Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19345G549 + (ML19345G549)
- 05000324/LER-1981-038, Forwards LER 81-038/03L-0 + (ML19345G550)
- ML19345G551 + (ML19345G551)
- ML19345G552 + (ML19345G552)
- ML19345G553 + (ML19345G553)
- 05000324/LER-1981-038-03, /03L-0:on 810302,primary Containment Atmospheric Monitor Oxygen Analyzer Observed Showing Downscale Indication of Drywell Oxygen Concentration While Other Oxygen Analyzer Indicated Expected Concentration + (ML19345G554)
- ML19345G555 + (ML19345G555)
- ML19345G556 + (ML19345G556)
- 05000324/LER-1981-040, Forwards LER 81-040/03L-0 + (ML19345G557)
- ML19345G558 + (ML19345G558)
- ML19345G559 + (ML19345G559)
- ML19345G560 + (ML19345G560)
- ML19345G561 + (ML19345G561)
- ML19345G562 + (ML19345G562)
- ML19345G563 + (ML19345G563)
- 05000302/LER-1981-017, Forwards LER 81-017/03L-0.Detailed Event Analysis Encl + (ML19345G564)
- ML19345G565 + (ML19345G565)
- 05000324/LER-1981-040-03, /03L-0:on 810303,during Normal Operation,Primary Containment Atmospheric Control Suppression Pool Level Indicator 2-CAC-LI-2601-3 Showed Downscale Level While Level Was Normal.Caused by Blown Fuse in Signal Converter + (ML19345G566)
- 05000316/LER-1981-004, Forwards LER 81-004/03L-0 + (ML19345G567)
- 05000302/LER-1981-017-03, /03L-0:on 810304,during Testing,Discovered That Containment Isolation Valve CFV-16 Would Not Move from mid-position.Caused by Valve Binding on Bushing Due to Insufficient Lubrication + (ML19345G568)
- ML19345G569 + (ML19345G569)
- 05000325/LER-1981-018, Forwards LER 81-018/03L-0 + (ML19345G570)
- ML19345G571 + (ML19345G571)
- ML19345G572 + (ML19345G572)
- ML19345G573 + (ML19345G573)
- 05000325/LER-1981-018-03, /03L-0:on 810302,during Testing,Low Level Switch 1-B21-LIS-N031B-2 Would Not Actuate.Caused by Set Screw Which Secures Instrument Indicator Needle to Actuator Shift Coming Loose & Attaching Itself to Switch Operating Magnet + (ML19345G574)
- 05000324/LER-1981-014, Forwards LER 81-014/03L-0 + (ML19345G575)
- ML19345G576 + (ML19345G576)
- ML19345G577 + (ML19345G577)
- ML19345G578 + (ML19345G578)
- ML19345G579 + (ML19345G579)
- ML19345G580 + (ML19345G580)
- ML19345G581 + (ML19345G581)
- 05000324/LER-1981-014-03, /03L-0:on 810206,during Normal Operation, Suppression Pool to Reactor Bldg Vacuum Breaker Butterfly Valve 2-CAC-V17 Opened Outside Tech Spec Primary Containment Pressure Limits.Caused by Instrument Set Point Drift + (ML19345G582)
- ML19345G583 + (ML19345G583)
- ML19345G584 + (ML19345G584)
- ML19345G585 + (ML19345G585)
- ML19345G586 + (ML19345G586)
- 05000219/LER-1981-010, Forwards LER 81-010/03L-0 + (ML19345G587)
- ML19345G589 + (ML19345G589)
- ML19345G590 + (ML19345G590)
- ML19345G592 + (ML19345G592)
- 05000315/LER-1980-029, Forwards LER 80-029/03L-0 + (ML19345G593)
- ML19345G594 + (ML19345G594)
- ML19345G595 + (ML19345G595)
- ML19345G596 + (ML19345G596)
- ML19345G598 + (ML19345G598)
- ML19345G600 + (ML19345G600)
- ML19345G601 + (ML19345G601)
- ML19345G602 + (ML19345G602)
- ML19345G605 + (ML19345G605)