Browse wiki
Jump to navigation
Jump to search
ML17228A134 +
10 CFR 50 + and 10 CFR 50.4 +
Sager D + and NextEra Energy +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
L-93-101, Forwards Modified Relief Request VR-22 for Check Valves V-07269 & V-07270 for Approval.Util Has Determined Per 10CFR50.a(a)(3) That Proposed Alternatives Would Provide Acceptable Level of Quality & Safety +, L-93-101, Forwards Modified Relief Request VR-22 for Check Valves V-07269 & V-07270 for Approval.Util Has Determined Per 10CFR50.a(a)(3) That Proposed Alternatives Would Provide Acceptable Level of Quality & Safety +, L-93-101, Forwards Modified Relief Request VR-22 for Check Valves V-07269 & V-07270 for Approval.Util Has Determined Per 10CFR50.a(a)(3) That Proposed Alternatives Would Provide Acceptable Level of Quality & Safety +, L-93-101, Forwards Modified Relief Request VR-22 for Check Valves V-07269 & V-07270 for Approval.Util Has Determined Per 10CFR50.a(a)(3) That Proposed Alternatives Would Provide Acceptable Level of Quality & Safety +, L-93-101, Forwards Modified Relief Request VR-22 for Check Valves V-07269 & V-07270 for Approval.Util Has Determined Per 10CFR50.a(a)(3) That Proposed Alternatives Would Provide Acceptable Level of Quality & Safety +, L-93-101, Forwards Modified Relief Request VR-22 for Check Valves V-07269 & V-07270 for Approval.Util Has Determined Per 10CFR50.a(a)(3) That Proposed Alternatives Would Provide Acceptable Level of Quality & Safety +, L-93-101, Forwards Modified Relief Request VR-22 for Check Valves V-07269 & V-07270 for Approval.Util Has Determined Per 10CFR50.a(a)(3) That Proposed Alternatives Would Provide Acceptable Level of Quality & Safety +, L-93-101, Forwards Modified Relief Request VR-22 for Check Valves V-07269 & V-07270 for Approval.Util Has Determined Per 10CFR50.a(a)(3) That Proposed Alternatives Would Provide Acceptable Level of Quality & Safety +, L-93-101, Forwards Modified Relief Request VR-22 for Check Valves V-07269 & V-07270 for Approval.Util Has Determined Per 10CFR50.a(a)(3) That Proposed Alternatives Would Provide Acceptable Level of Quality & Safety + and L-93-101, Forwards Modified Relief Request VR-22 for Check Valves V-07269 & V-07270 for Approval.Util Has Determined Per 10CFR50.a(a)(3) That Proposed Alternatives Would Provide Acceptable Level of Quality & Safety +
April 19, 1993 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
18:52:28, 8 January 2025 +
6 +
Request +
April 19, 1993 +
Florida + and Washington +
Forwards Modified Relief Request VR-22 for Check Valves V-07269 & V-07270 for Approval.Util Has Determined Per 10CFR50.a(a)(3) That Proposed Alternatives Would Provide Acceptable Level of Quality & Safety +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.