- 05000271/LER-1980-039, Forwards LER 80-039/03L-0 + (ML19345B484)
- ML19345B485 + (ML19345B485)
- 05000368/LER-1979-022-99, Changes in Control Circuitry of Containment Cooling Fans Discovered Inadvertently Omitted.Caused by Oversight.Mods Completed + (ML19345B486)
- 05000254/LER-1980-028-03, /03L-0:on 801023,diesel Generator Cooling Water Pump Motor 1/2 Found two-thirds Submerged in Water.Caused by Inadequate Vault Sump Pump Sys.Vault Drained & Cooling Water Pump Motor Replaced + (ML19345B487)
- ML19345B490 + (ML19345B490)
- ML19345B491 + (ML19345B491)
- 05000338/LER-1980-095-03, /03L-0:on 801027,fire Doors S71-7,-17 & -19 Found Nonfunctional Due to Inability to Fully Close & Latch on Free Swing from Full Open.Caused by Excessive Use.Doors Temporarily Repaired & New Design Submitted + (ML19345B492)
- 05000255/LER-1980-043-01, /01T-0:on 801106,measured Leakage Through Containment Penetration 14 Exceeded Tech Spec Limit.Cause Under Evaluation.Check Valve & Butterfly Valve Seat Replaced + (ML19345B493)
- 05000321/LER-1980-111-03, /03L-0:on 801106,automatic Depressurization Sys Reactor Water Level Switch 1B21-N042A Actuated Above Tech Specs.Caused by Component Failure Due to Galling of Range Adjusting Screw.Level Switch Replaced + (ML19345B495)
- ML19345B496 + (ML19345B496)
- ML19345B499 + (ML19345B499)
- 05000271/LER-1980-039-03, /03L-0:on 801025,valves V16-20-20 & LRW-83 Found to Have Seat Leakage in Excess of Tech Specs.Cause Not Stated.Valves Repaired + (ML19345B502)
- ML19345B504 + (ML19345B504)
- ML19345B507 + (ML19345B507)
- ML19345B509 + (ML19345B509)
- ML19345B510 + (ML19345B510)
- ML19345B512 + (ML19345B512)
- ML19345B513 + (ML19345B513)
- ML19345B514 + (ML19345B514)
- ML19345B515 + (ML19345B515)
- ML19345B516 + (ML19345B516)
- ML19345B517 + (ML19345B517)
- ML19345B518 + (ML19345B518)
- ML19345B519 + (ML19345B519)
- ML19345B520 + (ML19345B520)
- ML19345B521 + (ML19345B521)
- 05000282/LER-1980-033, Forwards LER 80-033/03L-0 + (ML19345B523)
- ML19345B524 + (ML19345B524)
- ML19345B526 + (ML19345B526)
- 05000282/LER-1980-033-03, /03L-0:on 801028,steam Flow Transmitter 1FT-464 Observed Reading Low.Caused by Zero Adjustment Shift in Barton Model 384 Differential Pressure Transmitter.Device Recalibr + (ML19345B527)
- ML19345B528 + (ML19345B528)
- ML19345B529 + (ML19345B529)
- ML19345B530 + (ML19345B530)
- ML19345B531 + (ML19345B531)
- ML19345B532 + (ML19345B532)
- ML19345B533 + (ML19345B533)
- ML19345B534 + (ML19345B534)
- ML19345B536 + (ML19345B536)
- ML19345B538 + (ML19345B538)
- ML19345B540 + (ML19345B540)
- ML19345B541 + (ML19345B541)
- ML19345B544 + (ML19345B544)
- ML19345B545 + (ML19345B545)
- ML19345B546 + (ML19345B546)
- ML19345B547 + (ML19345B547)
- ML19345B549 + (ML19345B549)
- ML19345B550 + (ML19345B550)
- ML19345B555 + (ML19345B555)
- ML19345B556 + (ML19345B556)
- ML19345B557 + (ML19345B557)
- ML19345B558 + (ML19345B558)