Browse wiki
Jump to navigation
Jump to search
ML15005A045 +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +, 05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +, 05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +, 05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +, 05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +, 05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +, 05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +, 05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +, 05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +, 05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +, 05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +, 05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +, 05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +, 05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +, 05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +, 05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +, 05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +, 05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +, 05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +, 05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +, 05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +, 05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +, 05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +, 05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +, 05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +, 05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +, 05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +, 05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +, 05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +, 05000529/LER-2014-002, Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +...
December 30, 2014 +
2 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
20:08:33, 10 January 2025 +
6 +
Processing error"Processing error" is a predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> and represents errors that appeared in connection with improper value annotations or input processing.
Request +
10 CFR 50.73(a)(2)(iv)(A), System Actuation +, 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition +, 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor +, 10 CFR 50.73(a)(2)(v), Loss of Safety Function +, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability +, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications +, 10 CFR 50.73(a)(2)(i) +, 10 CFR 50.73(a)(2)(x) +, 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded +, 10 CFR 50.73(a)(2)(iii) +, 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown +, 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System +, 10 CFR 50.73(a)(2)(viii)(A) + and 10 CFR 50.73(a)(2)(viii)(B) +
December 30, 2014 +
Washington + and Arizona +
Regarding Technical Specification (TS) Required Plant Shutdown Due to a Dropped Control Element Assembly +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.