Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000423/LER-2016-001, Regarding Automatic Reactor Trip on Reactor Coolant System Low Flow Due to Loss of B Reactor Coolant Pump +, 05000423/LER-2016-001, Regarding Automatic Reactor Trip on Reactor Coolant System Low Flow Due to Loss of B Reactor Coolant Pump +, 05000423/LER-2016-001, Regarding Automatic Reactor Trip on Reactor Coolant System Low Flow Due to Loss of B Reactor Coolant Pump +, 05000423/LER-2016-001, Regarding Automatic Reactor Trip on Reactor Coolant System Low Flow Due to Loss of B Reactor Coolant Pump +, 05000423/LER-2016-001, Regarding Automatic Reactor Trip on Reactor Coolant System Low Flow Due to Loss of B Reactor Coolant Pump +, 05000423/LER-2016-001, Regarding Automatic Reactor Trip on Reactor Coolant System Low Flow Due to Loss of B Reactor Coolant Pump +, 05000423/LER-2016-001, Regarding Automatic Reactor Trip on Reactor Coolant System Low Flow Due to Loss of B Reactor Coolant Pump +, 05000423/LER-2016-001, Regarding Automatic Reactor Trip on Reactor Coolant System Low Flow Due to Loss of B Reactor Coolant Pump +, 05000423/LER-2016-001, Regarding Automatic Reactor Trip on Reactor Coolant System Low Flow Due to Loss of B Reactor Coolant Pump +, 05000423/LER-2016-001, Regarding Automatic Reactor Trip on Reactor Coolant System Low Flow Due to Loss of B Reactor Coolant Pump +, 05000423/LER-2016-001, Regarding Automatic Reactor Trip on Reactor Coolant System Low Flow Due to Loss of B Reactor Coolant Pump +, 05000423/LER-2016-001, Regarding Automatic Reactor Trip on Reactor Coolant System Low Flow Due to Loss of B Reactor Coolant Pump +, 05000423/LER-2016-001, Regarding Automatic Reactor Trip on Reactor Coolant System Low Flow Due to Loss of B Reactor Coolant Pump +, 05000423/LER-2016-001, Regarding Automatic Reactor Trip on Reactor Coolant System Low Flow Due to Loss of B Reactor Coolant Pump +, 05000423/LER-2016-001, Regarding Automatic Reactor Trip on Reactor Coolant System Low Flow Due to Loss of B Reactor Coolant Pump +, 05000423/LER-2016-001, Regarding Automatic Reactor Trip on Reactor Coolant System Low Flow Due to Loss of B Reactor Coolant Pump +, 05000423/LER-2016-001, Regarding Automatic Reactor Trip on Reactor Coolant System Low Flow Due to Loss of B Reactor Coolant Pump +, 05000423/LER-2016-001, Regarding Automatic Reactor Trip on Reactor Coolant System Low Flow Due to Loss of B Reactor Coolant Pump +, 05000423/LER-2016-001, Regarding Automatic Reactor Trip on Reactor Coolant System Low Flow Due to Loss of B Reactor Coolant Pump +, 05000423/LER-2016-001, Regarding Automatic Reactor Trip on Reactor Coolant System Low Flow Due to Loss of B Reactor Coolant Pump +, 05000423/LER-2016-001, Regarding Automatic Reactor Trip on Reactor Coolant System Low Flow Due to Loss of B Reactor Coolant Pump +, 05000423/LER-2016-001, Regarding Automatic Reactor Trip on Reactor Coolant System Low Flow Due to Loss of B Reactor Coolant Pump +, 05000423/LER-2016-001, Regarding Automatic Reactor Trip on Reactor Coolant System Low Flow Due to Loss of B Reactor Coolant Pump +, 05000423/LER-2016-001, Regarding Automatic Reactor Trip on Reactor Coolant System Low Flow Due to Loss of B Reactor Coolant Pump +, 05000423/LER-2016-001, Regarding Automatic Reactor Trip on Reactor Coolant System Low Flow Due to Loss of B Reactor Coolant Pump +, 05000423/LER-2016-001, Regarding Automatic Reactor Trip on Reactor Coolant System Low Flow Due to Loss of B Reactor Coolant Pump + and 05000423/LER-2016-001, Regarding Automatic Reactor Trip on Reactor Coolant System Low Flow Due to Loss of B Reactor Coolant Pump +
March 16, 2016 +
1 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
07:18:51, 10 January 2025 +
6 +
Request +
10 CFR 50.73(a)(2)(iv)(A), System Actuation +, 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition +, 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor +, 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat +, 10 CFR 50.73(a)(2)(v), Loss of Safety Function +, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability +, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications +, 10 CFR 50.73(a)(2)(i) +, 10 CFR 50.73(a)(2)(x) +, 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded +, 10 CFR 50.73(a)(2)(iii) + and 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown +
March 16, 2016 +
Connecticut + and Washington +
Regarding Automatic Reactor Trip on Reactor Coolant System Low Flow Due to Loss of B Reactor Coolant Pump +