Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000333/LER-1995-011-01, :on 950531,leakage of Primary Containment Isolation Valves Was Exceeded.Caused by 02-2AOV-39 & 02- 2AOV-40 Experiencing Repeated Difficulty in Passing Llrt. Flushed Seat on Inboard Isolation Valve +, 05000333/LER-1995-011-01, :on 950531,leakage of Primary Containment Isolation Valves Was Exceeded.Caused by 02-2AOV-39 & 02- 2AOV-40 Experiencing Repeated Difficulty in Passing Llrt. Flushed Seat on Inboard Isolation Valve +, 05000333/LER-1995-011-01, :on 950531,leakage of Primary Containment Isolation Valves Was Exceeded.Caused by 02-2AOV-39 & 02- 2AOV-40 Experiencing Repeated Difficulty in Passing Llrt. Flushed Seat on Inboard Isolation Valve +, 05000333/LER-1995-011-01, :on 950531,leakage of Primary Containment Isolation Valves Was Exceeded.Caused by 02-2AOV-39 & 02- 2AOV-40 Experiencing Repeated Difficulty in Passing Llrt. Flushed Seat on Inboard Isolation Valve +, 05000333/LER-1995-011-01, :on 950531,leakage of Primary Containment Isolation Valves Was Exceeded.Caused by 02-2AOV-39 & 02- 2AOV-40 Experiencing Repeated Difficulty in Passing Llrt. Flushed Seat on Inboard Isolation Valve +, 05000333/LER-1995-011-01, :on 950531,leakage of Primary Containment Isolation Valves Was Exceeded.Caused by 02-2AOV-39 & 02- 2AOV-40 Experiencing Repeated Difficulty in Passing Llrt. Flushed Seat on Inboard Isolation Valve +, 05000333/LER-1995-011-01, :on 950531,leakage of Primary Containment Isolation Valves Was Exceeded.Caused by 02-2AOV-39 & 02- 2AOV-40 Experiencing Repeated Difficulty in Passing Llrt. Flushed Seat on Inboard Isolation Valve +, 05000333/LER-1995-011-01, :on 950531,leakage of Primary Containment Isolation Valves Was Exceeded.Caused by 02-2AOV-39 & 02- 2AOV-40 Experiencing Repeated Difficulty in Passing Llrt. Flushed Seat on Inboard Isolation Valve +, 05000333/LER-1995-011-01, :on 950531,leakage of Primary Containment Isolation Valves Was Exceeded.Caused by 02-2AOV-39 & 02- 2AOV-40 Experiencing Repeated Difficulty in Passing Llrt. Flushed Seat on Inboard Isolation Valve +, 05000333/LER-1995-011-01, :on 950531,leakage of Primary Containment Isolation Valves Was Exceeded.Caused by 02-2AOV-39 & 02- 2AOV-40 Experiencing Repeated Difficulty in Passing Llrt. Flushed Seat on Inboard Isolation Valve +, 05000333/LER-1995-011-01, :on 950531,leakage of Primary Containment Isolation Valves Was Exceeded.Caused by 02-2AOV-39 & 02- 2AOV-40 Experiencing Repeated Difficulty in Passing Llrt. Flushed Seat on Inboard Isolation Valve +, 05000333/LER-1995-011-01, :on 950531,leakage of Primary Containment Isolation Valves Was Exceeded.Caused by 02-2AOV-39 & 02- 2AOV-40 Experiencing Repeated Difficulty in Passing Llrt. Flushed Seat on Inboard Isolation Valve +, 05000333/LER-1995-011-01, :on 950531,leakage of Primary Containment Isolation Valves Was Exceeded.Caused by 02-2AOV-39 & 02- 2AOV-40 Experiencing Repeated Difficulty in Passing Llrt. Flushed Seat on Inboard Isolation Valve +, 05000333/LER-1995-011-01, :on 950531,leakage of Primary Containment Isolation Valves Was Exceeded.Caused by 02-2AOV-39 & 02- 2AOV-40 Experiencing Repeated Difficulty in Passing Llrt. Flushed Seat on Inboard Isolation Valve +, 05000333/LER-1995-011-01, :on 950531,leakage of Primary Containment Isolation Valves Was Exceeded.Caused by 02-2AOV-39 & 02- 2AOV-40 Experiencing Repeated Difficulty in Passing Llrt. Flushed Seat on Inboard Isolation Valve +, 05000333/LER-1995-011-01, :on 950531,leakage of Primary Containment Isolation Valves Was Exceeded.Caused by 02-2AOV-39 & 02- 2AOV-40 Experiencing Repeated Difficulty in Passing Llrt. Flushed Seat on Inboard Isolation Valve +, 05000333/LER-1995-011-01, :on 950531,leakage of Primary Containment Isolation Valves Was Exceeded.Caused by 02-2AOV-39 & 02- 2AOV-40 Experiencing Repeated Difficulty in Passing Llrt. Flushed Seat on Inboard Isolation Valve +, 05000333/LER-1995-011-01, :on 950531,leakage of Primary Containment Isolation Valves Was Exceeded.Caused by 02-2AOV-39 & 02- 2AOV-40 Experiencing Repeated Difficulty in Passing Llrt. Flushed Seat on Inboard Isolation Valve +, 05000333/LER-1995-011-01, :on 950531,leakage of Primary Containment Isolation Valves Was Exceeded.Caused by 02-2AOV-39 & 02- 2AOV-40 Experiencing Repeated Difficulty in Passing Llrt. Flushed Seat on Inboard Isolation Valve +, 05000333/LER-1995-011-01, :on 950531,leakage of Primary Containment Isolation Valves Was Exceeded.Caused by 02-2AOV-39 & 02- 2AOV-40 Experiencing Repeated Difficulty in Passing Llrt. Flushed Seat on Inboard Isolation Valve + and 05000333/LER-1995-011-01, :on 950531,leakage of Primary Containment Isolation Valves Was Exceeded.Caused by 02-2AOV-39 & 02- 2AOV-40 Experiencing Repeated Difficulty in Passing Llrt. Flushed Seat on Inboard Isolation Valve +
June 26, 1995 +
11 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
07:27:05, 26 May 2025 +
4 +
Processing error"Processing error" is a predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> and represents errors that appeared in connection with improper value annotations or input processing.
Request +
10 CFR 50.73(a)(2)(iv), System Actuation +, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications +, 10 CFR 50.73(a)(2)(i) +, 10 CFR 50.73(a)(2)(x) +, 10 CFR 50.73(a)(2)(iii) +, 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition +, 10 CFR 50.73(a)(2)(viii)(A) + and 10 CFR 50.73(a)(2)(viii)(B) +
June 26, 1995 +
:on 950531,leakage of Primary Containment Isolation Valves Was Exceeded.Caused by 02-2AOV-39 & 02- 2AOV-40 Experiencing Repeated Difficulty in Passing Llrt. Flushed Seat on Inboard Isolation Valve
+
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.