Browse wiki
Jump to navigation
Jump to search
ML20070L671 +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000328/LER-1982-134-03, /03L-0:on 821124,while in Mode 5,refueling Water Storage Tank Level Channel LT-63-52 Declared Inoperable Due to Failure to Meet Surveillance Requirements.Caused by Transmitter Drift.Loop Recalibr & Returned to Svc +, 05000328/LER-1982-134-03, /03L-0:on 821124,while in Mode 5,refueling Water Storage Tank Level Channel LT-63-52 Declared Inoperable Due to Failure to Meet Surveillance Requirements.Caused by Transmitter Drift.Loop Recalibr & Returned to Svc +, 05000328/LER-1982-134-03, /03L-0:on 821124,while in Mode 5,refueling Water Storage Tank Level Channel LT-63-52 Declared Inoperable Due to Failure to Meet Surveillance Requirements.Caused by Transmitter Drift.Loop Recalibr & Returned to Svc +, 05000328/LER-1982-134-03, /03L-0:on 821124,while in Mode 5,refueling Water Storage Tank Level Channel LT-63-52 Declared Inoperable Due to Failure to Meet Surveillance Requirements.Caused by Transmitter Drift.Loop Recalibr & Returned to Svc +, 05000328/LER-1982-134-03, /03L-0:on 821124,while in Mode 5,refueling Water Storage Tank Level Channel LT-63-52 Declared Inoperable Due to Failure to Meet Surveillance Requirements.Caused by Transmitter Drift.Loop Recalibr & Returned to Svc +, 05000328/LER-1982-134-03, /03L-0:on 821124,while in Mode 5,refueling Water Storage Tank Level Channel LT-63-52 Declared Inoperable Due to Failure to Meet Surveillance Requirements.Caused by Transmitter Drift.Loop Recalibr & Returned to Svc +, 05000328/LER-1982-134-03, /03L-0:on 821124,while in Mode 5,refueling Water Storage Tank Level Channel LT-63-52 Declared Inoperable Due to Failure to Meet Surveillance Requirements.Caused by Transmitter Drift.Loop Recalibr & Returned to Svc +, 05000328/LER-1982-134-03, /03L-0:on 821124,while in Mode 5,refueling Water Storage Tank Level Channel LT-63-52 Declared Inoperable Due to Failure to Meet Surveillance Requirements.Caused by Transmitter Drift.Loop Recalibr & Returned to Svc +, 05000328/LER-1982-134-03, /03L-0:on 821124,while in Mode 5,refueling Water Storage Tank Level Channel LT-63-52 Declared Inoperable Due to Failure to Meet Surveillance Requirements.Caused by Transmitter Drift.Loop Recalibr & Returned to Svc +, 05000328/LER-1982-134-03, /03L-0:on 821124,while in Mode 5,refueling Water Storage Tank Level Channel LT-63-52 Declared Inoperable Due to Failure to Meet Surveillance Requirements.Caused by Transmitter Drift.Loop Recalibr & Returned to Svc +, 05000328/LER-1982-134-03, /03L-0:on 821124,while in Mode 5,refueling Water Storage Tank Level Channel LT-63-52 Declared Inoperable Due to Failure to Meet Surveillance Requirements.Caused by Transmitter Drift.Loop Recalibr & Returned to Svc +, 05000328/LER-1982-134-03, /03L-0:on 821124,while in Mode 5,refueling Water Storage Tank Level Channel LT-63-52 Declared Inoperable Due to Failure to Meet Surveillance Requirements.Caused by Transmitter Drift.Loop Recalibr & Returned to Svc +, 05000328/LER-1982-134-03, /03L-0:on 821124,while in Mode 5,refueling Water Storage Tank Level Channel LT-63-52 Declared Inoperable Due to Failure to Meet Surveillance Requirements.Caused by Transmitter Drift.Loop Recalibr & Returned to Svc + and 05000328/LER-1982-134-03, /03L-0:on 821124,while in Mode 5,refueling Water Storage Tank Level Channel LT-63-52 Declared Inoperable Due to Failure to Meet Surveillance Requirements.Caused by Transmitter Drift.Loop Recalibr & Returned to Svc +
December 22, 1982 +
134 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
14:26:30, 16 December 2024 +
1 +
Other +
December 22, 1982 +
/03L-0:on 821124,while in Mode 5,refueling Water Storage Tank Level Channel LT-63-52 Declared Inoperable Due to Failure to Meet Surveillance Requirements.Caused by Transmitter Drift.Loop Recalibr & Returned to Svc +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.