Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000366/LER-1988-007, :on 880212,valves Did Not Pass Local Leak Rate Testing & Air Supply Lines Did Not Meet All Sys Design Requirements in Fsar.Caused by Design Deficiency.Valve Deficiencies Corrected & Valve Design Changed +, 05000366/LER-1988-007, :on 880212,valves Did Not Pass Local Leak Rate Testing & Air Supply Lines Did Not Meet All Sys Design Requirements in Fsar.Caused by Design Deficiency.Valve Deficiencies Corrected & Valve Design Changed +, 05000366/LER-1988-007, :on 880212,valves Did Not Pass Local Leak Rate Testing & Air Supply Lines Did Not Meet All Sys Design Requirements in Fsar.Caused by Design Deficiency.Valve Deficiencies Corrected & Valve Design Changed +, 05000366/LER-1988-007, :on 880212,valves Did Not Pass Local Leak Rate Testing & Air Supply Lines Did Not Meet All Sys Design Requirements in Fsar.Caused by Design Deficiency.Valve Deficiencies Corrected & Valve Design Changed +, 05000366/LER-1988-007, :on 880212,valves Did Not Pass Local Leak Rate Testing & Air Supply Lines Did Not Meet All Sys Design Requirements in Fsar.Caused by Design Deficiency.Valve Deficiencies Corrected & Valve Design Changed +, 05000366/LER-1988-007, :on 880212,valves Did Not Pass Local Leak Rate Testing & Air Supply Lines Did Not Meet All Sys Design Requirements in Fsar.Caused by Design Deficiency.Valve Deficiencies Corrected & Valve Design Changed +, 05000366/LER-1988-007, :on 880212,valves Did Not Pass Local Leak Rate Testing & Air Supply Lines Did Not Meet All Sys Design Requirements in Fsar.Caused by Design Deficiency.Valve Deficiencies Corrected & Valve Design Changed +, 05000366/LER-1988-007, :on 880212,valves Did Not Pass Local Leak Rate Testing & Air Supply Lines Did Not Meet All Sys Design Requirements in Fsar.Caused by Design Deficiency.Valve Deficiencies Corrected & Valve Design Changed +, 05000366/LER-1988-007, :on 880212,valves Did Not Pass Local Leak Rate Testing & Air Supply Lines Did Not Meet All Sys Design Requirements in Fsar.Caused by Design Deficiency.Valve Deficiencies Corrected & Valve Design Changed +, 05000366/LER-1988-007, :on 880212,valves Did Not Pass Local Leak Rate Testing & Air Supply Lines Did Not Meet All Sys Design Requirements in Fsar.Caused by Design Deficiency.Valve Deficiencies Corrected & Valve Design Changed +, 05000366/LER-1988-007, :on 880212,valves Did Not Pass Local Leak Rate Testing & Air Supply Lines Did Not Meet All Sys Design Requirements in Fsar.Caused by Design Deficiency.Valve Deficiencies Corrected & Valve Design Changed +, 05000366/LER-1988-007, :on 880212,valves Did Not Pass Local Leak Rate Testing & Air Supply Lines Did Not Meet All Sys Design Requirements in Fsar.Caused by Design Deficiency.Valve Deficiencies Corrected & Valve Design Changed +, 05000366/LER-1988-007, :on 880212,valves Did Not Pass Local Leak Rate Testing & Air Supply Lines Did Not Meet All Sys Design Requirements in Fsar.Caused by Design Deficiency.Valve Deficiencies Corrected & Valve Design Changed + and 05000366/LER-1988-007, :on 880212,valves Did Not Pass Local Leak Rate Testing & Air Supply Lines Did Not Meet All Sys Design Requirements in Fsar.Caused by Design Deficiency.Valve Deficiencies Corrected & Valve Design Changed +
May 15, 1989 +
7 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
20:59:05, 26 June 2025 +
20 +
Processing error"Processing error" is a predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> and represents errors that appeared in connection with improper value annotations or input processing.
42SV-TET-001-2 +, 2T48-F323A +, 2T48-F342A +, 1T48-F342K +, 2T48-F342A-L +, 3ino-oio +, 42SV-TET-001-25 +, X7GJ17-H310 +, 2T48-F342 +, 73K-001 +, 75F-009 + and 1T48-F342 +
May 15, 1989 +
:on 880212,valves Did Not Pass Local Leak Rate Testing & Air Supply Lines Did Not Meet All Sys Design Requirements in Fsar.Caused by Design Deficiency.Valve Deficiencies Corrected & Valve Design Changed
+
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.