Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20009D450 + (ML20009D450)
- ML20009D451 + (ML20009D451)
- ML20009D452 + (ML20009D452)
- ML20009D453 + (ML20009D453)
- ML20009D454 + (ML20009D454)
- A01746, Comments on NRC to All SEP Licensees Re NRC Plans for Integrated Assessment Phase of Sep.Proposed Priority Ranking Sys Should Include Consideration of Occupational Exposure Required to Install Mods or Perform Maint & Insp + (ML20009D455)
- ML20009D456 + (ML20009D456)
- ML20009D457 + (ML20009D457)
- ML20009D458 + (ML20009D458)
- ML20009D460 + (ML20009D460)
- ML20009D461 + (ML20009D461)
- ML20009D462 + (ML20009D462)
- ML20009D463 + (ML20009D463)
- ML20009D465 + (ML20009D465)
- ML20009D467 + (ML20009D467)
- ML20009D468 + (ML20009D468)
- ML20009D470 + (ML20009D470)
- ML20009D478 + (ML20009D478)
- ML20009D479 + (ML20009D479)
- 05000334/LER-1981-057, Forwards LER 81-057/03L-0 + (ML20009D480)
- ML20009D482 + (ML20009D482)
- ML20009D483 + (ML20009D483)
- 05000334/LER-1981-057-03, /03L-0:on 810610,failed Power Supply for Rate Module of Loop C Main Steam Break Protection During Cooldown Channel 3 Was Discovered.Caused by Bad Transistor on Power Supply & Rate Card.Card Replaced + (ML20009D485)
- ML20009D489 + (ML20009D489)
- ML20009D490 + (ML20009D490)
- 05000266/LER-1981-008, Forwards LER 81-008/01T-0 + (ML20009D493)
- ML20009D494 + (ML20009D494)
- ML20009D495 + (ML20009D495)
- ML20009D496 + (ML20009D496)
- 05000266/LER-1981-008-01, /01T-0:on 810710,four Tubes in Steam Generators Were Verified to Have Degradation Greater than 40% Which Exceeds Plugging Limit of Tech Specs.Caused by Intergranular Attack Due to Caustic.Defective Tubes Plugged + (ML20009D497)
- ML20009D498 + (ML20009D498)
- ML20009D499 + (ML20009D499)
- ML20009D501 + (ML20009D501)
- ML20009D504 + (ML20009D504)
- ML20009D516 + (ML20009D516)
- 05000317/LER-1981-050, Forwards LER 81-050/03L-0 + (ML20009D518)
- ML20009D519 + (ML20009D519)
- ML20009D520 + (ML20009D520)
- ML20009D522 + (ML20009D522)
- 05000317/LER-1981-050-03, /03L-0:on 810613,RCS Gross Leakage Was Found to Be 16 Gpm.Caused by Natural End of Life of Root Valve Packing.Leakoff Line Capped,Reducing Leakage.Valve Will Be Repaired During Next Outage + (ML20009D526)
- ML20009D528 + (ML20009D528)
- ML20009D530 + (ML20009D530)
- 05000315/LER-1981-022, Forwards LER 81-022/03L-0 + (ML20009D535)
- ML20009D536 + (ML20009D536)
- 05000331/LER-1981-024, Forwards LER 81-024/03L-0 + (ML20009D537)
- ML20009D538 + (ML20009D538)
- 05000315/LER-1981-022-03, /03L-0:on 810618,during Surveillance,Feedwater Snubber 1-FWS-1 Found to Have Rotated to Position Allowing Air to Enter Fluid Inlet Ports.During Functional Bench Test, Snubber Failed to Lock Up.Caused by Loose Locknut + (ML20009D540)
- ML20009D543 + (ML20009D543)
- 05000331/LER-1981-024-03, /03L-0:on 810616,drywell Equipment Drain Line Valve CV-3729 Did Not Give Fully Closed Indication During Testing.Caused by Seat Leakage in Solenoid Valve SV-3729. Solenoid Valve Replaced + (ML20009D545)
- IR 05000312/1981018 + (ML20009D546)
- 05000305/LER-1981-022, Forwards LER 81-022/03L-0 + (ML20009D549)