Browse wiki
Jump to navigation
Jump to search
ML052920061 +
Jefferson W + and NextEra Energy +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000389/LER-2005-003, Re Personnel Error Caused Partial Loss of Feedwater and Manual Reactor Trip +, 05000389/LER-2005-003, Re Personnel Error Caused Partial Loss of Feedwater and Manual Reactor Trip +, 05000389/LER-2005-003, Re Personnel Error Caused Partial Loss of Feedwater and Manual Reactor Trip +, 05000389/LER-2005-003, Re Personnel Error Caused Partial Loss of Feedwater and Manual Reactor Trip +, 05000389/LER-2005-003, Re Personnel Error Caused Partial Loss of Feedwater and Manual Reactor Trip +, 05000389/LER-2005-003, Re Personnel Error Caused Partial Loss of Feedwater and Manual Reactor Trip +, 05000389/LER-2005-003, Re Personnel Error Caused Partial Loss of Feedwater and Manual Reactor Trip +, 05000389/LER-2005-003, Re Personnel Error Caused Partial Loss of Feedwater and Manual Reactor Trip +, 05000389/LER-2005-003, Re Personnel Error Caused Partial Loss of Feedwater and Manual Reactor Trip +, 05000389/LER-2005-003, Re Personnel Error Caused Partial Loss of Feedwater and Manual Reactor Trip +, 05000389/LER-2005-003, Re Personnel Error Caused Partial Loss of Feedwater and Manual Reactor Trip +, 05000389/LER-2005-003, Re Personnel Error Caused Partial Loss of Feedwater and Manual Reactor Trip +, 05000389/LER-2005-003, Re Personnel Error Caused Partial Loss of Feedwater and Manual Reactor Trip +, 05000389/LER-2005-003, Re Personnel Error Caused Partial Loss of Feedwater and Manual Reactor Trip +, 05000389/LER-2005-003, Re Personnel Error Caused Partial Loss of Feedwater and Manual Reactor Trip +, 05000389/LER-2005-003, Re Personnel Error Caused Partial Loss of Feedwater and Manual Reactor Trip +, 05000389/LER-2005-003, Re Personnel Error Caused Partial Loss of Feedwater and Manual Reactor Trip +, 05000389/LER-2005-003, Re Personnel Error Caused Partial Loss of Feedwater and Manual Reactor Trip +, 05000389/LER-2005-003, Re Personnel Error Caused Partial Loss of Feedwater and Manual Reactor Trip +, 05000389/LER-2005-003, Re Personnel Error Caused Partial Loss of Feedwater and Manual Reactor Trip +, 05000389/LER-2005-003, Re Personnel Error Caused Partial Loss of Feedwater and Manual Reactor Trip +, 05000389/LER-2005-003, Re Personnel Error Caused Partial Loss of Feedwater and Manual Reactor Trip +, 05000389/LER-2005-003, Re Personnel Error Caused Partial Loss of Feedwater and Manual Reactor Trip +, 05000389/LER-2005-003, Re Personnel Error Caused Partial Loss of Feedwater and Manual Reactor Trip +, 05000389/LER-2005-003, Re Personnel Error Caused Partial Loss of Feedwater and Manual Reactor Trip +, 05000389/LER-2005-003, Re Personnel Error Caused Partial Loss of Feedwater and Manual Reactor Trip +, 05000389/LER-2005-003, Re Personnel Error Caused Partial Loss of Feedwater and Manual Reactor Trip +, 05000389/LER-2005-003, Re Personnel Error Caused Partial Loss of Feedwater and Manual Reactor Trip + and 05000389/LER-2005-003, Re Personnel Error Caused Partial Loss of Feedwater and Manual Reactor Trip +
0.0121 d (0.291 hours, 0.00173 weeks, 3.98764e-4 months) +, 0.0155 d (0.372 hours, 0.00222 weeks, 5.0987e-4 months) +, 0.0203 d (0.487 hours, 0.0029 weeks, 6.66636e-4 months) +, 0.0109 d (0.262 hours, 0.00156 weeks, 3.59192e-4 months) + and 0.00116 d (0.0278 hours, 1.653439e-4 weeks, 3.805e-5 months) +
October 10, 2005 +
3 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
19:34:01, 15 January 2025 +
4 +
Request +
10 CFR 50.73(a)(2)(iv)(A), System Actuation +, 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition +, 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor +, 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat +, 10 CFR 50.73(a)(2)(v), Loss of Safety Function +, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability +, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications +, 10 CFR 50.73(a)(2)(i) +, 10 CFR 50.73(a)(2)(x) +, 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded +, 10 CFR 50.73(a)(2)(iii) +, 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown +, 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System +, 10 CFR 50.73(a)(2)(viii)(A) + and 10 CFR 50.73(a)(2)(viii)(B) +
October 10, 2005 +
Florida + and Washington +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.