- 05000334/LER-1981-006, Forwards Updated LER 81-006/03X-1.Detailed Event Analysis Encl + (ML20054M062)
- ML20054M064 + (ML20054M064)
- 05000280/LER-1982-035-03, /03L-0:on 820607,w/unit at Full power,TV-IA-201A Would Not Remain Closed After High Radiation Test Signal Cleared.Caused by Incomplete Valve Contact Due to Loosened Limit Switch Mounting Plate.Plate Secured + (ML20054M065)
- ML20054M066 + (ML20054M066)
- ML20054M068 + (ML20054M068)
- ML20054M069 + (ML20054M069)
- ML20054M070 + (ML20054M070)
- ML20054M071 + (ML20054M071)
- 05000334/LER-1982-020-03, /03L-0:on 820610,chlorine Detector CLA-VS-101B, Found to Have Slow Trip Rate.Caused by Dirty Wick.Wick Checked & Cleaned.Procedure Revised to Replace Demineralized Water W/Distilled Water + (ML20054M072)
- 05000369/LER-1982-046-03, /03L-0:on 820601,flow Recorder Found Recording Less than Calculated Flow Due to Deviation of Internal Electronic Zero Position.Caused by Severe Electrical Storm. Internal Electronic Zero Position Reset + (ML20054M073)
- 05000334/LER-1981-006-03, During Surveillance Tests on Low Head Safety Injection Pumps,Water in Recirculation Line on Refueling Water Storage Tank Found Frozen.Caused by Heat Trace Circuit Thermostat Line in Off Position + (ML20054M075)
- ML20054M076 + (ML20054M076)
- ML20054M077 + (ML20054M077)
- 05000325/LER-1982-062, Forwards LER 82-062/03L-0 + (ML20054M078)
- ML20054M080 + (ML20054M080)
- ML20054M081 + (ML20054M081)
- ML20054M082 + (ML20054M082)
- ML20054M083 + (ML20054M083)
- W3P82-1658, Responds to Fj Miraglia Re Circulation & Cooldown Procedure OP-901-051.NRC Concerns Will Be Incorporated.Reactor Vessel Head Metal Temp Monitoring Sys Not Needed Per Discussions W/Nsss Vendor + (ML20054M084)
- 05000324/LER-1982-048, Forwards Updated LER 82-048/03L-1 + (ML20054M086)
- ML20054M088 + (ML20054M088)
- ML20054M089 + (ML20054M089)
- ML20054M090 + (ML20054M090)
- ML20054M091 + (ML20054M091)
- ML20054M093 + (ML20054M093)
- 05000339/LER-1982-034, Forwards LER 82-034/03L-0 + (ML20054M095)
- ML20054M097 + (ML20054M097)
- ML20054M099 + (ML20054M099)
- ML20054M100 + (ML20054M100)
- 05000260/LER-1981-069, Forwards Updated LER 81-069/03X-1 + (ML20054M102)
- ML20054M104 + (ML20054M104)
- ML20054M105 + (ML20054M105)
- 05000339/LER-1982-034-03, /03L-0:on 820608,during Mode 5 Operation,Fire Door S54-13 Between Control Room Air Handler Room & Control Room Chiller Room Would Not Latch.Caused by Loose Latching Mechanism.Latch Tightened & Door Verified Operable + (ML20054M107)
- 05000247/LER-1982-022, Forwards LER 82-022/03L-0 + (ML20054M108)
- 05000327/LER-1982-070-01, /01T-0:on 820618,discovered Possible Inoperability of Containment Sump Level Instrument Loops in Event of Loca.Possibly Caused by Increased Temps Rupturing Sensor Bellows.Procedures Revised + (ML20054M110)
- 05000260/LER-1981-069-03, While Performing Special Instruction 4.1.A-8,scram Discharge Level Switch 2-LS-85-45E Inoperable.Caused by Separation of Switch Float from Arm.Robertshaw Model SL-305-EI-X Level Switch Replaced + (ML20054M111)
- ML20054M112 + (ML20054M112)
- 05000348/LER-1982-028-03, /03L-0:on 820605,during Performance of FNP-1-STP-22.16,turbine Driven Auxiliary Feedwater Pump Failed to Start.Caused by Faulty Limit Switch on Valve HV-3226.Limit Switch Replaced + (ML20054M113)
- ML20054M114 + (ML20054M114)
- 05000348/LER-1982-029-03, /03L-0:on 820605,containment Airlock Declared Inoperable When Airlock Outer Door Could Not Be Shut.Caused by Broken Door Shaft.Shaft Repaired + (ML20054M116)
- ML20054M117 + (ML20054M117)
- 05000247/LER-1982-022-03, /03L-0:on 820526,boric Acid Transfer Pump 22 Found Leaking.Caused by Failure of Mechanical Shaft Seal.New Mechanical Seal Assembly Installed + (ML20054M118)
- 05000369/LER-1982-039, Forwards LER 82-039/01T-0.Detailed Event Analysis Encl + (ML20054M120)
- 05000302/LER-1982-040, Forwards LER 82-040/03L-0 + (ML20054M122)
- ML20054M124 + (ML20054M124)
- B10428, Comments on Systematic Assessment of Licensee Performance for Jul 1980-June 1981,discussed During 820209 Meeting.Mgt Action Will Be Taken Re Surveillance Activities to Achieve Improved Performance + (ML20054M125)
- 05000348/LER-1982-024-03, /03L-0:on 820601,containment Atmosphere Activity Monitors R-11 & R-12 Declared Inoperable When Inboard & Outboard Pumps Tripped Due to Erroneous Low Flow Signal. Caused by Setpoint Drift.Setpoints Adjusted + (ML20054M126)
- 05000302/LER-1982-040-03, /03L-0:on 820603,position Indication for Pilot Operated Relief Valve Found Out of Tolerance.Caused by Instrument Drift.Preamplifier Recalibr & Surveillance Test Satisfactorily Performed + (ML20054M127)
- ML20054M128 + (ML20054M128)
- 05000369/LER-1982-039-01, /01T-0:on 820609,bolts Connecting RHR Heat Exchangers to Seismic Support Steel Found Missing.Caused by Misalignment Due to Design Error.Mod Designed to Negate Bolt Need & Tech Spec 3.5.2(c) Temporarily Waived + (ML20054M129)
- ML20054M130 + (ML20054M130)