Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- IR 05000344/1982010 + (ML20054G861)
- ML20054G865 + (ML20054G865)
- ML20054G867 + (ML20054G867)
- 05000271/LER-1982-009, Forwards LER 82-009/03L-0 + (ML20054G868)
- ML20054G870 + (ML20054G870)
- IR 05000528/1982013 + (ML20054G871)
- IR 05000321/1982011 + (ML20054G872)
- 05000271/LER-1982-009-03, /03L-0:on 820513,during Normal Operation,Reactor Pressure Indicator PI 2-3-55D Indicated Lower than Redundant Indicators.Caused by Degraded 24-volt Dc Power Supply.Power Supply Replaced + (ML20054G873)
- ML20054G874 + (ML20054G874)
- IR 05000219/1982002 + (ML20054G877)
- ML20054G879 + (ML20054G879)
- ML20054G881 + (ML20054G881)
- ML20054G883 + (ML20054G883)
- ML20054G884 + (ML20054G884)
- ML20054G885 + (ML20054G885)
- ML20054G886 + (ML20054G886)
- IR 05000029/1982007 + (ML20054G887)
- 05000029/LER-1982-010, Forwards LER 82-010/03L-0 + (ML20054G888)
- ML20054G890 + (ML20054G890)
- 05000272/LER-1982-037, Forwards LER 82-037/03L-0.Detailed Event Analysis Encl + (ML20054G891)
- 05000325/LER-1982-052, Forwards LER 82-052/03L-0 + (ML20054G895)
- ML20054G897 + (ML20054G897)
- ML20054G898 + (ML20054G898)
- ML20054G899 + (ML20054G899)
- ML20054G902 + (ML20054G902)
- 05000272/LER-1982-037-03, /03L-0:on 820526,svc Water Flow to Containment Fan Coil Unit 12 Found Below Tech Spec Requirements.Caused by Flow Control Valve 12SW223 Stuck in Closed Position.Valve Repaired + (ML20054G904)
- ML20054G906 + (ML20054G906)
- 05000029/LER-1982-010-03, /03L-0:on 820514,during Normal Operation in Mode 1,zone 2 Flow Alarm Sounded.Continuous Flow Revealed Through Alarm Check Auxiliary Valve.Caused by Insufficient Seating.Disc Seal Piece Turned Over + (ML20054G907)
- 05000325/LER-1982-052-03, /03L-0:on 820524,surveillance Revealed That Primary Containment Atmosphere Oxygen analyzer,1-CAC-AT-125 9-2 Would Not Indicate Expected Drywell Oxygen Concentrations.Caused by Calibr Shift on Zero End + (ML20054G908)
- 05000271/LER-1982-010, Forwards LER 82-010/03L-0 + (ML20054G909)
- AECM-82-236, Responds to NRC Re Violations Noted in IE Insp Rept 50-416/82-28.Corrective Actions:Startup Personnel Involved in Testing or Package Assembly Review Instructed to Scrutinize Administrative Functions of Test Documentation + (ML20054G911)
- IR 05000277/1982007 + (ML20054G913)
- 05000271/LER-1982-010-03, /03L-0:on 820513 & 27,RHR Svc Water Breaker Tripped Free When Pump Started.Caused by Worn Prop.Ge Model 416 250-8HB Breaker Prop Replaced.Breaker Tested Satisfactorily & Returned to Svc + (ML20054G917)
- ML20054G918 + (ML20054G918)
- ML20054G919 + (ML20054G919)
- ML20054G921 + (ML20054G921)
- ML20054G922 + (ML20054G922)
- ML20054G923 + (ML20054G923)
- ML20054G924 + (ML20054G924)
- ML20054G926 + (ML20054G926)
- 05000280/LER-1982-059-03, /03L-0:on 820517,during Recorder Pen Check,Pen on FR-GW-100 (Process Vent) Did Not Correspond to Actual Process Vent Flow Per Tech Spec.Caused by Seized Recorder Motor Bearing Due to Lack of Lubrication.Bearing Replaced + (ML20054G927)
- 05000328/LER-1982-063, Forwards LER 82-063/03L-0 + (ML20054G928)
- ML20054G930 + (ML20054G930)
- ML20054G932 + (ML20054G932)
- IR 05000416/1982028 + (ML20054G936)
- 05000280/LER-1982-062-03, /03L-0:on 820520,PT-27 Revealed Low Ampere Readings for Circuit 7A in Panels 8 & 9,contrary to Tech Spec.Caused by Damaged Tapes.Tapes Replaced + (ML20054G937)
- ML20054G938 + (ML20054G938)
- ML20054G939 + (ML20054G939)
- ML20054G940 + (ML20054G940)
- ML20054G941 + (ML20054G941)
- 05000280/LER-1982-029-03, /03L-0:on 820518,during Periodic Test 2-PT-39B-2 Snubbers 2-RC-HSS-162 & 163 Found to Have Empty Remote Reservoir.Caused by Damaged O Ring on Common Valve Block. O Ring Replaced + (ML20054G942)