- 05000324/LER-1981-061, Forwards LER 81-061/03L-0 + (ML20009F474)
- ML20009F475 + (ML20009F475)
- ML20009F476 + (ML20009F476)
- ML20009F477 + (ML20009F477)
- 05000324/LER-1981-061-03, /03L-0:on 810629,during Test,Diesel Generator Failed to Develop Generator Field Voltage.Caused by Failed Electrical Coil in Field Shorting Device 17 Preventing Generator Field from Flashing When Diesel Started + (ML20009F478)
- ML20009F479 + (ML20009F479)
- 05000339/LER-1981-048-03, /03L-0:on 810613 & 14,intermediate Range Nuclear Instrumentation Channel N-35 Failed.Caused by High Voltage Power Supply Failure & Loss of Detector Voltage Bistable Module.Components Replaced + (ML20009F480)
- ML20009F481 + (ML20009F481)
- ML20009F483 + (ML20009F483)
- 05000321/LER-1981-065, Forwards LER 81-065/03L-0 + (ML20009F485)
- ML20009F486 + (ML20009F486)
- ML20009F487 + (ML20009F487)
- ML20009F488 + (ML20009F488)
- 05000321/LER-1981-065-03, /03L-0:on 810701,instrument N62-N009A Found Inoperable During Offgas Hydrogen Analyzer Test & Calibr. Caused by Component Failure Due to Restricted Immersion Tube in Flame Check Assembly.Component Replaced + (ML20009F489)
- ML20009F490 + (ML20009F490)
- ML20009F491 + (ML20009F491)
- BSEP-81-1369, RO 1-81-57:on 810717,during Review of Wiring Diagram for Reactor Core Isolation Cooling,Two non-electronic Switching Sys Div 2 Cables Found Intermixed W/One Switching Sys Cable in Controlled Logic Panel in Control Room.Review Underway + (ML20009F492)
- ML20009F493 + (ML20009F493)
- ML20009F495 + (ML20009F495)
- ML20009F496 + (ML20009F496)
- 05000369/LER-1981-094, Forwards LER 81-094/03L-0 + (ML20009F497)
- ML20009F498 + (ML20009F498)
- ML20009F499 + (ML20009F499)
- ML20009F500 + (ML20009F500)
- 05000269/LER-1981-013-01, /01T-0:on 810630,backup Function of Isolating & Transfer Diodes in Instrumentation & Control Sys Disabled on All Channels on All Units.Caused by Misinterpretation of Tech Specs.Proposed Tech Spec Change Initiated + (ML20009F501)
- ML20009F502 + (ML20009F502)
- 05000369/LER-1981-094-03, /03L-0:on 810603,flow Rate Measurement Instrumentation on Waste Monitor Tank B Declared Inoperable During Attempted Liquid Waste Release.Caused by Root Valves to Tank Flow Transmitter Left Closed After Equipment Mod + (ML20009F503)
- ML20009F504 + (ML20009F504)
- 05000339/LER-1981-052, Forwards LER 81-052/03L-0 + (ML20009F505)
- ML20009F507 + (ML20009F507)
- ML20009F508 + (ML20009F508)
- 05000269/LER-1981-010, Forwards LER 81-010/03L-0.Detailed Event Analysis Encl + (ML20009F509)
- ML20009F510 + (ML20009F510)
- ML20009F511 + (ML20009F511)
- 05000339/LER-1981-052-03, /03L-0:on 810619,nuclear Instrumentation Channel N-35 Observed to Be Reading Low & Erratic W/Unit Recovering from Turbine Trip.Caused by Failure of High Voltage Power Supply.Power Supply Replaced + (ML20009F512)
- 05000269/LER-1981-010-03, /03L-0:on 810602,turbine Driven Emergency Feedwater Pump Declared Inoperable.Caused by Governor Valve Sticking in Open Position Due to Sys Contamination.Linkage Pin Removed,Governor Valve Freed & Stem Cleaned + (ML20009F513)
- ML20009F514 + (ML20009F514)
- ML20009F515 + (ML20009F515)
- 05000327/LER-1981-070, Forwards LER 81-070/03L-0 + (ML20009F516)
- ML20009F517 + (ML20009F517)
- 05000327/LER-1981-070-03, /03L-0:on 810619,containment Bldg Lower Compartment Air Monitor Valve Failed to Close on Signal. Caused by Loose Screw in Handswitch,Allowing Open Contact to Short Across,Preventing Solenoid Valve from de-energizing + (ML20009F518)