Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20008F668 + (ML20008F668)
- ML20008F669 + (ML20008F669)
- ML20008F670 + (ML20008F670)
- ML20008F673 + (ML20008F673)
- ML20008F675 + (ML20008F675)
- ML20008F678 + (ML20008F678)
- 05000267/LER-1981-020, Forwards LER 81-020/03L-0.Detailed Event Analysis Encl + (ML20008F679)
- ML20008F680 + (ML20008F680)
- 05000348/LER-1981-007, Forwards LER 81-007/01T-0 + (ML20008F681)
- ML20008F682 + (ML20008F682)
- ML20008F683 + (ML20008F683)
- ML20008F685 + (ML20008F685)
- 05000267/LER-1981-020-03, /03L-0:on 810226,primary Coolant Moisture & Oxidants Exceeded Limits.Caused by Circulator Buffer Sys Upset & Helium Circulator Trip Due to 810223 Reactor Scram. Reactor Power Reduced Until Moisture Level Decreased + (ML20008F687)
- 05000348/LER-1981-007-01, /01T-0:on 810402,mathematical Sign Error Was Found in Load Summation in Turbine Driven Auxiliary Feedwater Pump Nozzle Load Design Analysis.Caused by Designer Error. Seismic Restraint Mod Made + (ML20008F688)
- ML20008F689 + (ML20008F689)
- ML20008F691 + (ML20008F691)
- ML20008F693 + (ML20008F693)
- ML20008F694 + (ML20008F694)
- RBG-10-034, Final Deficiency Rept Re Incorrect Input to Finite Element Model Used to Calculate Amplified Floor Response Spectra of Reactor Bldg,Initially Reported on 800912.Concludes Condition Not Reportable Per 10CFR50.55e + (ML20008F695)
- 05000254/LER-1981-007, Forwards LER 81-007/03L-0 + (ML20008F696)
- ML20008F697 + (ML20008F697)
- ML20008F698 + (ML20008F698)
- 05000254/LER-1981-007-03, /03L-0:on 810313,no Position Indication Found on Recirculation Pump 1A Discharge Valve MO-1-202-5A.Caused by Tripped Valve Motor Breaker Due to Several Shorted Conductors in Cable 12507 Leading to Valve Inside Drywell + (ML20008F699)
- A810014, Responds to NUREG-0737 Items II.K.3.16 & 18 Re Reduction of Challenges & Failures of Relief Valves & Mod to Automatic Depressurization Sys Logic,Respectively + (ML20008F700)
- ML20008F701 + (ML20008F701)
- ML20008F704 + (ML20008F704)
- ML20008F705 + (ML20008F705)
- ML20008F706 + (ML20008F706)
- 05000298/LER-1981-003-03, /03L-0:on 810223,RHR-MO-26B Motor Amps Increased & Remained Excessively High When Valve Reached Closed Position.Caused by Limit Switch on Limitorque SMB-O Valve Motor Operator Not Opening & de-energizing Starter + (ML20008F707)
- ML20008F708 + (ML20008F708)
- 05000267/LER-1981-018, Forwards LER 81-018/03L-0.Detailed Event Analysis Encl + (ML20008F710)
- ML20008F711 + (ML20008F711)
- ML20008F712 + (ML20008F712)
- 05000267/LER-1981-018-03, /03L-0:on 810214,sample Flow Alarm Setpoints of Three Dewpoint Moisture Monitors Found Outside Tech Spec. Probably Caused by Previous Misadjustment.Trip Points Readjusted + (ML20008F713)
- ML20008F714 + (ML20008F714)
- ML20008F715 + (ML20008F715)
- 05000298/LER-1981-002, Forwards LER 81-002/03L-0.Detailed Event Analysis Encl + (ML20008F716)
- ML20008F717 + (ML20008F717)
- ML20008F718 + (ML20008F718)
- 05000298/LER-1981-002-03, /03L-0:on 810213,brass Filings Found in Oil Sump of Outboard Motor Bearing of RHR Svc Water Booster Pump. Caused by Loose Inboard Motor Fan & Set Screw.Fan Repaired & Second Set Screw Added + (ML20008F719)
- 05000265/LER-1981-006, Forwards LER 81-006/03L-0 + (ML20008F720)
- ML20008F721 + (ML20008F721)
- 05000265/LER-1981-006-03, /03L-0:on 810312,differential Pressure Between Drywell & Suppression Chamber Was Lost.Caused by Isolation of Differential Pressure Sys Due to Short in Electrical Circuit Resulting in Blown Fuse.Fuse Replaced + (ML20008F722)
- PM-81-292, Forwards Monthly Operating Rept for Mar 1981 + (ML20008F723)
- ML20008F725 + (ML20008F725)
- ML20008F726 + (ML20008F726)
- ML20008F729 + (ML20008F729)
- PM-81-291, Forwards Monthly Operating Rept for Mar 1981 + (ML20008F730)
- ML20008F731 + (ML20008F731)
- ML20008F732 + (ML20008F732)