Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19351F888 + (ML19351F888)
- ML19351F889 + (ML19351F889)
- ML19351F890 + (ML19351F890)
- ML19351F891 + (ML19351F891)
- ML19351F892 + (ML19351F892)
- IR 05000324/1980037 + (ML19351F893)
- ML19351F894 + (ML19351F894)
- ML19351F895 + (ML19351F895)
- ML19351F897 + (ML19351F897)
- ML19351F898 + (ML19351F898)
- 05000260/LER-1981-007, Forwards LER 81-007/03L-0 + (ML19351F899)
- ML19351F900 + (ML19351F900)
- ML19351F901 + (ML19351F901)
- 05000260/LER-1981-007-03, /03L-0:on 810129,during Power Increases,Tech Spec Limit of 13.33 Kw/Ft for Linear Heat Generation Rate Exceeded in One Node.Node Reached 13.77 Kw/Ft.Caused by Xenon Transient Resulting from Increased Core Power + (ML19351F902)
- ML19351F903 + (ML19351F903)
- ML19351F904 + (ML19351F904)
- ML19351F905 + (ML19351F905)
- ML19351F906 + (ML19351F906)
- ML19351F907 + (ML19351F907)
- ML19351F908 + (ML19351F908)
- ML19351F909 + (ML19351F909)
- ML19351F910 + (ML19351F910)
- ML19351F911 + (ML19351F911)
- 05000302/LER-1981-004, Forwards LER 81-004/03L-0 + (ML19351F912)
- ML19351F913 + (ML19351F913)
- 05000302/LER-1981-004-03, /03L-0:on 810119,position Indication for Containment Isolation Valves CAV-2 & CAV-126 Found Inoperable,In Violation of Tech Spec 3.6.3.1.Cause of CAV-2 Inoperability Unknown.Cause of CAV-126 Was Bad Breaker + (ML19351F914)
- 05000369/LER-1981-002, Forwards LER 81-002/01T-0 + (ML19351F915)
- ML19351F916 + (ML19351F916)
- ML19351F917 + (ML19351F917)
- ML19351F918 + (ML19351F918)
- 05000369/LER-1981-002-01, /01T-0:on 810130,during Test,Vent Valve VX-41 & Containment Isolation Valve XV-40 Found Open to Atmosphere, in Violation of Tech Spec 4.9.4.1.Caused by Lack of Valve Checklist & Lack of Periodic Test.Valves Closed + (ML19351F919)
- 05000302/LER-1981-005, Forwards LER 81-005/03L-0 + (ML19351F920)
- ML19351F921 + (ML19351F921)
- ML19351F922 + (ML19351F922)
- ML19351F923 + (ML19351F923)
- 05000302/LER-1981-005-03, /03L-0:on 801215,mechanical Seal for Bldg Spray Pump BSP-1A Found Leaking Greater than 6 Gallons/H,In Violation of Tech Spec 3.6.2.1.Caused by Defective Mechanical Seal.Review of Maint Procedure in Progress + (ML19351F924)
- ML19351F925 + (ML19351F925)
- ML19351F927 + (ML19351F927)
- ML19351F928 + (ML19351F928)
- ML19351F929 + (ML19351F929)
- ML19351F932 + (ML19351F932)
- 05000334/LER-1981-008, Forwards LER 81-008/03L-0 + (ML19351F936)
- ML19351F937 + (ML19351F937)
- ML19351F938 + (ML19351F938)
- 05000334/LER-1981-008-03, /03L-0:on 810112,low Pressure Alarm Received on Safety Injection Accumulator SI-TK-1C.Caused by Leaking Drain Valve.Pressure Restored Above Tech Spec Limit & Valves Will Be Repaired or Replaced During Next Outage + (ML19351F939)
- 05000318/LER-1981-008, Forwards LER 81-008/03L-0 + (ML19351F940)
- ML19351F941 + (ML19351F941)
- 05000318/LER-1981-008-03, /03L-0:on 810113,steam Generator 22 Low Pressure Bistable Meter 2D Found Out of Calibr & Signal Isolator 2-E/E-1023A Failed.Caused by Natural Wear & Aging.Cause of Isolator Failure Not Stated + (ML19351F942)
- ML19351F943 + (ML19351F943)
- ML19351F944 + (ML19351F944)
- 05000317/LER-1981-008, Forwards LER 81-008/01T-0 + (ML19351F945)