Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000366/LER-1980-013-03, /03L-0:on 800203,while Maint Was Performed on 2082-K002 Static Inverter,Emergency Control Transfer Switch Was Placed in Emergency Position.Reactor Core Isolation Cooling Was Rendered Inoperable.Caused by Personnel Error + (ML19296D179)
- 05000259/LER-1980-014-03, /03L-0:on 800126,during Refueling Outage,While Performing EMI-50,scram Accumulator Level Switch LS-1-85-34 for Control Rod Driveline 26-27 Would Not Give Annunciation for High Accumulator Level.Caused by Broken Reed Switch + (ML19296D180)
- 05000321/LER-1980-014, Forwards LER 80-014/03L-0 + (ML19296D181)
- ML19296D182 + (ML19296D182)
- 05000295/LER-1980-002-03, While in Cold Shutdown, Fire Sump Pump Radiation Monitor ORT-PR25 Was Bypassed Resulting in Failure of Fire Sump Pumps.Caused by Sand Accumulation in Sump.Sparger Sys Installed + (ML19296D183)
- ML19296D185 + (ML19296D185)
- 05000321/LER-1980-014-03, /03L-0:on 800130,during Steady State power,hi-low Flow Reactor Bldg Vent Stack Radiation Monitor Annunciator Alarm Occurred Because Gas Sample Flow Had Stopped.Caused by Solenoid Valve Stuck in Closed Position + (ML19296D186)
- 05000346/LER-1979-057, To LER 79-057/01T-1:on 790518,determined Some Hydraulic Snubbers May Not Have Fulfilled Functional Requirements.Caused by Improper Installation & Restrictive Performance Limits + (ML19296D187)
- ML19296D189 + (ML19296D189)
- 05000366/LER-1980-014, Forwards LER 80-014/03L-0 + (ML19296D190)
- ML19296D191 + (ML19296D191)
- 05000366/LER-1980-014-03, /03L-0:on 800204,while Performing HNP-2-3054, Average Power Range Monitor C Failed.Caused by Instrument Drift.Instrument Adjusted Per Procedure & Returned to Svc + (ML19296D194)
- ML19296D195 + (ML19296D195)
- ML19296D196 + (ML19296D196)
- 05000295/LER-1980-008, Forwards LER 80-008/01T-0 + (ML19296D197)
- IR 05000333/1979008 + (ML19296D199)
- 05000295/LER-1980-008-01, /01T-0:on 791204,in Constant Speed Drive,Unit 1 RCS Was Diluted W/Containment Integrity Violated.Dilution Controlled to Establish Shutdown Margin of Less than or Equal to 1%.Unit II Experienced Slow Dilution W/O Integrity + (ML19296D200)
- ML19296D203 + (ML19296D203)
- ML19296D205 + (ML19296D205)
- ML19296D206 + (ML19296D206)
- ML19296D207 + (ML19296D207)
- ML19296D208 + (ML19296D208)
- ML19296D209 + (ML19296D209)
- IR 05000317/1979016 + (ML19296D210)
- ML19296D211 + (ML19296D211)
- ML19296D212 + (ML19296D212)
- ML19296D214 + (ML19296D214)
- ML19296D215 + (ML19296D215)
- ML19296D216 + (ML19296D216)
- ML19296D217 + (ML19296D217)
- ML19296D219 + (ML19296D219)
- ML19296D220 + (ML19296D220)
- ML19296D221 + (ML19296D221)
- ML19296D222 + (ML19296D222)
- ML19296D223 + (ML19296D223)
- IR 05000317/1979013 + (ML19296D224)
- ML19296D225 + (ML19296D225)
- ML19296D226 + (ML19296D226)
- ML19296D228 + (ML19296D228)
- ML19296D229 + (ML19296D229)
- ML19296D231 + (ML19296D231)
- ML19296D232 + (ML19296D232)
- ML19296D233 + (ML19296D233)
- ML19296D234 + (ML19296D234)
- ML19296D236 + (ML19296D236)
- ML19296D238 + (ML19296D238)
- ML19296D240 + (ML19296D240)
- ML19296D241 + (ML19296D241)
- ML19296D242 + (ML19296D242)
- ML19296D243 + (ML19296D243)
- ML19296D244 + (ML19296D244)