- ML20011F635 + (ML20011F635)
- NRC-90-0026, Forwards Monthly Operating Rept for Jan 1990 for Fermi Unit 2 & Revised Rept for Dec 1989,correcting Error in Net Electrical Generation Figure + (ML20011F638)
- ML20011F639 + (ML20011F639)
- ML20011F640 + (ML20011F640)
- ML20011F642 + (ML20011F642)
- ML20011F643 + (ML20011F643)
- PNO-III-90-013, on 900227,Agmet Matls (Scrap Matls Firm) Notified Region III That Shipment of Scrap Metal Found Radioactively Contaminated After Arriving in Greenville,Pa. Remaining Matl Isolated Until Health Physicist Retained + (ML20011F644)
- ML20011F647 + (ML20011F647)
- ML20011F648 + (ML20011F648)
- ML20011F649 + (ML20011F649)
- U-601601, Responds to NRC Re Violations Noted in Insp Rept 50-461/89-37.Corrective Actions:Radiation Protection Technicians Provided W/Method for Identifying Radiation Work Permits Which Change Radiological Conditions + (ML20011F650)
- ML20011F651 + (ML20011F651)
- BECO-90-026, Forwards Inservice Insp Plan for 1990 mid-cycle Spring Outage for Facility.Augmented Insp Will Be Performed for Three IGSCC Category a Welds Using Guidance in Generic Ltr 88-01 & Criteria in NRC Bulletin 88-08,Suppl 3 + (ML20011F652)
- ML20011F653 + (ML20011F653)
- ML20011F654 + (ML20011F654)
- ML20011F655 + (ML20011F655)
- BSEP-90-0128, Semiannual Radioactive Effluent Release Rept for Jul-Dec 1989 + (ML20011F656)
- ML20011F657 + (ML20011F657)
- ML20011F658 + (ML20011F658)
- ML20011F660 + (ML20011F660)
- 0CAN039010, Responds to Violations Noted in Insp Repts 50-313/89-39 & 50-368/89-39.Corrective Actions:Procedural Controls for NDE Will Be Upgraded to Incorporate Requirements of ASME Section XI,IWA-2641, Layout of Component Ref Points + (ML20011F661)
- ML20011F664 + (ML20011F664)
- ML20011F665 + (ML20011F665)
- ML20011F667 + (ML20011F667)
- ML20011F668 + (ML20011F668)
- ML20011F673 + (ML20011F673)
- 05000368/LER-1990-002, :on 900131,errors Identified in Calculation Used to Establish Calibr Tables for Steam Generator Water Level Transmitters.Caused by Incorrect Static Pressure Assumption.Trip Setpoint Bistable Increased + (ML20011F674)
- 0CAN039005, Requests Extension to Respond to Violations Noted in Insp Repts 50-313/89-42 & 50-368/89-42 Re ASME Section XI Qualified Welding Procedure Specs + (ML20011F675)
- ML20011F677 + (ML20011F677)
- 05000368/LER-1989-026-01, :on 891112,gaps in Piping Supports on Supply & Return Piping for Containment Coolers Identified.Caused by Inadequate Design Technique Used in Original Support Design. Shims Added Before Restart from Outage + (ML20011F678)
- ML20011F679 + (ML20011F679)
- ML20011F680 + (ML20011F680)
- ML20011F682 + (ML20011F682)
- RBG-32020, Forwards 900222 Emergency Planning Exercise Scenario Containing Exercise Objectives,Observer Info,Narrative Summary,Onsite Messages Including Expected Player Actions & Radiological Info.W/O Encl + (ML20011F688)
- ML20011F695 + (ML20011F695)
- ML20011F697 + (ML20011F697)
- ML20011F698 + (ML20011F698)
- ML20011F700 + (ML20011F700)
- ML20011F701 + (ML20011F701)
- IR 05000445/1990002 + (ML20011F703)
- ML20011F705 + (ML20011F705)
- ML20011F706 + (ML20011F706)
- ML20011F707 + (ML20011F707)
- ML20011F713 + (ML20011F713)
- ML20011F716 + (ML20011F716)
- ML20011F717 + (ML20011F717)
- ML20011F718 + (ML20011F718)
- 05000327/LER-1989-031, :on 891205,RHR Pumps Determined to Have Deadheading Problem Identified by NRC Bulletin 88-004.Caused by Inadequate Technical Response to Bulletin.Training Ltr Issued to 10CFR50.59 Reviewers + (ML20011F719)
- ML20011F720 + (ML20011F720)
- ML20011F722 + (ML20011F722)