Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000331/LER-1982-067-03, /03L-0:on 821012,LPCI Injection Valve A,MOV-2003 Failed to Close.Caused by Excessive Torque from Binding Operator Due to Loose Yoke Ring Resulting from Inadequate Maint & Personnel Training.Bolt Torqued +, 05000331/LER-1982-067-03, /03L-0:on 821012,LPCI Injection Valve A,MOV-2003 Failed to Close.Caused by Excessive Torque from Binding Operator Due to Loose Yoke Ring Resulting from Inadequate Maint & Personnel Training.Bolt Torqued +, 05000331/LER-1982-067-03, /03L-0:on 821012,LPCI Injection Valve A,MOV-2003 Failed to Close.Caused by Excessive Torque from Binding Operator Due to Loose Yoke Ring Resulting from Inadequate Maint & Personnel Training.Bolt Torqued +, 05000331/LER-1982-067-03, /03L-0:on 821012,LPCI Injection Valve A,MOV-2003 Failed to Close.Caused by Excessive Torque from Binding Operator Due to Loose Yoke Ring Resulting from Inadequate Maint & Personnel Training.Bolt Torqued +, 05000331/LER-1982-067-03, /03L-0:on 821012,LPCI Injection Valve A,MOV-2003 Failed to Close.Caused by Excessive Torque from Binding Operator Due to Loose Yoke Ring Resulting from Inadequate Maint & Personnel Training.Bolt Torqued +, 05000331/LER-1982-067-03, /03L-0:on 821012,LPCI Injection Valve A,MOV-2003 Failed to Close.Caused by Excessive Torque from Binding Operator Due to Loose Yoke Ring Resulting from Inadequate Maint & Personnel Training.Bolt Torqued +, 05000331/LER-1982-067-03, /03L-0:on 821012,LPCI Injection Valve A,MOV-2003 Failed to Close.Caused by Excessive Torque from Binding Operator Due to Loose Yoke Ring Resulting from Inadequate Maint & Personnel Training.Bolt Torqued +, 05000331/LER-1982-067-03, /03L-0:on 821012,LPCI Injection Valve A,MOV-2003 Failed to Close.Caused by Excessive Torque from Binding Operator Due to Loose Yoke Ring Resulting from Inadequate Maint & Personnel Training.Bolt Torqued +, 05000331/LER-1982-067-03, /03L-0:on 821012,LPCI Injection Valve A,MOV-2003 Failed to Close.Caused by Excessive Torque from Binding Operator Due to Loose Yoke Ring Resulting from Inadequate Maint & Personnel Training.Bolt Torqued +, 05000331/LER-1982-067-03, /03L-0:on 821012,LPCI Injection Valve A,MOV-2003 Failed to Close.Caused by Excessive Torque from Binding Operator Due to Loose Yoke Ring Resulting from Inadequate Maint & Personnel Training.Bolt Torqued +, 05000331/LER-1982-067-03, /03L-0:on 821012,LPCI Injection Valve A,MOV-2003 Failed to Close.Caused by Excessive Torque from Binding Operator Due to Loose Yoke Ring Resulting from Inadequate Maint & Personnel Training.Bolt Torqued +, 05000331/LER-1982-067-03, /03L-0:on 821012,LPCI Injection Valve A,MOV-2003 Failed to Close.Caused by Excessive Torque from Binding Operator Due to Loose Yoke Ring Resulting from Inadequate Maint & Personnel Training.Bolt Torqued +, 05000331/LER-1982-067-03, /03L-0:on 821012,LPCI Injection Valve A,MOV-2003 Failed to Close.Caused by Excessive Torque from Binding Operator Due to Loose Yoke Ring Resulting from Inadequate Maint & Personnel Training.Bolt Torqued +  and 05000331/LER-1982-067-03, /03L-0:on 821012,LPCI Injection Valve A,MOV-2003 Failed to Close.Caused by Excessive Torque from Binding Operator Due to Loose Yoke Ring Resulting from Inadequate Maint & Personnel Training.Bolt Torqued +
2.314815e-5 d (5.555556e-4 hours, 3.306878e-6 weeks, 7.61e-7 months)  +
November 5, 1982  +
1,982  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
23:21:20, 16 December 2024  +
November 5, 1982  +
/03L-0:on 821012,LPCI Injection Valve A,MOV-2003 Failed to Close.Caused by Excessive Torque from Binding Operator Due to Loose Yoke Ring Resulting from Inadequate Maint & Personnel Training.Bolt Torqued  +