- 05000325/LER-1982-145-03, /03L-0:on 821129,main Steam Safety Relief Valve (SRV) Position Indication Instrument 1-B21-TR-R614,points 2 & 4 Printed Intermittently on Chart Paper.Srv Sonic Detector Lights Inoperable.Caused by Timing Motor Gear Teeth Wea + (ML20028C213)
- IR 05000346/1982032 + (ML20028C214)
- ML20028C215 + (ML20028C215)
- PNO-II-83-001, on 831224,logging Tool Broken Open to Remove Threaded,Scaled 125-mCi Cs-137 Source.Caused by Prof Logging Svcs Employee Action.Complete Decontamination & Proper Disposal of Contaminated Matl to Be Performed + (ML20028C216)
- 05000325/LER-1982-134-03, /03L-0:on 821201,primary Containment Atmosphere Oxygen analyzer,1-CAC-AT-1263-2,indicated Step Increase in Drywell Oxygen Concentration.Caused by 1262-2 Analyzer Experiencing Instrument Zero Shift.Analyzer Recalibr + (ML20028C217)
- ML20028C218 + (ML20028C218)
- ML20028C219 + (ML20028C219)
- ML20028C220 + (ML20028C220)
- 05000325/LER-1982-121, Forwards LER 82-121/03L-0 + (ML20028C222)
- ML20028C223 + (ML20028C223)
- ML20028C224 + (ML20028C224)
- ML20028C225 + (ML20028C225)
- IR 05000344/1982034 + (ML20028C226)
- 05000237/LER-1982-049-03, /03L-0:on 821128,during Quarterly Valve Timing Surveillance DOS 1600-1,torus Inert & Purge Valve 2-1601-56 Would Not auto-close.Caused by Versa Valve Leaking from Weep Hole Due to Hardening of O-ring Seal.Valve Replaced + (ML20028C227)
- 05000295/LER-1982-046, Forwards LER 82-046/03L-0 + (ML20028C228)
- 05000325/LER-1982-121-03, /03L-0:on 821130,RTGB Control switch,1-VA-CS-2581 for Standby Gas Treatment Sys 1B Was in Standby,Not Preferred Position.Caused by Failed Spring Return Function. Switch Repaired,Cleaned & Restored to Svc + (ML20028C230)
- PNO-V-82-051, on 821229,liquid Radwaste Monitor Found Inoperable.Caused by Flow Director Kerotest Valve Being Installed Backwards.Valve Cutout,Reversed & Reinstalled in Proper Direction + (ML20028C231)
- 05000416/LER-1982-154, Forwards LER 82-154/03L-0 + (ML20028C232)
- ML20028C233 + (ML20028C233)
- AECM-82-644, Rsps:On 821229,unidentified Caller Telephoned Threat Re Bomb in Bathroom of Administration Bldg.No Bomb Found.Call Considered Hoax + (ML20028C234)
- 05000295/LER-1982-046-03, /03L-0:on 821203,while Disassembling Discharge Valve,Crosstie Valve Between Boric Acid Transfer Pumps 1A & 1B Found Leaking.Caused by Valve Normal End of Life.Repairs Completed & Pump 1A Returned to Svc + (ML20028C235)
- ML20028C236 + (ML20028C236)
- ML20028C238 + (ML20028C238)
- ML20028C240 + (ML20028C240)
- ML20028C241 + (ML20028C241)
- 05000416/LER-1982-154-03, /03L-0:on 821204,shutdown Cooling Loop a of RHR Secured for Standby Svc Water Loop a Hydrostatic Test.Caused by Need to Perform Hydrostatic Test.Reactor Water Cleanup Used as Alternate DHR Method + (ML20028C242)
- 05000306/LER-1982-025-03, /03L-0:on 821130,one Steam Flow Channel Differed from Redundant Channels During Power Reduction Due to out- of-calibr Transmitter.Cause Not Known.Transmitter Recalibr & Returned to Svc.Transmitter to Be Replaced If Drift Rec + (ML20028C244)
- IR 05000255/1982025 + (ML20028C245)
- 05000324/LER-1982-133, Forwards LER 82-133/03L-0 + (ML20028C246)
- ML20028C247 + (ML20028C247)
- ML20028C248 + (ML20028C248)
- 05000324/LER-1982-133-03, /03L-0:on 821204 & 05,discovered Inoperable RTGB Position Indication for Control Rods 10-31,38-23 & 18-11. Caused by Defective IC Chip & Transistor on Probe Buffer Board of Rod 18-11 & Defective Reed Switch + (ML20028C250)
- ML20028C251 + (ML20028C251)
- ML20028C252 + (ML20028C252)
- ML20028C254 + (ML20028C254)
- 05000325/LER-1982-126, Forwards LER 82-126/03L-0 + (ML20028C255)
- ML20028C256 + (ML20028C256)
- ML20028C257 + (ML20028C257)
- ML20028C258 + (ML20028C258)
- NUREG/CR-2934, Forwards NUREG/CR-2934, Review & Evaluation of Indian Point Probabilistic Safety Study, Final Sandia Rept.W/O Encl + (ML20028C260)
- 05000325/LER-1982-126-03, /03L-0:on 821201,primary Containment Atmosphere Oxygen Analyzer 1-CAC-AT-1259-2 Indicated Unexpected Downward Trend in Drywell Oxygen Concentration.Caused by Instrument Zero Shift.Analyzer Recalibr & Returned to Svc + (ML20028C261)
- ML20028C262 + (ML20028C262)
- ML20028C263 + (ML20028C263)
- ML20028C264 + (ML20028C264)
- PNO-III-83-001, on 821231,during Controlled Shutdown,Two ECCS Degraded Necessitating Declaration of Alert.Shutdown Started Due to Inoperable RHR Pump B.During Shutdown Automatic Depressurization Sys Lost Due to Low Air Pressure + (ML20028C265)
- 05000316/LER-1982-097-03, /03L-0:on 821204,fire Detection Sys Alarm for 4 Kv Switchgear Room Received Due to Pyralarm Detector Alarming for No Apparent Reason.Caused by Low Setpoint.New Detector Installed + (ML20028C266)
- ML20028C267 + (ML20028C267)
- 05000281/LER-1982-075, Forwards LER 82-075/01T-0 + (ML20028C268)
- ML20028C269 + (ML20028C269)
- 05000316/LER-1982-098-03, /03L-0:on 821127,fire Detection Sys Alarm for 4 Kv Switchgear Room Received Due to Pyralarm Detector Alarming. Caused by Low Alarm Setpoint.Pyralarm Replaced + (ML20028C270)
- 05000324/LER-1982-139, Forwards LER 82-139/01T-0 + (ML20028C271)