Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20043F391 + (ML20043F391)
- 05000395/LER-1990-008, :on 900505,energizing of Sequencer Initiated Undervoltage Sequence Causing ESF Bus a to Deenergize. Caused by Incorrectly Installed Undervoltage Circuit Agastat Relay.Relay Rewired + (ML20043F394)
- ML20043F395 + (ML20043F395)
- ML20043F398 + (ML20043F398)
- ML20043F400 + (ML20043F400)
- ML20043F402 + (ML20043F402)
- ML20043F405 + (ML20043F405)
- ML20043F408 + (ML20043F408)
- ML20043F409 + (ML20043F409)
- ML20043F410 + (ML20043F410)
- ML20043F411 + (ML20043F411)
- HL-1137, Monthly Operating Repts for May 1990 for Plant Hatch,Units 1 & 2 + (ML20043F412)
- ML20043F415 + (ML20043F415)
- ML20043F420 + (ML20043F420)
- ML20043F426 + (ML20043F426)
- ML20043F427 + (ML20043F427)
- ML20043F428 + (ML20043F428)
- ML20043F430 + (ML20043F430)
- ML20043F431 + (ML20043F431)
- ML20043F432 + (ML20043F432)
- ML20043F433 + (ML20043F433)
- 0CAN069009, Informs of Receipt of Necessary Approvals to Transfer Operating Responsibilities of Plant to Entergy Operations, Per Amends 128 & 102 to Licenses DPR-51 & NPF-6, Respectively.Extension of Amend Request Unnecessary + (ML20043F434)
- ML20043F436 + (ML20043F436)
- ML20043F439 + (ML20043F439)
- ML20043F440 + (ML20043F440)
- L-20-009, License Amendment Request - Proposed Change to Technical Specifications Sections 1.1. Definitions, and 5.0 Administrative Controls. for Permanently Defueled Condition + (ML20043F441)
- ML20043F442 + (ML20043F442)
- ML20043F446 + (ML20043F446)
- ML20043F451 + (ML20043F451)
- 05000354/LER-1990-007-02, :on 900517,control Room Received Indication of Half Scram & Isolation of Inboard Reactor Water Cleanup Isolation Valve.Caused by Spurious Trip of Channel a Reactor Protection Sys Epa.Design Change Implemented + (ML20043F452)
- ML20043F453 + (ML20043F453)
- ML20043F455 + (ML20043F455)
- ML20043F457 + (ML20043F457)
- ML20043F458 + (ML20043F458)
- IR 05000206/1990020 + (ML20043F460)
- ML20043F462 + (ML20043F462)
- ML20043F464 + (ML20043F464)
- IR 05000483/1990009 + (ML20043F469)
- PNO-III-90-035, on 900605,35-yr Old Female Patient Received 4.3 Mci Dose of I-131 Instead of Intended Dose of 50 Uci. Caused by Technologist Misunderstanding of Written Prescription.Dual Verification for I-131 Use Initiated + (ML20043F470)
- 05000458/LER-1990-021, :on 900509,RWCU Sys Differential Flow High Trip Instrumentation Inoperable for Period Greater than Allowed by Tech Spec.Caused by Misinterpretation of Tech Spec 3/4.3.2,Table 3.3.2.-1.4.Personnel Retrained + (ML20043F472)
- ML20043F473 + (ML20043F473)
- ML20043F474 + (ML20043F474)
- ML20043F476 + (ML20043F476)
- ML20043F477 + (ML20043F477)
- ML20043F478 + (ML20043F478)
- ML20043F483 + (ML20043F483)
- ML20043F484 + (ML20043F484)
- ML20043F485 + (ML20043F485)
- 05000311/LER-1990-019, :on 900511,ESF Actuation Occurred When Radioactive Noble Gas Monitor 2R12A RMS Channel Spiked High. Caused by Equipment/Design Failures.Several Sys Design Mods Will Eliminate Spurious Actuation + (ML20043F486)
- ML20043F487 + (ML20043F487)
- 05000311/LER-1990-018, :on 900511,containment Purge/Pressure Vacuum Relief Sys Actuated.Caused by Design/Equipment Failures. Lighting Transformer 2HL Replaced + (ML20043F488)