond on Safety Review Committee + (ML20055A667)