Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- A01645, Responds to IE Bulletin 81-03, Flow Blockage of Cooling Water to Safety Sys Components by Corbicula Sp (Asiatic Clam) & Mytilus Sp (Mussel). No History Exists Indicating Intrusion of Sys by Subj Forms of Life + (ML20004D713)
- 05000265/LER-1981-003-01, /01T-0:on 810202,outboard Steam Isolation Valve MO-2-2301-5 Closed But Would Not Reopen.Caused by Insufficient Torque in Hot Condition to Lift Valve.Valve Limit Switches Adjusted + (ML20004D714)
- ML20004D715 + (ML20004D715)
- ML20004D716 + (ML20004D716)
- 05000267/LER-1981-031-03, /03L-0:on 810427,during Normal Surveillance Testing,Diesel Engine B Tripped & Declutched on Starting. Caused by Load Imbalance Between Engines a & B Due to Normal Wear of Linkage.Linkage Was Adjusted + (ML20004D717)
- ML20004D718 + (ML20004D718)
- 05000296/LER-1981-021, Forwards LER 81-021/03L-0 + (ML20004D719)
- ML20004D720 + (ML20004D720)
- ML20004D721 + (ML20004D721)
- ML20004D722 + (ML20004D722)
- ML20004D723 + (ML20004D723)
- ML20004D724 + (ML20004D724)
- 05000259/LER-1981-022, Forwards LER 81-022/03L-0 + (ML20004D725)
- ML20004D726 + (ML20004D726)
- ML20004D727 + (ML20004D727)
- 05000254/LER-1980-030, Forwards LER 80-030/03L-0 + (ML20004D728)
- ML20004D729 + (ML20004D729)
- 05000296/LER-1981-023, Forwards LER 81-023/03L-0 + (ML20004D730)
- ML20004D731 + (ML20004D731)
- 05000265/LER-1981-009, Forwards LER 81-009/03L-0 + (ML20004D732)
- ML20004D733 + (ML20004D733)
- 05000368/LER-1981-011, Forwards LER 81-011/03L-0 + (ML20004D734)
- ML20004D735 + (ML20004D735)
- 05000317/LER-1981-001, Forwards LER 81-001/01T-0 + (ML20004D736)
- ML20004D737 + (ML20004D737)
- 05000265/LER-1981-009-03, /03L-0:on 810504,while Performing RHR Containment Cooling Valve Operability Test,Breaker for Valve MO-2-1001-37B Tripped During Attempt to Close Valve.Caused by Internal Corrosion Buildup + (ML20004D738)
- 05000317/LER-1981-001-01, /01T-0:on 810114,feedwater Transmitter Out of Calibr,Resulting in Erroneous Adjustments to ex-core Nuclear Instrument Channels.Transmitter Failed to Maintain Calibr. Transmitter Replaced.Cause of Shift in Calibr Not Stated + (ML20004D739)
- 05000296/LER-1981-023-03, /03L-0:on 810510,during Redundant Start Test,Left Bank Starters Would Not Develop Min Rotational Speed.Caused by Sticking Vanes Due to Dirty motor.Ingersoll-Rand Air Start Motors Replaced + (ML20004D740)
- 05000368/LER-1981-011-03, /03L-0:on 810224,review of Plant Protection Sys Surveillance Procedure Identified That Channel A,Steam Generator High Level Trip Setpoint Less Conservative than Required.Caused by Deficiency in Surveillance Procedure + (ML20004D741)
- 05000293/LER-1980-058, Forwards Updated LER 80-058/03L-1 + (ML20004D742)
- ML20004D743 + (ML20004D743)
- 05000296/LER-1981-021-03, /03L-0:on 810507,during Routine startup,3B Recirculation Pump Motor Generator Set Field Breaker Indicated Light Out.Caused by Open Motor Generator Set Field Breaker Trip Coil.Breaker Replaced + (ML20004D744)
- 05000293/LER-1980-058-03, While Conducting HPCI Sys Test,Hpci Sys Declared Inoperable.Possibly Caused by Dirt Which Caused Temporary Malfunction of Turbine Throttle Valve.Tests by Factory Representative Satisfactory + (ML20004D745)
- 05000259/LER-1981-022-03, /03L-0:on 810507,during Refueling,Relay 14A-K19B Found to Exceed Tech Spec Table 3.2.B Requirement for Operation of 6 to 8-s.Caused by Time Delay Relay Out of Calibr.Time Delay Relay Adjusted + (ML20004D746)
- ML20004D747 + (ML20004D747)
- ML20004D748 + (ML20004D748)
- 05000155/LER-1981-009, Forwards LER 81-009/03L-0 + (ML20004D749)
- ML20004D751 + (ML20004D751)
- 05000219/LER-1981-022, Forwards LER 81-022/01T-0 + (ML20004D752)
- ML20004D753 + (ML20004D753)
- 05000155/LER-1981-009-03, /03L-0:on 810507,during Power Operations,Alarm Indicated Abnormal Temp on Reactor Vessel Level Sensing Chambers.Caused by Failed Capacitor in Temp Control Circuitry of Temp Switch Unit.Capacitor Replaced + (ML20004D754)
- 05000219/LER-1981-022-01, /01T-0:on 810520,secondary Containment Integrity Not Maintained Due to Personnel Access Airlock Doors Ajar. Caused by Personnel Error & Loosened Striker Plate on Inside Door.Outside Door Closed & Striker Plate Repaired + (ML20004D755)
- 05000254/LER-1980-030-03, /03L-0:on 801104,1/2-A Diesel Fire Pump Taken Out of Svc to Prevent Damage While Suction Bay Was Dewatered for Maint to Water Pumps.Portable Diesel Pumps Installed to Take Suction from Discharge Flume to Supply Main Fire Loo + (ML20004D756)
- 05000298/LER-1981-007, Forwards LER 81-007/03L-0.Detailed Event Analysis Submitted + (ML20004D757)
- ML20004D758 + (ML20004D758)
- ML20004D760 + (ML20004D760)
- ML20004D761 + (ML20004D761)
- 05000298/LER-1981-007-03, /03L-0:on 810426,diesel Generator 1 Cylinder Temp Increased During Surveillance Procedure 6.5.12.1 W/Reactor in Cold Shutdown.Caused by Temporary Air Pressure Test Gauge Which Fell Off Control Air Supply + (ML20004D762)
- ML20004D763 + (ML20004D763)
- ML20004D764 + (ML20004D764)
- ML20004D765 + (ML20004D765)