List of results
- ML20010D186 + (ML20010D186)
- ML20010D187 + (ML20010D187)
- ML20010D188 + (ML20010D188)
- ML20010D189 + (ML20010D189)
- ML20010D190 + (ML20010D190)
- ML20010D191 + (ML20010D191)
- ML20010D193 + (ML20010D193)
- ML20010D194 + (ML20010D194)
- ML20010D195 + (ML20010D195)
- 05000251/LER-1981-008, Forwards LER 81-008/03L-0 + (ML20010D196)
- ML20010D198 + (ML20010D198)
- ML20010D199 + (ML20010D199)
- ML20010D201 + (ML20010D201)
- 05000327/LER-1981-087, Forwards LER 81-087/03L-0 + (ML20010D202)
- ML20010D203 + (ML20010D203)
- 05000251/LER-1981-008-03, /03L-0:on 810717,while Performing Instrumentation Repairs on Pressurizer Spray Valve PCV-4-455B,RCS Leakage Discovered in Unused & Capped Packing Leakoff Line.Caused by Failure of Stem Seal Bellows & Crack in Nipple + (ML20010D204)
- ML20010D205 + (ML20010D205)
- ML20010D206 + (ML20010D206)
- ML20010D207 + (ML20010D207)
- 05000327/LER-1981-087-03, /03L-0:on 810720,shield Bldg Exhaust Monitor 2-RM-90-100 Declared Inoperable.Caused by Failed Reel Shaft for 10 CFM Moving Filter.Shaft & Bearings Replaced + (ML20010D208)
- ML20010D209 + (ML20010D209)
- ML20010D210 + (ML20010D210)
- ML20010D211 + (ML20010D211)
- ML20010D212 + (ML20010D212)
- ML20010D213 + (ML20010D213)
- 05000364/LER-1981-029-03, /03L-0:on 810720,turbine Driven Auxiliary Feedwater Pump Exhaust Radiation Monitor R60D Declared Inoperable Due to Printed Circuit Failure.Caused by Shorted Diode Between Check Source Mounting Hardware & Pc Card + (ML20010D216)
- 05000364/LER-1981-028-03, /03L-0:on 810717,main Control Board Steam Flow Indicator of FT-474 Instrumentation Loop Failed High.Caused by Transmitter Vent Pipe Break Due to Use of Oversized Valve in Sensing Line.Lighter Valve Installed + (ML20010D218)
- ML20010D219 + (ML20010D219)
- 05000364/LER-1981-030-03, /03L-0:on 810727,steam Generator 2B Steam Flow Transmitter FT-485 Declared Inoperable.Caused by Kerotest Valve Plug Remaining Closed When Valve Handwheel Was Fully Open.Valve Exercised & Valve Plug Opened + (ML20010D220)
- ML20010D222 + (ML20010D222)
- ML20010D223 + (ML20010D223)
- ML20010D224 + (ML20010D224)
- ML20010D225 + (ML20010D225)
- 05000364/LER-1981-031-03, /03L-0:on 810718,pressurizer Level Indicators LI-459,460,461 & 462,pressurizer Heaters,Wide Range RCS Pressure Channel PT402,pressurizer Pressure PT-455 & 456,RCS Pressure PT402 & Subcooling Monitors Input Inoperable + (ML20010D226)
- ML20010D228 + (ML20010D228)
- ML20010D229 + (ML20010D229)
- ML20010D230 + (ML20010D230)
- NUREG-0570, Toxic Vapor Concentrations in the Control Room Following a Postulated Accidental Release Potential Error in Equation 2.2-1 + (ML20010D233)
- ML20010D234 + (ML20010D234)
- 05000287/LER-1981-015, Forwards LER 81-015/01T-0.Detailed Event Analysis Encl + (ML20010D235)
- ML20010D236 + (ML20010D236)
- 05000287/LER-1981-015-01, /01T-0:on 810720,while Attempting to Perform Engineered Safeguard Periodic Test,Low Pressure Injection Pump 3-B Failed to Start.Caused by Personnel Error.Pump Motor Bearings Replaced & Personnel Counseled + (ML20010D237)
- ML20010D238 + (ML20010D238)
- ML20010D239 + (ML20010D239)
- ML20010D240 + (ML20010D240)
- ML20010D241 + (ML20010D241)
- ML20010D242 + (ML20010D242)
- ML20010D243 + (ML20010D243)
- ML20010D244 + (ML20010D244)
- ML20010D245 + (ML20010D245)
- ML20010D247 + (ML20010D247)