Browse wiki
Jump to navigation
Jump to search
IWB-2500 +, IWC-5220 +, IWC-2500 +, IWC-5222 +, IWB-5000 +, IWB-2000 +, IWC-5000 +, IWB-5220 +, IWB-1220 +, IWC-1220 +, IWC-2430 +, IWB-1200 +, IWB-2430 +, IWC-2000 +, IWB-3517 +, IWA-6000 +, IWA-2300 +, IWA-4700 +, IWA-5000 +, IWA-4400 +, IWA-5244 +, IWA-5211 +, IWA-1400 +, IWA-2430 +, IWA-2240 +, IWA-2314 +, IWA-2200 +, IWA-5242 +, IWA-4520 +, IWA-4521 +...
ML12275A070 +
BWRVIP-75-A +, BWRVIP-75 +, BWRVIP-94 +, BWRVIP-25 +, BWRVIP-138 +, BWRVIP-03 +, BWRVIP-183 +, BWRVIP-18 +, BWRVIP-38 +, BWRVIP-76 +, BWRVIP-05 +, BWRVIP-26-A +, BWRVIP-27-A +, BWRVIP-47-A +, BWRVIP-48-A + and BWRVIP-76-A +
10 CFR 50 Appendix J +, 10 CFR 50.2 +, 10 CFR 50.55a +, 10 CFR 50.65#a4 +, 10 CFR 50.55a#g +, 10 CFR 50.55a#g5iii +, 10 CFR 50.55a#a3i +, 10 CFR 50.55a#a3 +, 10 CFR 50.55a#g4 +, 10 CFR 50.55a#g6i +, 10 CFR 50.55a#a3ii +, 10 CFR 50.55a#b2 +, 10 CFR 50.55a#b2xiv +, 10 CFR 50.55a#b2ixG +, 10 CFR 50.55a#b2ixA +, 10 CFR 50.55a#b2ixB +, 10 CFR 50.55a#b2ixF +, 10 CFR 50.55a#b2ixH +, 10 CFR 50.55a#b2ixI +, 10 CFR 50.55a#b3 +, 10 CFR 50.55a#g4ii +, 10 CFR 50.55a#g6iiB +, 10 CFR 50.55a#b5 +, 10 CFR 50.55a#b2xxiv +, 10 CFR 50.55a#b2xxB +, 10 CFR 50.55a#b2xix +, 10 CFR 50.55a#g4v +, 10 CFR 50.55a#b2xxv +, 10 CFR 50.55a#b2xxvi +, 10 CFR 50.55a#b2x +...
ASME Code Case N-513-3 +, ASME Code Case N-638-4 +, ASME Code Case N-661-1 +, ASME Code Case N-597-2 +, ASME Code Case N-578-1 +, ASME Code Case OMN-13 +, ASME Code Case N-613-1 +, ASME Code Case N-532-4 +, ASME Code Case N-789 +, ASME Code Case N-639 +, ASME Code Case N-516-3 +, ASME Code Case N-606-1 +, ASME Code Case N-751 +, ASME Code Case N-62-7 + and ASME Code Case N-405-1 +
ML113620684 +, ML11271A058 +, ML080220433 +, ML080980311 +, ML120180372 +, ML120370286 +, ML11195A182 + and ML090760986 +
Exelon + and David Gullott +
NRC Generic Letter 88-01, NRC Position on Intergranular Stress Corrosion Cracking (IGSCC) in BWR Austenitic Stainless Steel Piping + and NRC Generic Letter 98-05, Boiling Water Reactor Licensees Use of the BWRVIP-05 Report to Request Relief from Augmented Examination Requirements on Reactor Pressure Vessel Circumferential Shell Welds +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +, RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +, RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +, RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +, RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +, RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +, RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +, RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +, RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +, RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +, RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +, RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +, RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +, RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +, RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +, RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +, RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +, RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +, RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +, RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +, RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +, RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +, RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +, RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +, RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +, RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +, RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +, RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +, RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +, RS-12-150, Fifth Interval Inservice Inspection Program Plan and Relief Requests +...
September 28, 2012 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
03:15:19, 12 January 2025 +
NUREG-0619, Informs That Staff Finds PP&L 980330 Request for Relief from Requirements of Section 4.3 of NUREG-0619,exams of Feedwater Nozzle Bore & Inner Radius for Another Operating Cycle to Be Acceptable +, NUREG-0313, Safety Evaluation Supporting Amend 133 to License DPR-59 +, NUREG-0737, To NUREG-0737, Request for Extension of Time for Commission Order Dated June 14, 1984 +, NUREG-1801, Proprosed Revision of Chapters II & III of Generic Aging Lessons (Gall) Report on Aging Management of Concrete Elements + and NUREG-1796, (2:2) Chpt 3 - End, Safety Evaluation Report: Related to the License Renewal of Dresden Nuclear Power Station, Units 2 & 3 and Quad Cities Nuclear Power Station, Units 1 & 2 +
180 +
Processing error"Processing error" is a predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> and represents errors that appeared in connection with improper value annotations or input processing.
TAC:MA6787 +, TAC:MA9891 +, TAC:ME2189 +, TAC:MD5352 +, TAC:MB0844 +, TAC:MB0842 +, TAC:ME5373 +, TAC:MB0484 +, TAC:ME6765 +, TAC:MA5012 +, TAC:MA6228 +, TAC:MC2190 +, TAC:MB0721 +, TAC:M93925 +, TAC:M99638 + and TAC:M94090 +
Request +
I3R-09 +, 02B-S7 +, I5R-07 +, I4R-05 +, I4R-06 +, I4R-07 +, I4R-09 +, I4R-03 +, I5R-08 +, 15R-08 +, I4R-01 +, 202L-R2 +, I5R-02 +, I5R-04 +, I5R-03 +, 15R-07 +, I4R-10 +, I4R-02 +, I3R-01 +, I3R-03 +, 15R-01 +, 15R-09 +, 15R-10 +, 15R-05 +, I5R-01 +, I5R-05 +, I5R-10 +, I5R-06 +, I5R-09 +, I4R-18 +...
September 28, 2012 +
Feedwater +, Service water +, High Pressure Coolant Injection +, Reactor Core Isolation Cooling +, Primary containment +, HVAC +, Reactor Pressure Vessel +, Core Spray +, Residual Heat Removal +, Reactor Water Cleanup +, Standby Liquid Control +, Residual Heat Removal Service Water +, Emergency Core Cooling System +, Control rod blade +, Control Rod + and Main Steam +
Safe Shutdown +, Non-Destructive Examination +, Mission time +, Weld Overlay +, Internal Flooding +, Hydrostatic +, Probabilistic Risk Assessment +, Nondestructive Examination +, VT-2 +, Incorporated by reference +, Aging Management +, Flow Accelerated Corrosion +, Intergranular Stress Corrosion Cracking +, Stress corrosion cracking +, Moisture barrier +, License Renewal +, EVT-1 +, Dissimilar Metal Weld +, Power Uprate + and Thermal fatigue +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.