Browse wiki
Jump to navigation
Jump to search
ML20132G151 +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000423/LER-1996-028, :on 960916,potential Overcooling of Charging Pump Lube Oil Sys Occurred Due to Failure of air-operated Temperature Control Valves.Temporary Mod to Limit Failure Position of Three Way Cce Temp Control Valve,Installed +, 05000423/LER-1996-028, :on 960916,potential Overcooling of Charging Pump Lube Oil Sys Occurred Due to Failure of air-operated Temperature Control Valves.Temporary Mod to Limit Failure Position of Three Way Cce Temp Control Valve,Installed +, 05000423/LER-1996-028, :on 960916,potential Overcooling of Charging Pump Lube Oil Sys Occurred Due to Failure of air-operated Temperature Control Valves.Temporary Mod to Limit Failure Position of Three Way Cce Temp Control Valve,Installed +, 05000423/LER-1996-028, :on 960916,potential Overcooling of Charging Pump Lube Oil Sys Occurred Due to Failure of air-operated Temperature Control Valves.Temporary Mod to Limit Failure Position of Three Way Cce Temp Control Valve,Installed +, 05000423/LER-1996-028, :on 960916,potential Overcooling of Charging Pump Lube Oil Sys Occurred Due to Failure of air-operated Temperature Control Valves.Temporary Mod to Limit Failure Position of Three Way Cce Temp Control Valve,Installed +, 05000423/LER-1996-028, :on 960916,potential Overcooling of Charging Pump Lube Oil Sys Occurred Due to Failure of air-operated Temperature Control Valves.Temporary Mod to Limit Failure Position of Three Way Cce Temp Control Valve,Installed +, 05000423/LER-1996-028, :on 960916,potential Overcooling of Charging Pump Lube Oil Sys Occurred Due to Failure of air-operated Temperature Control Valves.Temporary Mod to Limit Failure Position of Three Way Cce Temp Control Valve,Installed +, 05000423/LER-1996-028, :on 960916,potential Overcooling of Charging Pump Lube Oil Sys Occurred Due to Failure of air-operated Temperature Control Valves.Temporary Mod to Limit Failure Position of Three Way Cce Temp Control Valve,Installed +, 05000423/LER-1996-028, :on 960916,potential Overcooling of Charging Pump Lube Oil Sys Occurred Due to Failure of air-operated Temperature Control Valves.Temporary Mod to Limit Failure Position of Three Way Cce Temp Control Valve,Installed +, 05000423/LER-1996-028, :on 960916,potential Overcooling of Charging Pump Lube Oil Sys Occurred Due to Failure of air-operated Temperature Control Valves.Temporary Mod to Limit Failure Position of Three Way Cce Temp Control Valve,Installed +, 05000423/LER-1996-028, :on 960916,potential Overcooling of Charging Pump Lube Oil Sys Occurred Due to Failure of air-operated Temperature Control Valves.Temporary Mod to Limit Failure Position of Three Way Cce Temp Control Valve,Installed +, 05000423/LER-1996-028, :on 960916,potential Overcooling of Charging Pump Lube Oil Sys Occurred Due to Failure of air-operated Temperature Control Valves.Temporary Mod to Limit Failure Position of Three Way Cce Temp Control Valve,Installed + and 05000423/LER-1996-028, :on 960916,potential Overcooling of Charging Pump Lube Oil Sys Occurred Due to Failure of air-operated Temperature Control Valves.Temporary Mod to Limit Failure Position of Three Way Cce Temp Control Valve,Installed +
December 13, 1996 +
28 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
15:21:40, 25 May 2025 +
4 +
Processing error"Processing error" is a predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> and represents errors that appeared in connection with improper value annotations or input processing.
Request +
December 13, 1996 +
:on 960916,potential Overcooling of Charging Pump Lube Oil Sys Occurred Due to Failure of air-operated Temperature Control Valves.Temporary Mod to Limit Failure Position of Three Way Cce Temp Control Valve,Installed
+
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.