Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000338/LER-1980-105, Forwards LER 80-105/03L-0 + (ML19351F538)
- ML19351F539 + (ML19351F539)
- 05000295/LER-1980-054, Forwards LER 80-054/03L-0 + (ML19351F540)
- ML19351F542 + (ML19351F542)
- 05000295/LER-1980-053, Forwards LER 80-053/03L-0 + (ML19351F543)
- 05000339/LER-1980-098, Forwards LER 80-098/03L-0 + (ML19351F545)
- ML19351F546 + (ML19351F546)
- 05000296/LER-1980-058, Forwards LER 80-058/03L-0 + (ML19351F547)
- ML19351F548 + (ML19351F548)
- ML19351F550 + (ML19351F550)
- 05000339/LER-1980-097, Forwards LER 80-097/03L-0 + (ML19351F551)
- ML19351F552 + (ML19351F552)
- 05000339/LER-1980-098-03, /03L-0:on 801208,individual Rod Position Indication for Rod J-9 in Shutdown Bank B Deviated from Demand Position by More than 12 Steps.Caused by Instrument Drift.Rod Position Indicator Channel Recalibr + (ML19351F555)
- 05000368/LER-1980-081, Updated LER 80-081/03L-1:on 801030 & 1212,during Repair Work,Fire Barrier Not Maintained.Caused by Inadequate Instructions.Contractor Instructed to Maintain Firewatch When Penetrations Are Open & to Seal Penetrations Quickly + (ML19351F556)
- 05000339/LER-1980-097-03, /03L-0:on 801209 & 10,containment Penetration Conductor for Polar Crane Energized in Mode for Which Breaker Overload Protection Not Qualified.Caused by Closing Breaker 2B1-2A3 for Insp & Work Completion + (ML19351F557)
- 05000312/LER-1980-047, Forwards LER 80-047/01T-0 + (ML19351F559)
- 05000339/LER-1980-099, Forwards LER 80-099/03L-0 + (ML19351F561)
- ML19351F562 + (ML19351F562)
- 05000296/LER-1980-058-03, /03L-0:on 801207,MSIV 1-14,1-15,1-26,1-27,1-37 & 1-38 & 1-51 Found Leaking.Caused by Seating Surface Deterioration Due to Normal Wear.Valves Repaired + (ML19351F563)
- 05000334/LER-1980-105, Forwards LER 80-105/03L-0 + (ML19351F564)
- ML19351F565 + (ML19351F565)
- 05000334/LER-1980-105-03, /03L-0:on 801205,thermocouple Readings Indicated Temps Below Tech Spec Level Around Boron Injection Tank Outlet Isolation Valves.Caused by Thermocouples Not in Full Contact W/Pipes.Heat Tracing Sys Study Is Being Conducted + (ML19351F566)
- 05000295/LER-1980-053-03, /03L-0:on 800825,component Cooling Liquid Rad Monitor 1RE 0017 Did Not Respond to Check Source & Indicator Was at Bottom of Scale.Caused by Drift in Monitor Plateau. Plateau Reset + (ML19351F567)
- 05000312/LER-1980-047-01, /01T-0:on 801222,IE Bulletin 79-01B Review Found Lack of Qualification Documentation for Flow Transmitter Utilized to Establish Dilution Flow to Prevent Boron Precipitation Following Loca.Cause Not Stated + (ML19351F568)
- 05000155/LER-1980-046, Forwards LER 80-046/03L-0 + (ML19351F569)
- L-81-013, Forwards Monthly Operating Rept for Dec 1980 + (ML19351F571)
- ML19351F572 + (ML19351F572)
- 05000155/LER-1980-046-03, /03L-0:on 801211,during Specfic Gravity checks,21 of 60 Cell Batteries for Reactor Depressurizing Channel a Found Below Required Specific Gravity.Caused by Inadequate Cleaning & Reconnecting of Cell Terminals + (ML19351F573)
- ML19351F574 + (ML19351F574)
- 05000339/LER-1980-099-03, /03L-0:on 801210,overspeed Trip of Steam Driven Auxiliary Feedwater Pump Occurred During post-maint Testing. Probably Caused by Governor Malfunction Due to Air Entrapment.Air Purged from Governor Oil + (ML19351F575)
- 05000339/LER-1980-096, Forwards LER 80-096/03L-0 + (ML19351F576)
- ML19351F577 + (ML19351F577)
- 05000324/LER-1980-113, Forwards LER 80-113/03L-0 + (ML19351F578)
- ML19351F579 + (ML19351F579)
- 05000295/LER-1980-054-03, /03L-0:on 801215,RHR Miniflow Control Valve 1FIC-610A Switch Failed,Making RHR Pump Sys a Unable to Perform.Caused by Faulty Micro Switch.Switch Replaced & Recalibr + (ML19351F580)
- 05000339/LER-1980-096-03, /03L-0:on 801208,power Supply to PQ-2475 in Steam Generator 1A Steam Pressure Channel III Reading Low.Caused by Instrument Drift.Power Supply Recalibr + (ML19351F582)
- 05000324/LER-1980-113-03, /03L-0:on 801211,primary Containment Atmospheric Control Inerting Inlet Isolation Valve 2-CAC-V48 Had Dual Open/Close Position Indication.Cause Unknown.Suppl Rept to Be Issued Following Investigation + (ML19351F583)
- 05000295/LER-1979-097, Forwards LER 79-097/03L-0 + (ML19351F584)
- 05000338/LER-1980-105-03, /03L-0:on 801218,level in 1C Safety Injection Accumulator Dropped Below Tech Spec 3.5.1 Min Level.Caused by Operator Error During Filling Operation.Level Restored + (ML19351F586)
- 05000313/LER-1980-039, Forwards Revised LER 80-039/03L-1 + (ML19351F587)
- ML19351F588 + (ML19351F588)
- 05000313/LER-1980-039-03, During Monthly Surveillance on Lead H Purge Sys,Exhaust Fan VEF-37A Tripped.Caused by Short in Control Sys Which Caused Rectifier to Fail & Fuse to Blow + (ML19351F589)
- ML19351F590 + (ML19351F590)
- 05000324/LER-1980-107, Forwards LER 80-107/03L-0 + (ML19351F592)
- ML19351F593 + (ML19351F593)
- 05000304/LER-1980-032, Forwards LER 80-032/03L-0 + (ML19351F594)
- 05000295/LER-1979-097-03, /03L-0:on 790924,rod Urgent Alarm Received While Attempting to Move Shutdown Bank C.Caused by Failure of Pulser/Oscillator Card in Rod Control Logic Cabinet.New Card Obtained & Installed + (ML19351F596)
- JAFP-81-0010, Forwards Monthly Operating Rept for Dec 1980 + (ML19351F597)
- ML19351F598 + (ML19351F598)
- 05000324/LER-1980-107-03, /03L-0:on 801208,svc Water Sys Primary Coolant Temp Reached 212F.Caused by Removal of Shutdown Cooling Capability for Maint W/Access to Primary Containment Open & Subsequent Heatup of Primary Coolant Due to Decay Heat + (ML19351F599)
- ML19351F600 + (ML19351F600)