- 05000206/LER-1979-017-01, /01T-1:on 791107,following Loss of Power to Several Electrical Sys & 4 Kv Room Fire alarm,480-volt Bus Supply Breaker 1 Automatically Tripped.Caused by Rodent Bridging Two Energized phases,short-circuiting Bus + (ML13330A801)
- 05000206/LER-1979-018, Forwards LER 79-018/01T-0 + (ML13330A802)
- 05000206/LER-1979-018-01, /01T-0:on 791109,support Discovered Missing on Liquid Radwaste Disposal Sys Piping Outside Containment. Caused by Failure to Install Support During Field Const. New Support Installed During 791110 Unrelated Outage + (ML13330A805)
- ML13330A806 + (ML13330A806)
- ML13330A807 + (ML13330A807)
- 05000206/LER-1979-020, Forwards LER 79-020/01T-0 + (ML13330A808)
- 05000206/LER-1979-020-01, /01T-0:on 791126,missing Valve Operator Support & Incorrectly Welded Valve Operator Support Discovered During Inspection.Caused by Poor Const.New Support Configuration Conforms Piping Sys to Seismic Input Info + (ML13330A810)
- 05000206/LER-1979-023, Forwards LER 79-023/03L-0 + (ML13330A812)
- 05000206/LER-1979-023-03, /03L-0:on 791010,during QA Audit,Variable Low Pressure Trip Setting on Pressure Channel Not Equal to Prescribed Computed Trip Value.Caused by Test Procedure Not Containing Acceptance Criteria.Procedure Revised + (ML13330A814)
- 05000206/LER-1979-019, Forwards LER 79-019/01T-0 + (ML13330A817)
- 05000206/LER-1979-019-01, /01T-0:on 791116,during Field Verification/Insp, Three Supports Were Missing on Piping Used to Transfer Fuel to Diesel Generator.Supports Were Not Installed During Const.New Supports Installed on 791116 + (ML13330A819)
- 05000206/LER-1979-021, Forwards LER 79-021/01T-0 + (ML13330A820)
- 05000206/LER-1979-021-01, /01T-0:on 791114,while Making Routine Rounds, Operator Found 15 Volt Dc Power Supply on Y Subchannel of Load Sequencer Number 2 Had Tripped Off.Cause Unknown.Power Supply Reset & Sequencer Sucessfully Tested + (ML13330A822)
- ML13330A823 + (ML13330A823)
- ML13330A824 + (ML13330A824)
- ML13330A825 + (ML13330A825)
- ML13330A827 + (ML13330A827)
- 05000206/LER-1979-022-01, /01T-0:on 791130,supports on Component Cooling Water Sys Supply Header Found Missing.Supports Not Installed During Field Const.New Supports Installed 791202,conforming Piping Sys to Seismic Analysis Input Info + (ML13330A828)
- 05000206/LER-1979-017, Forwards Revised Chronology of Events for LER 79-017, Revision 1 Re Failure of 480-volt Bus 1.Change Basically Concerns Util Internal Communications + (ML13330A830)
- 05000206/LER-1979-025, Forwards LER 79-025/03L-0 + (ML13330A831)
- 05000206/LER-1979-025-03, /03L-0:on 791011,during Normal Operation,Loop C Variable Low Pressure Scram Setpoint Failed in Nonconservative Direction.Caused by Failure of Capacitor in Loop C T-ave R/I Converter.Capacitor Replaced + (ML13330A833)
- 05000206/LER-1979-026, Forwards LER 79-026/03L-0 + (ML13330A834)
- 05000206/LER-1979-026-03, /03L-0:on 791226,during Test of Steam Driven Auxiliary Feedwater Pump,Pump Inboard Bearing Overheated & Failed.Caused by Lack of Lubrication.Review of Bearing Lubrication Sys Will Be Initiated + (ML13330A837)
- ML13330A839 + (ML13330A839)
- 05000206/LER-1980-002, Forwards LER 80-002/01T-0 + (ML13330A840)
- 05000206/LER-1980-002-01, /01T-0:on 800116,during Normal Operation,While Installing TMI Project Instrumentation,Auxiliary Relay Tripped & Shut East Feedwater Pump Discharge Valve, Resulting in Turbine Trip.Caused by Worker Bumping Relay + (ML13330A842)
- 05000206/LER-1979-024, Forwards LER 79-024/03L-0 + (ML13330A843)
- 05000206/LER-1979-024-03, /03L-0:on 791203,during Normal Operations,Mods Involving Instrumentation on Feedwater Flow Orifices & Steam Generator hi-lo Level Alarms Discovered Made W/O Approved Design Change.Caused by Failure to Follow Procedure + (ML13330A845)
- 05000206/LER-1980-001, Forwards LER 80-001/01T-0 + (ML13330A847)
- 05000206/LER-1980-001-01, /01T-0:on 800110,during Field Verification Per IE Bulletin 79-14,found Supporting Configurations on Letdown Line & Turbine Plant Cooling Water Supply Line Not Installed as Assumed in Seismic Stress Analysis.Cause Not Stated + (ML13330A850)
- 05000206/LER-1980-003, Forwards LER 80-003/03L-0 + (ML13330A852)
- 05000206/LER-1980-003-03, /03L-0:on 800109,during Normal Operations,While Performing Containment Isolation Valve Test CV-537,isolation Valve for Svc Water to Containment Failed to Close.Caused by Small Particles of Desiccant in Air Lines + (ML13330A854)
- ML13330A856 + (ML13330A856)
- ML13330A857 + (ML13330A857)
- BVY 13-100, Response to Request for Additional Information Pursuant to 10 CFR 50.54(f) Regarding the Seismic Hazard Walkdowns Conducted to Verify Current Plant Compliance with the Current Licensing Basis (CLB) for Seismic Requirements + (ML13330A859)
- ML13330A860 + (ML13330A860)
- BVY 13-101, Entergys Request for Rescission of and Schedule Relief from Commission Order Modifying License with Regard to Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions (Order Number EA-13-109) + (ML13330A861)
- ML13330A862 + (ML13330A862)