Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000389/LER-1987-006-03, :on 870917,discovered That Test of Emergency Diesel Generator Automatic Load Sequence Relays Incomplete. Caused by Personnel Error.Personnel Immediately Performed Required Surveillance Test Per Procedure +, 05000389/LER-1987-006-03, :on 870917,discovered That Test of Emergency Diesel Generator Automatic Load Sequence Relays Incomplete. Caused by Personnel Error.Personnel Immediately Performed Required Surveillance Test Per Procedure +, 05000389/LER-1987-006-03, :on 870917,discovered That Test of Emergency Diesel Generator Automatic Load Sequence Relays Incomplete. Caused by Personnel Error.Personnel Immediately Performed Required Surveillance Test Per Procedure +, 05000389/LER-1987-006-03, :on 870917,discovered That Test of Emergency Diesel Generator Automatic Load Sequence Relays Incomplete. Caused by Personnel Error.Personnel Immediately Performed Required Surveillance Test Per Procedure +, 05000389/LER-1987-006-03, :on 870917,discovered That Test of Emergency Diesel Generator Automatic Load Sequence Relays Incomplete. Caused by Personnel Error.Personnel Immediately Performed Required Surveillance Test Per Procedure +, 05000389/LER-1987-006-03, :on 870917,discovered That Test of Emergency Diesel Generator Automatic Load Sequence Relays Incomplete. Caused by Personnel Error.Personnel Immediately Performed Required Surveillance Test Per Procedure +, 05000389/LER-1987-006-03, :on 870917,discovered That Test of Emergency Diesel Generator Automatic Load Sequence Relays Incomplete. Caused by Personnel Error.Personnel Immediately Performed Required Surveillance Test Per Procedure +, 05000389/LER-1987-006-03, :on 870917,discovered That Test of Emergency Diesel Generator Automatic Load Sequence Relays Incomplete. Caused by Personnel Error.Personnel Immediately Performed Required Surveillance Test Per Procedure +, 05000389/LER-1987-006-03, :on 870917,discovered That Test of Emergency Diesel Generator Automatic Load Sequence Relays Incomplete. Caused by Personnel Error.Personnel Immediately Performed Required Surveillance Test Per Procedure +, 05000389/LER-1987-006-03, :on 870917,discovered That Test of Emergency Diesel Generator Automatic Load Sequence Relays Incomplete. Caused by Personnel Error.Personnel Immediately Performed Required Surveillance Test Per Procedure +, 05000389/LER-1987-006-03, :on 870917,discovered That Test of Emergency Diesel Generator Automatic Load Sequence Relays Incomplete. Caused by Personnel Error.Personnel Immediately Performed Required Surveillance Test Per Procedure +, 05000389/LER-1987-006-03, :on 870917,discovered That Test of Emergency Diesel Generator Automatic Load Sequence Relays Incomplete. Caused by Personnel Error.Personnel Immediately Performed Required Surveillance Test Per Procedure +, 05000389/LER-1987-006-03, :on 870917,discovered That Test of Emergency Diesel Generator Automatic Load Sequence Relays Incomplete. Caused by Personnel Error.Personnel Immediately Performed Required Surveillance Test Per Procedure +  and 05000389/LER-1987-006-03, :on 870917,discovered That Test of Emergency Diesel Generator Automatic Load Sequence Relays Incomplete. Caused by Personnel Error.Personnel Immediately Performed Required Surveillance Test Per Procedure +
2.546296e-4 d (0.00611 hours, 3.637566e-5 weeks, 8.371e-6 months)  +
October 16, 1987  +
1,987  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
19:47:07, 8 January 2025  +
October 16, 1987  +
:on 870917,discovered That Test of Emergency Diesel Generator Automatic Load Sequence Relays Incomplete. Caused by Personnel Error.Personnel Immediately Performed Required Surveillance Test Per Procedure   +