Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20006E361 + (ML20006E361)
- ML20006E362 + (ML20006E362)
- ML20006E364 + (ML20006E364)
- ML20006E365 + (ML20006E365)
- ML20006E366 + (ML20006E366)
- ML20006E367 + (ML20006E367)
- 05000325/LER-1988-006, :on 880219,numerous Bolt Head Failures of 5/16- Inch X 1/2-inch Silicon Bronze Carriage Bolts Noted in Bus/ Bar Connections of Electrical Switchboards.Caused by Igscc. Bolts Replaced.Reportable Per Part 21 + (ML20006E368)
- ML20006E372 + (ML20006E372)
- 05000338/LER-1990-002, :on 900127,fuel Bldg Ventilation Sys Not Aligned to Discharge Through Auxiliary Bldg HEPA Filter & Charcoal Adsorber Assembly During Fuel Movement.Caused by Personnel Error.Disciplinary Action Taken + (ML20006E377)
- 05000498/LER-1990-001, :on 900103,containment Ventilation Isolation Occurred Due to Loss of Power to Radiation Monitor Actuation Relay.Caused by Technician Lifting Power Lead. Technicians Trained & Counseled + (ML20006E378)
- ML20006E379 + (ML20006E379)
- ML20006E381 + (ML20006E381)
- ML20006E382 + (ML20006E382)
- 05000409/LER-1990-002, :on 900115,discovered That Data Recorded for 18-month Surveillance Test of Diesel Bldg Battery Charger, Completed on 871005,showed Less than 50 Amperes for 4 Consecutive Hours.Memo Issued to Personnel + (ML20006E383)
- ML20006E384 + (ML20006E384)
- 05000344/LER-1990-001, :on 900108,determined That Local Leak Rate Testing Not Performed on Inboard Containment Personnel Air Lock Door Equalizing Valves.On 891226,excessive Leakage Noted at Valve.Maint Procedure Revised + (ML20006E385)
- 05000295/LER-1990-002-01, :on 900116,turbine Driven Auxiliary Feedwater Pump 1A Run Deadheaded,Damaging Pump.Caused by Mgt Error & Procedural Deficiency.Pump Disassembled & Impellar Replaced. Training Conducted + (ML20006E386)
- ML20006E391 + (ML20006E391)
- JPN-90-015, Forwards Response to Generic Ltr 89-13, Svc Water Sys Problems Affecting Safety-Related Equipment. Testing of Circulating Water/Svc Water Sys for Mussels Will Begin Spring 1990 + (ML20006E392)
- 2CAN029006, Requests Relief from ASME Code 1980 Edition,Winter 1981 Addenda,Section XI IWA-4120 & Section III NC-5282.7 Requirements for Radiographic Exam of Welded Repair to Facility Refueling Water Tank + (ML20006E393)
- 05000302/LER-1989-041, :on 891208,partial,simultaneous Withdrawal of Two Control Rod Safety Groups Occurred & Safety Group 3 Control Transferred to Auxiliary Power Supply.Cause Undetermined.Select Relays Replaced + (ML20006E394)
- PM-90-023, Monthly Operating Rept for Jan 1990 for Shoreham Nuclear Power Station Unit 1 + (ML20006E396)
- ML20006E397 + (ML20006E397)
- 05000373/LER-1989-008-01, :on 890228,reactor Vessel Low Water Level 2 Switch Found W/Setpoint in Excess of Reject Limit.Caused by Setpoint Drift.Channel Placed in Tripped Condition & All Static-O-Ring Pressure Switches to Be Replaced + (ML20006E398)
- ML20006E399 + (ML20006E399)
- 05000499/LER-1990-001-01, :on 900108,Train Low Steam Line Pressure Blocking Switch Placed in Blocked Position,Causing Actuation of Safety Injection & ESF Sys.Caused by Lack of Instructions.Training Program Modified + (ML20006E400)
- ML20006E401 + (ML20006E401)
- ML20006E402 + (ML20006E402)
- 05000456/LER-1990-001-04, :on 900112,reactor Tripped During Dc Ground Isolation Activities When Auxiliary Relay Energized,Causing Turbine Governor & Reheat Interceptor Valves to Close.Caused by Increasing Steam Pressure.Valves Closed + (ML20006E404)
- ML20006E405 + (ML20006E405)
- ML20006E407 + (ML20006E407)
- ML20006E409 + (ML20006E409)
- ML20006E412 + (ML20006E412)
- PNO-III-90-008, on 900208,licensee Reported That 42-yr Old Female Patient Undergoing Treatment for Vaginal Cancer Received Dose of Radiation 27% Higher than That Prescribed. NRC Medical Consultant Contracted to Determine Effects + (ML20006E414)
- ML20006E415 + (ML20006E415)
- ML20006E417 + (ML20006E417)
- ML20006E419 + (ML20006E419)
- ML20006E420 + (ML20006E420)
- 05000311/LER-1990-006, :on 900117,control Room General Area Radiation Monitor Spiked High,Resulting in Switching Ventilation Sys to Emergency Mode of Operation.Caused by Damaged Pins on Channel Backplate & Modules.Pins Repaired + (ML20006E424)
- 05000352/LER-1990-001-01, :on 900122,discovered That Monthly Instrument Channel Functional Test for RCIC Steam Supply Pressure Low Missed.Caused by Deficiency in Computer Program Used to Schedule Tests.Computer Program Revised + (ML20006E427)
- PMNS20200012, Steam Generator Task Force Meeting + (ML20006E430)
- ML20006E431 + (ML20006E431)
- ML20006E432 + (ML20006E432)
- ML20006E434 + (ML20006E434)
- ML20006E435 + (ML20006E435)
- ML20006E437 + (ML20006E437)
- ML20006E438 + (ML20006E438)
- ML20006E439 + (ML20006E439)
- 05000311/LER-1990-007, :on 900117,main Steam Line Isolation Signal Actuated During Surveillance for Pressure Transmitter, Causing Isolation Signal & ESF Actuations.Caused by Inadequate Procedure.Panel Labeling Corrected + (ML20006E440)
- 05000370/LER-1989-014-04, :on 891215,discovered That Diesel Generator 2A & 2B Sump Pump Discharge Valve to Turbine Bldg Sump Closed & No Discharge Path Available.Caused by Inappropriate Action. Valves Locked Open & Procedures Revised + (ML20006E443)
- 05000374/LER-1989-009-01, :on 890619,diaphragm Leak Discovered in RCIC Steam Line High Flow Isolation Switch.Caused by 1 & 1/2-inch Tear in Diaphragm.Pressure Differential Switch Replaced & Calibr.Reported Per NRC Bulletin 86-002 + (ML20006E445)