- TXX-3303, Interim Deficiency Rept Re Unauthorized Field Mods of Hilti-Kwik Concrete Anchor Bolts,Initially Reported on 801001.Anomalies Will Be Identified & Dispositioned Per Procedures for Conforming Items by 811201 + (ML20008F591)
- ML20008F592 + (ML20008F592)
- ML20008F593 + (ML20008F593)
- ML20008F594 + (ML20008F594)
- ML20008F596 + (ML20008F596)
- ML20008F597 + (ML20008F597)
- ML20008F598 + (ML20008F598)
- ML20008F599 + (ML20008F599)
- A01348, Responds to NRC Telcon Requests for Supplemental Info Re Util Evaluation of Revised Westinghouse Low Pressure Turbine Disc Data & Basis for Util Conclusion That Operation Until 1981 Refueling Outage Safe.Reinspection Planned + (ML20008F601)
- ML20008F602 + (ML20008F602)
- ML20008F603 + (ML20008F603)
- ML20008F605 + (ML20008F605)
- ML20008F607 + (ML20008F607)
- ML20008F608 + (ML20008F608)
- ML20008F609 + (ML20008F609)
- ML20008F610 + (ML20008F610)
- ML20008F611 + (ML20008F611)
- ML20008F612 + (ML20008F612)
- ML20008F613 + (ML20008F613)
- ML20008F614 + (ML20008F614)
- ML20008F616 + (ML20008F616)
- ML20008F617 + (ML20008F617)
- ML20008F618 + (ML20008F618)
- ML20008F619 + (ML20008F619)
- ML20008F621 + (ML20008F621)
- AECM-81-140, Forwards Revised Emergency Procedures EP-1 Through EP-9 Which Reflect Agreements Reached at 810226-27 Meeting W/Nrc & During 810309-10 Simulator Demonstrations.Atws Procedure Will Be Submitted by June 1981 + (ML20008F622)
- ML20008F623 + (ML20008F623)
- ML20008F624 + (ML20008F624)
- ML20008F625 + (ML20008F625)
- ML20008F626 + (ML20008F626)
- ML20008F627 + (ML20008F627)
- ML20008F629 + (ML20008F629)
- 05000267/LER-1981-019, Forwards LER 81-019/03L-0.Detailed Event Analysis Encl + (ML20008F630)
- ML20008F631 + (ML20008F631)
- ML20008F633 + (ML20008F633)
- 05000267/LER-1981-019-03, /03L-0:on 810220,plant Operated in Degraded Mode to Repair Pressure Control Valve PV-21243-1.Caused by Excessive Leakage Through 1/2-inch Masoneilan Pressure Control Valve.Valve Stroke Lengthened.Seat & Stem Replaced + (ML20008F634)
- ML20008F636 + (ML20008F636)
- 05000255/LER-1981-012-01, /01T-0:on 810331,safety Injection Tank T-82A Level Decreased Below Requirements.Caused by Leaking Safety Injection Control Valve PCV-3042.Valve Will Be Repaired + (ML20008F637)
- ML20008F639 + (ML20008F639)
- 05000333/LER-1981-025, Forwards LER 81-025/03L-0 + (ML20008F641)
- ML20008F642 + (ML20008F642)
- 05000333/LER-1981-025-03, /03L-0:on 810323,while Conducting Surveillance During Normal Operation,Reactor Water Level Switch Found Set Contrary to Tech Specs.Caused Attributed to Instrument Drift.Switch Adjusted & Weekly Surveillance Performed + (ML20008F643)
- ML20008F646 + (ML20008F646)
- 05000267/LER-1981-017, Forwards LER 81-017/03L-0 + (ML20008F648)
- ML20008F649 + (ML20008F649)
- 05000267/LER-1981-017-03, /03L-0:on 810217,standby Diesel Engine 1B Tripped on High Cooling Water Temp.Caused by Sticking Temp Control Valve.Valve Disassembled,Cleaned & Returned to Svc + (ML20008F650)
- 05000327/LER-1981-036, Forwards LER 81-036/03L-0 + (ML20008F652)
- ML20008F653 + (ML20008F653)
- 05000327/LER-1981-036-03, /03L-0:on 810320,remote Shutdown Monitoring Channel for Steam Generator 4 Pressure Declared Inoperable. Caused by Blown Fuse in Loop Power Supply.Fuse Replaced + (ML20008F655)
- 05000267/LER-1981-021, Forwards LER 81-021/03L-0.Detailed Event Analysis Encl + (ML20008F656)
- ML20008F657 + (ML20008F657)