- 05000301/LER-1979-007-01, /01T-0:on 790929,main Steam Line B Isolation Valve Failed to Close During 20% Steam Flow,W/Unit Off Line.Caused Not Stated.Packing Was Loosened & Atwood Morrill Reverse Swing Check Valve Closed + (ML19209D123)
- ML19209D124 + (ML19209D124)
- ML19209D125 + (ML19209D125)
- ML19209D126 + (ML19209D126)
- 05000317/LER-1979-056, Forwards LER 79-056/03L-0 + (ML19209D127)
- ML19209D128 + (ML19209D128)
- ML19209D129 + (ML19209D129)
- ML19209D130 + (ML19209D130)
- 05000317/LER-1979-056-03, /03L-0:on 791001,output Voltage of Diesel Generator 11 Reached 4,800 Volts.Diesel Trip Occurred During Attempt to Lower Voltage.Caused by Loss of Calibr in Voltmeter Resistor.Resistor Replaced & Meter Recalibr + (ML19209D131)
- ML19209D132 + (ML19209D132)
- ML19209D133 + (ML19209D133)
- 05000293/LER-1979-038, Forwards LER 79-038/03L-0 + (ML19209D134)
- ML19209D135 + (ML19209D135)
- ML19209D136 + (ML19209D136)
- ML19209D137 + (ML19209D137)
- ML19209D138 + (ML19209D138)
- ML19209D139 + (ML19209D139)
- ML19209D140 + (ML19209D140)
- ML19209D142 + (ML19209D142)
- 05000293/LER-1979-038-03, /03L-0:on 791002,valve CV5065-26 Failed to Close in 5-s as Required by Tech Spec.Caused by Maladjusted Lever Arm Switch.Switch Adjustments Were Made & Valve Retimed within Limits + (ML19209D143)
- ML19209D144 + (ML19209D144)
- 05000251/LER-1979-015, Forwards LER 79-015/03L-0 + (ML19209D145)
- ML19209D146 + (ML19209D146)
- ML19209D147 + (ML19209D147)
- ML19209D148 + (ML19209D148)
- ML19209D149 + (ML19209D149)
- ML19209D150 + (ML19209D150)
- ML19209D151 + (ML19209D151)
- ML19209D152 + (ML19209D152)
- ML19209D153 + (ML19209D153)
- ML19209D154 + (ML19209D154)
- ML19209D155 + (ML19209D155)
- ML19209D157 + (ML19209D157)
- ML19209D158 + (ML19209D158)
- ML19209D159 + (ML19209D159)
- 05000346/LER-1979-028-03, /03L-1:on 790217,high Level Fail Alarm Received for Borated Water Storage Tank Level on Safety Features Actuation Sys Channel 1.Caused by Inadequate Insulation of Instrument Piping & Poor Location of Heat Trace Temp Sensor + (ML19209D160)
- ML19209D161 + (ML19209D161)
- ML19209D162 + (ML19209D162)
- ML19209D163 + (ML19209D163)
- 05000346/LER-1979-045-03, /03L-1:on 790330,borated Water Storage Tank Low Level Trip Setpoint in Safety Feature Actuation Sys Channel 2 Was Out of Tolerance.Caused by Noisy Constant Current Test Potentiometer.Potentiometer Replaced + (ML19209D164)
- ML19209D165 + (ML19209D165)
- ML19209D166 + (ML19209D166)
- ML19209D167 + (ML19209D167)
- ML19209D168 + (ML19209D168)
- ML19209D169 + (ML19209D169)
- ML19209D170 + (ML19209D170)
- ML19209D172 + (ML19209D172)