- ML19344B043 + (ML19344B043)
- ML19344B045 + (ML19344B045)
- ML19344B046 + (ML19344B046)
- 05000346/LER-1980-059, Forwards LER 80-059/03L-0 + (ML19344B047)
- ML19344B048 + (ML19344B048)
- 05000346/LER-1980-059-03, /03L-0:on 800720,control Room Operators Noticed NI-1 Startup Rate Peg High,Then Low.Source Range Indication for NI-1 Went to Zero.Cause Not determined.Pre-amp Gain Link Readjusted to Raise Signal Pulses + (ML19344B049)
- 05000320/LER-1980-029, Forwards LER 80-029/01L-0 + (ML19344B052)
- 05000320/LER-1980-029-01, /01L-0:on 800714,during Recovery Mode Operation, Gray balance-of-plant Diesel Generator Failed to Start During Testing.Caused by Damaged Connection at Speed Sensor. Connection Repaired & Diesel Generator Testing Completed + (ML19344B055)
- ML19344B058 + (ML19344B058)
- 05000313/LER-1980-026, Forwards LER 80-026/03L-0 + (ML19344B059)
- ML19344B060 + (ML19344B060)
- 05000320/LER-1980-032, Forwards LER 80-032/03L-0 + (ML19344B063)
- ML19344B065 + (ML19344B065)
- ML19344B066 + (ML19344B066)
- ML19344B067 + (ML19344B067)
- ML19344B069 + (ML19344B069)
- 05000327/LER-1980-079, Forwards LER 80-079/03L-0 + (ML19344B070)
- ML19344B071 + (ML19344B071)
- 05000320/LER-1980-032-03, /03L-0:on 800719,during re-dewatering of EPICOR-I Liner,Leak of Radioactive Liquid Discovered.Caused by Worn Mating Surfaces of Quick Release Coupling.Requirements for Insp of Couplings Before & After Engagement Adopted + (ML19344B073)
- 05000327/LER-1980-079-03, /03L-0:on 800716,during Performance of Special Test 2,ice Bed Temp Exceeded Tech Spec Limit.Caused by Load Shedding Requirements of Special Maint Instruction 13.Glycol Cooling Sys Placed in Svc + (ML19344B077)
- ML19344B079 + (ML19344B079)
- ML19344B084 + (ML19344B084)
- ML19344B085 + (ML19344B085)
- 05000368/LER-1980-053-03, /03L-0:on 800721,CEAC 1 Failed During Mode 1 Operation.Cause Not Determined.Ceac Sys Software Reloaded, Periodic Tests Performed & Failure Indications Returned to Normal.Ceac Returned to Operable Status on All Channels + (ML19344B088)
- 05000368/LER-1980-054-03, /03L-0:on 800721,control Room Emergency Chiller 2VE-1B Found Inoperable During Mode 1 Operation.Caused by Unit Tripping on High Pressure Due to Improperly Operating Control Valve 2CV-1506-2.Control Valve Repaired + (ML19344B093)
- 05000368/LER-1980-055-03, /03L-0:on 800721,PPS Channel D Received Spurious Dnbr/Lpd Trips During Mode 1 Operation.Caused by Fluctuating CPC Dnbr/Lpd Temp Input Calculations.Temp Transmitter 2TT- 4711-4 Electrical Leads Checked & Tightened + (ML19344B098)
- 05000321/LER-1980-091, Forwards LER 80-091/03L-0 + (ML19344B108)
- ML19344B109 + (ML19344B109)
- ML19344B111 + (ML19344B111)
- 05000321/LER-1980-091-03, /03L-0:on 800724,while Performing Surveillance Procedure HNP-1-3974,control Room Air Intake Chlorine Monitor Calibr & Operability,Fan Motor on Monitor 1Z41-N022B Was Inoperative.Caused by Open Winding on Motor + (ML19344B115)
- ML19344B116 + (ML19344B116)
- 05000327/LER-1980-130, Forwards LER 80-130/03L-0 + (ML19344B118)
- ML19344B119 + (ML19344B119)
- 05000327/LER-1980-130-03, /03L-0:on 800709,during Mode 3 & Recovery from Scheduled Reactor Trip from Startup Testing,Differential Pressure Between Primary Containment & Annulus Exceeded Tech Spec Limit.Cause Not Apparent.Operators Instructed + (ML19344B124)
- ML19344B126 + (ML19344B126)
- ML19344B129 + (ML19344B129)
- ML19344B132 + (ML19344B132)
- ML19344B137 + (ML19344B137)
- A01151, Advises of Minor Adjustments to Evaluation Program Re Resolution of Cycle 3 Startup Commitments.Adjustments Are to Optimize Timetable for Critical Path Refueling Activities + (ML19344B139)
- 05000327/LER-1980-124, Forwards LER 80-124/03L-0 + (ML19344B141)
- ML19344B142 + (ML19344B142)
- ML19344B144 + (ML19344B144)
- 05000327/LER-1980-124-03, /03L-0:on 800719,during Low Power Testing in Mode 2,hydrogen Analyzer H2AN-43-200 Was Declared Inoperable Due to Low Sample Flow.Caused by Tripping of Sample Pump Motor Thermal Overload Due to Ambient Temp in Annulus + (ML19344B145)
- ML19344B146 + (ML19344B146)
- ML19344B147 + (ML19344B147)
- ML19344B148 + (ML19344B148)
- ML19344B151 + (ML19344B151)
- ML19344B152 + (ML19344B152)
- ML19344B153 + (ML19344B153)
- 05000368/LER-1980-051-03, /03L-0:on 800717,during Mode 1 Operation,Core a Protection Calculator Failure Alarm Was Received.Cause Not Determined.Calculator Reinitiated & All Failure Indications Returned to Normal.Bypasses Removed + (ML19344B154)
- ML19344B155 + (ML19344B155)