ML19273C695 +
Schaefer M + and South Texas +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000498/LER-2019-002, Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves +, 05000498/LER-2019-002, Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves +, 05000498/LER-2019-002, Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves +, 05000498/LER-2019-002, Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves +, 05000498/LER-2019-002, Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves +, 05000498/LER-2019-002, Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves +, 05000498/LER-2019-002, Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves +, 05000498/LER-2019-002, Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves +, 05000498/LER-2019-002, Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves +, 05000498/LER-2019-002, Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves +, 05000498/LER-2019-002, Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves +, 05000498/LER-2019-002, Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves +, 05000498/LER-2019-002, Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves +, 05000498/LER-2019-002, Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves +, 05000498/LER-2019-002, Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves +, 05000498/LER-2019-002, Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves +, 05000498/LER-2019-002, Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves +, 05000498/LER-2019-002, Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves +, 05000498/LER-2019-002, Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves +, 05000498/LER-2019-002, Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves +, 05000498/LER-2019-002, Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves +, 05000498/LER-2019-002, Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves +, 05000498/LER-2019-002, Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves +, 05000498/LER-2019-002, Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves +, 05000498/LER-2019-002, Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves +, 05000498/LER-2019-002, Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves +, 05000498/LER-2019-002, Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves +, 05000498/LER-2019-002, Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves + and 05000498/LER-2019-002, Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves +
September 30, 2019 +
2 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
10:15:55, 3 January 2025 +
7 +
Request +
10 CFR 50.73(a)(2)(iv)(A), System Actuation +, 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition +, 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor +, 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat +, 10 CFR 50.73(a)(2)(v), Loss of Safety Function +, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability +, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications +, 10 CFR 50.73(a)(2)(i) +, 10 CFR 50.73(a)(2)(x) +, 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded +, 10 CFR 50.73(a)(2)(iii) +, 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown +, 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System +, 10 CFR 50.73(a)(2)(viii)(A) + and 10 CFR 50.73(a)(2)(viii)(B) +
September 30, 2019 +
Texas + and Washington +
Condition Prohibited by Technical Specifications and Loss of Safety Function Due to Inoperable Reactor Head Vent Throttle Valves +