- ML19250A473 + (ML19250A473)
- 05000334/LER-1979-038-03, /03L-0:on 790918,vital Bus Inverter 4 Output Frequency Observed Spiking Upscale.Caused by Faulty Oscillator Card in Inverter Control Logic.Inverter Repaired & Returned to Svc + (ML19250A474)
- ML19250A475 + (ML19250A475)
- ML19250A476 + (ML19250A476)
- ML19250A477 + (ML19250A477)
- ML19250A478 + (ML19250A478)
- 05000336/LER-1979-029, Forwards LER 79-029/03L-0 + (ML19250A479)
- ML19250A480 + (ML19250A480)
- ML19250A481 + (ML19250A481)
- ML19250A482 + (ML19250A482)
- ML19250A483 + (ML19250A483)
- ML19250A484 + (ML19250A484)
- ML19250A485 + (ML19250A485)
- ML19250A486 + (ML19250A486)
- 05000324/LER-1979-070, Forwards LER 79-070/03L-0 + (ML19250A487)
- ML19250A488 + (ML19250A488)
- 05000336/LER-1979-029-03, /03L-0:on 790919,B Hydrogen Analyzer Alarms Failed to Clear,Making Detection of Sensor Failure Impossible & Resulting in Hydrogen Analyzer Inoperability.Caused by Failure of Operational Amplifier in Alarm Card + (ML19250A489)
- ML19250A490 + (ML19250A490)
- ML19250A491 + (ML19250A491)
- 05000368/LER-1979-080-03, /03L-0:on 790921,indication for Sodium Hydroxide Addition Tank Discharge Valve 2CV-5667-2 Was Lost.Caused by Failed Power Supply Fuse.Power Fuse Was Replaced & Control Circuit Current Verified + (ML19250A492)
- ML19250A494 + (ML19250A494)
- 05000333/LER-1979-066, Forwards LER 79-066/03X-1 + (ML19250A495)
- ML19250A496 + (ML19250A496)
- ML19250A498 + (ML19250A498)
- 05000282/LER-1979-027-01, /01T-0:on 791002,tube Break Occurred in Steam Generator 11.Caused by Mechanical Wear.Two Defective Tubes Plugged + (ML19250A499)
- 05000333/LER-1979-066-03, /03X-1:on 790907,while Conducting Operations Surveillance Test,Average Power Range Monitor Channels A,D & F Tripped 0.5% Over Tech Spec Requirements.Caused by Operator Error.No Drift of Instrument Setpoint Occurred + (ML19250A500)
- 05000302/LER-1979-088, Forwards LER 79-088/03L-0 + (ML19250A501)
- ML19250A502 + (ML19250A502)
- ML19250A504 + (ML19250A504)
- TXX-3022, Forwards Itt Grinnell Engineering Std ES-13 in Response to IE Bulletin 79-02, Pipe Support Base Plate Designs Using Concrete Expansion Anchor Bolt + (ML19250A505)
- ML19250A506 + (ML19250A506)
- 05000302/LER-1979-088-03, /03L-0:on 790918,gaseous Release Monitor RMA-1 Was Found Isolated.Caused by Personnel Error.Monitor Not Properly Returned to Svc Following Filter Replacement. Revision Is Being Made + (ML19250A507)
- ML19250A509 + (ML19250A509)
- 05000333/LER-1979-077, Forwards LER 79-077/04L-0 + (ML19250A511)
- ML19250A512 + (ML19250A512)
- 05000324/LER-1979-070-03, /03L-0:on 790926,rod Drift Alarm Annunciated for Rod 22-31.Indication for Position Was No Longer Illuminated. Caused by Problem in Prototypic Inlet Piping Probe Located in Drywell + (ML19250A514)
- ML19250A516 + (ML19250A516)
- 05000333/LER-1979-077-04, /04L-0:on 790922,during Normal Operation,Shear Pins for Travelling Water Screens a & C Failed.Shear Pins Replaced & Normal Operation of Travelling Watering Screens Restored + (ML19250A517)
- ML19250A522 + (ML19250A522)
- ML19250A524 + (ML19250A524)
- 05000271/LER-1979-023, Forwards LER 79-023/03L-0 + (ML19250A525)
- ML19250A526 + (ML19250A526)
- ML19250A528 + (ML19250A528)
- ML19250A529 + (ML19250A529)
- ML19250A530 + (ML19250A530)
- 05000271/LER-1979-023-03, /03L-0:on 790919,LPCI Loop cross-tie Line Hanger Found Inadequate to Support Design Load.Caused by Improper Installation.Review of All Seismic Class I Sys Underway. Hanger Repaired W/New Anchor Bolts + (ML19250A532)
- ML19250A534 + (ML19250A534)
- ML19250A548 + (ML19250A548)
- ML19250A549 + (ML19250A549)
- ML19250A550 + (ML19250A550)
- ML19250A551 + (ML19250A551)