Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19326A065 + (ML19326A065)
- ML19326A066 + (ML19326A066)
- 05000346/LER-1978-083, Forwards LER 78-083/03L-0 + (ML19326A067)
- ML19326A068 + (ML19326A068)
- ML19326A069 + (ML19326A069)
- IR 05000244/2019410 + (ML19326A071)
- 05000346/LER-1978-085, Forwards LER 78-085/03L-0 + (ML19326A073)
- ML19326A074 + (ML19326A074)
- ML19326A075 + (ML19326A075)
- 05000346/LER-1978-085-03, /03L-0:on 780728,containment post-radiation Monitor Re 5029 Declared Inoperable.Caused by Component Failure.Motor Pulley Replaced & Belt Installed.Monitor Re 5029 Tested & Returned to Svc on 780801 + (ML19326A076)
- 05000346/LER-1978-073, Forwards LER 78-073/03L-0 + (ML19326A077)
- ML19326A078 + (ML19326A078)
- IR 07200828/2009001 + (ML19326A079)
- 05000346/LER-1978-073-03, /03L-0:on 780620,relay Wiring Error Found in Logic to Channel 2 Safety Features Actuation Sys.Caused by Mfg Defect:Relay Incorrectly Wired to Socket.Wiring Corrected & Verified by Surveillance Test 5031.07 + (ML19326A080)
- 05000346/LER-1978-075, Forwards LER 78-075/03L-0 + (ML19326A081)
- ML19326A082 + (ML19326A082)
- ML19326A083 + (ML19326A083)
- 05000346/LER-1978-074, Forwards LER 78-074/03L-0 + (ML19326A085)
- ML19326A086 + (ML19326A086)
- ML19326A087 + (ML19326A087)
- 05000346/LER-1978-074-03, /03L-0:on 780625,containment Isolation Valves CC 1407B & CC 1411B Failed to Operate When Automatically Actuated.Caused by Broken Wires,Probably Due to Strain Caused During Outage.Wires Repaired & Scheme Tested + (ML19326A088)
- 05000346/LER-1978-075-03, /03L-0:on 780629,radiation Monitor Re 5030 Found Inoperable.Caused by Component Failure.Motor Pulley Replaced & Belt Loosened.Monitor Declared Operable on 780630 + (ML19326A089)
- ML19326A090 + (ML19326A090)
- ML19326A092 + (ML19326A092)
- ML19326A093 + (ML19326A093)
- 05000346/LER-1978-076, Forwards LER 78-076/01T-0 + (ML19326A094)
- ML19326A095 + (ML19326A095)
- ML19326A096 + (ML19326A096)
- ML19326A098 + (ML19326A098)
- ML19326A099 + (ML19326A099)
- 05000346/LER-1978-076-01, /01T-0:on 780714,analysis Error Affecting Reactor Protection Sys Setpoints & RCS Operating Limits Found.Design Used Instead of Measured Coastdown Curve.New Setpoints Reviewed & Implemented.Amend to Tech Spec Being Prepared + (ML19326A101)
- IR 05000346/1974007 + (ML19326A102)
- ML19326A103 + (ML19326A103)
- 05000346/LER-1978-077, Forwards LER 78-077/03L-0 + (ML19326A104)
- ML19326A105 + (ML19326A105)
- ML19326A106 + (ML19326A106)
- ML19326A107 + (ML19326A107)
- ML19326A109 + (ML19326A109)
- ML19326A110 + (ML19326A110)
- ML19326A111 + (ML19326A111)
- 05000346/LER-1978-077-03, /03L-0:on 780710,component Cooling Water Pump Vibration Readings Exceeded Max Limits.Caused by Component Failure.Pump Bearings Found Failing.Bearing to Shell Clearance Increased & Pump Bearing Replaced + (ML19326A113)
- ML19326A114 + (ML19326A114)
- 05000346/LER-1978-078, Forwards LER 78-078/03L-0 + (ML19326A115)
- ML19326A116 + (ML19326A116)
- ML19326A117 + (ML19326A117)
- ML19326A120 + (ML19326A120)
- 05000346/LER-1978-078-03, /03L-0:on 780713,ST 5099.08 & ST 5099.11 Not Performed Per Tech Spec 4.0.5 & Not Included in Computer Schedule.St 5099.08 Incorporated in Test Program on 780727. Passive Valves Identified & Operational Log Used + (ML19326A121)
- ML19326A122 + (ML19326A122)
- ML19326A123 + (ML19326A123)
- ML19326A124 + (ML19326A124)
- ML19326A125 + (ML19326A125)