- 05000335/LER-1981-032-03, /03L-0:on 810624,plant Personnel Determined Periodic Test of AB Battery Charger Had Not Been Performed. Caused by Interpreting Tech Specs Precisely.Test Satisfactorily Performed + (ML20009G152)
- 05000260/LER-1981-032, Forwards LER 81-032/03L-0 + (ML20009G153)
- ML20009G154 + (ML20009G154)
- IR 05000333/1981014 + (ML20009G155)
- 05000324/LER-1981-059, Forwards LER 81-059/01T-0 + (ML20009G156)
- ML20009G157 + (ML20009G157)
- 05000369/LER-1981-055, Forwards LER 81-055/03L-0.Detailed Event Analysis Encl + (ML20009G158)
- ML20009G159 + (ML20009G159)
- 05000335/LER-1981-029, Forwards LER 81-029/03L-0 + (ML20009G161)
- ML20009G162 + (ML20009G162)
- ML20009G163 + (ML20009G163)
- 05000369/LER-1981-055-03, /03L-0:on 810416,cold Leg Injection Accumulator Declared Inoperable Due to High Level Alarm.Caused by Cold Leg Accumulator Discharge Check Valves Leaking.Valves to Be Repaired & Retested + (ML20009G164)
- 05000260/LER-1981-032-03, /03L-0:on 810702,equipment Air Lock Door 238 Was Not Properly Latched Before Opposite Door Was Opened.Caused by Personnel Error.Personnel Instructed in Correct Operation of Doors + (ML20009G165)
- 05000324/LER-1981-052, Forwards LER 81-052/03L-0 + (ML20009G166)
- ML20009G167 + (ML20009G167)
- 05000364/LER-1981-021, Forwards LER 81-021/03L-0 + (ML20009G168)
- ML20009G169 + (ML20009G169)
- 05000324/LER-1981-059-01, /01T-0:on 810629,valve Lineup for Loop a of RHR in Standby Readiness Was Incorrect.Caused by Control Operator Commencing Plant Startup W/O Knowing That Valve F020A Was Open.Rods Inserted & Sys Lineup Verified + (ML20009G170)
- ML20009G172 + (ML20009G172)
- ML20009G173 + (ML20009G173)
- 05000335/LER-1981-029-03, /03L-0:on 810528,while Performing Engineered Safety Feature Channel Functional Test,Steam Generator Pressure Channel Mc Setpoint Was Less than Tech Specs. Cause of Drift Undetermined.Setpoint Adjusted + (ML20009G175)
- 05000364/LER-1981-021-03, /03L-0:on 810606,overtemp-delta Temp Instrumentation Loop Trip Setpoint Failed to Meet Tolerance Requirements.Caused by Gain Potentiometer Being Out of Adjustment.Potentiometer Adjusted + (ML20009G176)
- 05000324/LER-1981-052-03, /03L-0:on 810609,reactor Recirculation Pump Motor Generator 2A Tripped During Unit Load Changes.Cause Unknown. Dirty Electrical Contacts Found in Field Breaker Closure Circuitry Cleaned + (ML20009G177)
- 05000339/LER-1981-049, Forwards LER 81-049/03L-0 + (ML20009G178)
- ML20009G179 + (ML20009G179)
- ML20009G180 + (ML20009G180)
- ML20009G182 + (ML20009G182)
- 05000369/LER-1981-073-03, /03L-0:on 810428,RHR Isolation Valve 1ND1B Failed to Reopen Following Stroke Test.Cause Not Determined.Limit Switches Adjusted & Functioned Properly When Cycled + (ML20009G183)
- ML20009G184 + (ML20009G184)
- 05000260/LER-1980-058, Forwards Updated LER 80-058/03X-1 + (ML20009G185)
- ML20009G186 + (ML20009G186)
- ML20009G187 + (ML20009G187)
- 05000369/LER-1981-061, Forwards LER 81-061/03L-0.Detailed Event Analysis Encl + (ML20009G190)
- ML20009G191 + (ML20009G191)
- 05000339/LER-1981-049-03, /03L-0:on 810612,during Periodic Test,Casing Cooling Pump 2-RS-P-3A Tripped.Caused by Power Supply Breaker Opening on Overcurrent Due to Excessive Load Created by Misalignment of Bearing Holders & Caps.Bearings Aligned + (ML20009G192)
- ML20009G193 + (ML20009G193)
- ML20009G194 + (ML20009G194)
- ML20009G195 + (ML20009G195)
- 05000369/LER-1981-061-03, /03L-0:on 810420,primary Containment Integrity Lost.Outer Door of Lower Personnel Air Lock Open & Inner Door Closed But Not Sealed.Outer Door Open Due to Faulty Limit Switch & Inner Door Due to Too Quick Closing + (ML20009G196)
- ML20009G197 + (ML20009G197)
- 05000338/LER-1981-041, Forwards LER 81-041/99T-0 + (ML20009G198)
- ML20009G199 + (ML20009G199)
- 05000260/LER-1980-058-03, During Performance of SI 4.1.A-8,scram Discharge Instrument Vol Tank Level Switch 2-LS-85-45F Failed Per IE Bulletin 80-14.Caused by Robertshaw Level Switch Inoperability + (ML20009G200)