- 05000336/LER-1981-012-03, /03L-0:on 810312,both Chlorine Detectors W/ Detector Solution Drip Rates Less than That Allowed Found During Routine Surveillance.Caused by Clogged Detector Solution Filters.Filters Replaced + (ML20003E916)
- 05000327/LER-1981-014, Forwards LER 81-014/03L-0 + (ML20003E917)
- ML20003E918 + (ML20003E918)
- ML20003E919 + (ML20003E919)
- ML20003E920 + (ML20003E920)
- ML20003E921 + (ML20003E921)
- ML20003E922 + (ML20003E922)
- ML20003E923 + (ML20003E923)
- ML20003E925 + (ML20003E925)
- 05000327/LER-1981-014-03, /03L-0:on 810123,testing Procedure SI-158 for Containment Isolation Valves 1-FCV-62-72,73 & 74 Was Determined to Be Inadequate.Caused by Failure to Take Into Account back-pressure in Line.Procedure Changed + (ML20003E926)
- ML20003E927 + (ML20003E927)
- ML20003E928 + (ML20003E928)
- ML20003E929 + (ML20003E929)
- ML20003E930 + (ML20003E930)
- ML20003E932 + (ML20003E932)
- ML20003E934 + (ML20003E934)
- ML20003E935 + (ML20003E935)
- 05000336/LER-1981-013, Forwards LER 81-013/03L-0 + (ML20003E936)
- ML20003E937 + (ML20003E937)
- ML20003E938 + (ML20003E938)
- ML20003E939 + (ML20003E939)
- 05000339/LER-1981-025, Forwards LER 81-025/03L-0 + (ML20003E941)
- ML20003E942 + (ML20003E942)
- ML20003E943 + (ML20003E943)
- ML20003E944 + (ML20003E944)
- 05000336/LER-1981-013-03, /03L-0:on 810312,safety Injection Tank Level Transmitter Indicated Normal Level W/Presence of Low Level Alarm.Caused by Bad Amplifier Card in Transmitter. Transmitter Replaced + (ML20003E946)
- 05000339/LER-1981-025-03, /03L-0:on 810329,bottled Air Pressurization Sys Pressure Fell Below Required Min of 2,300 Psig.Caused by Inadvertent Safety Injection,Causing One Bank of Unit 2 Bottles to Depressurize + (ML20003E949)
- ML20003E954 + (ML20003E954)
- AECM-81-103, Forwards Advanced Copy of Preliminary Response to Meteorological Requirements of NUREG-0654 & Reg Guide 1.23 + (ML20003E955)
- ML20003E956 + (ML20003E956)
- ML20003E957 + (ML20003E957)
- ML20003E959 + (ML20003E959)
- IR 05000382/1981002 + (ML20003E960)
- ML20003E961 + (ML20003E961)
- ML20003E962 + (ML20003E962)
- ML20003E963 + (ML20003E963)
- ML20003E965 + (ML20003E965)
- ML20003E966 + (ML20003E966)
- 05000213/LER-1981-002, Forwards LER 81-002/03L-0 + (ML20003E967)
- ML20003E969 + (ML20003E969)
- ML20003E970 + (ML20003E970)
- 05000213/LER-1981-002-03, /03L-0:on 810322,operator Noticed Mar Readings of HPSI Pump Closed Discharge Pressure Had Not Been Plotted. Caused by New Operators Not Knowledgeable About Test or Requirements & Procedure Not Spelled Out + (ML20003E971)
- ML20003E972 + (ML20003E972)
- ML20003E973 + (ML20003E973)
- ML20003E974 + (ML20003E974)
- ML20003E975 + (ML20003E975)
- ML20003E976 + (ML20003E976)
- ML20003E977 + (ML20003E977)
- ML20003E978 + (ML20003E978)
- ML20003E979 + (ML20003E979)
- ML20003E980 + (ML20003E980)