Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20039D859 + (ML20039D859)
- ML20039D861 + (ML20039D861)
- 05000369/LER-1981-187, Forwards LER 81-187/01T-0.Detailed Event Analysis Encl + (ML20039D862)
- ML20039D865 + (ML20039D865)
- 05000369/LER-1981-187-01, /01T-0:on 811210,test Curve Data on Replacement Impeller in Centrifugal Charging Pump 1A Indicated Head at Runout Greater than Required.Caused by Failure to Supply Impeller Assembly Specified on 770119 Purchase Requisition + (ML20039D866)
- ML20039D868 + (ML20039D868)
- ML20039D869 + (ML20039D869)
- 05000369/LER-1981-186, Forwards LER 81-186/03L-0.Detailed Event Analysis Encl + (ML20039D871)
- ML20039D873 + (ML20039D873)
- ML20039D874 + (ML20039D874)
- ML20039D875 + (ML20039D875)
- ML20039D879 + (ML20039D879)
- ML20039D880 + (ML20039D880)
- 05000369/LER-1981-186-03, /03L-0:on 811125,wastewater Treatment Line Radiation Monitor Sample Line Strainer & loss-of-flow Alarm Switch Found Clogged,Inhibiting Radiation Measurement & Alarm.Caused by Orientation of Sample Tap + (ML20039D881)
- ML20039D883 + (ML20039D883)
- 05000369/LER-1981-185, Forwards LER 81-185/03L-0.Detailed Event Analysis Encl + (ML20039D887)
- 05000286/LER-1981-010, Forwards LER 81-010/01T-0 + (ML20039D890)
- 05000369/LER-1981-185-03, /03L-0:on 811118,residual Heat Removal Loops Rendered Inoperable.Caused by Disconnecting Pressurizer Vapor Space Temp Sensor Signal Cable W/Resultant Closing of Inlet Isolation Valve.Work Associated W/Shutdown Request + (ML20039D893)
- 05000286/LER-1981-010-01, /01T-0:on 811208,leak of Approx 1 Pint Per Minute Identified in Fan Cooler Unit 34.Caused by Leak in Tube of Cooling Coils for Motor Cooler.Tube Repaired + (ML20039D894)
- 05000247/LER-1981-030, Forwards LER 81-030/99X-0 + (ML20039D895)
- ML20039D898 + (ML20039D898)
- 05000247/LER-1981-030-99, /99X-0:on 811111,seal Return Flow from RCP Increased to Greater than 5 Gpm.Caused by anti-rotation Pin Failure or Seal Failure.New Seals & Pin of Modified Design Installed + (ML20039D900)
- ML20039D902 + (ML20039D902)
- ML20039D903 + (ML20039D903)
- 05000277/LER-1981-046, Forwards LER 81-046/01T-0.Detailed Event Analysis Submitted + (ML20039D906)
- 05000247/LER-1981-028-03, /03L-0:on 811120,pressurizer Safety Valve PCV-464 Found to Actuate Approx 4% Below Tech Spec Min.Cause Unknown.Valve Readjusted & Retested + (ML20039D908)
- ML20039D909 + (ML20039D909)
- 05000277/LER-1981-046-01, /01T-0:on 811205,trip Setpoints Raised Above Tech Spec Range to Aid Restart of Ventilation Sys.Caused by High Temp Alarms & Isolation Channel Trip After Loss of Reactor Bldg Ventilation.Tech Spec Change Pending + (ML20039D911)
- 05000247/LER-1981-029-03, /03L-0:on 811119,during Test Run of Safety Injection Pump,Motor Emitted Smoke & Did Not Turn.Caused by Frozen Shaft Bushings on Pump Rotating Elements.Pump Replaced + (ML20039D912)
- ML20039D913 + (ML20039D913)
- ML20039D916 + (ML20039D916)
- 05000272/LER-1981-115-03, /03L-0:on 811120,feed Flow Greater That Steam Flow Alarm Received & Steam Generator Level Found Dropping. Caused by Failure of Steam Generator Steam Flow Channel 2 Due to Transmitter Failure + (ML20039D918)
- 05000334/LER-1981-102, Forwards LER 81-102/03L-0 + (ML20039D919)
- ML20039D922 + (ML20039D922)
- ML20039D926 + (ML20039D926)
- ML20039D930 + (ML20039D930)
- ML20039D932 + (ML20039D932)
- ML20039D934 + (ML20039D934)
- 05000219/LER-1981-058, Forwards LER 81-058/03L-0.Detailed Event Analysis Encl + (ML20039D935)
- 05000336/LER-1981-039, Forwards LER 81-039/03L-0 + (ML20039D938)
- 05000219/LER-1981-058-03, /03L-0:on 811111,containment Spray Sys High Drywell Pressure Indicating Switches Found to Trip at Values Greater than Tech Spec Limits.Caused by Instrument Repeatability + (ML20039D940)
- PNO-III-81-120, on 811223,HPCI Sys Inoperative Following Automatic Fire Sprinkler Activation in HPCI Room.Cause of Failure Cannot Be Determined Until Drywell Entry Made. Similar Event Occurred 811129 (PNO-III-81-105) + (ML20039D941)
- ML20039D943 + (ML20039D943)
- 05000369/LER-1981-180, Forwards LER 81-180/03L-0.Detailed Event Analysis Encl + (ML20039D945)
- 05000369/LER-1981-180-03, /03L-0:on 811112,containment Temp Exceeded 120 F Limit & Two Temp Sensors Indicated as High as 140 F.Caused by Mislabeling Containment Ventilation Return Isolation Valve 1RN153.Valve Reopened & Relabeled + (ML20039D947)
- ML20039D948 + (ML20039D948)
- ML20039D949 + (ML20039D949)
- ML20039D951 + (ML20039D951)
- ML20039D952 + (ML20039D952)
- 05000270/LER-1981-018, Forwards LER 81-018/01T-0.Detailed Event Analysis Encl + (ML20039D953)
- 05000336/LER-1981-039-03, /03L-0:on 811203,Channel B of Reactor Protective Sys Became Erratic Due to Failure of Tc Inputs.Caused by Moisture from Steam Leak Accumulating on RTD Leads in Terminal Box That Had Been Left Open + (ML20039D955)