Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000313/LER-1989-022, :on 890120,RCS Backleakage Occurred Through failed-open Check Valve Resulted in Design Temp of Hpis Piping Being Exceeded.Caused by Failure of Support Designer to Use Correct Load.New Support Replaced +, 05000313/LER-1989-022, :on 890120,RCS Backleakage Occurred Through failed-open Check Valve Resulted in Design Temp of Hpis Piping Being Exceeded.Caused by Failure of Support Designer to Use Correct Load.New Support Replaced +, 05000313/LER-1989-022, :on 890120,RCS Backleakage Occurred Through failed-open Check Valve Resulted in Design Temp of Hpis Piping Being Exceeded.Caused by Failure of Support Designer to Use Correct Load.New Support Replaced +, 05000313/LER-1989-022, :on 890120,RCS Backleakage Occurred Through failed-open Check Valve Resulted in Design Temp of Hpis Piping Being Exceeded.Caused by Failure of Support Designer to Use Correct Load.New Support Replaced +, 05000313/LER-1989-022, :on 890120,RCS Backleakage Occurred Through failed-open Check Valve Resulted in Design Temp of Hpis Piping Being Exceeded.Caused by Failure of Support Designer to Use Correct Load.New Support Replaced +, 05000313/LER-1989-022, :on 890120,RCS Backleakage Occurred Through failed-open Check Valve Resulted in Design Temp of Hpis Piping Being Exceeded.Caused by Failure of Support Designer to Use Correct Load.New Support Replaced +, 05000313/LER-1989-022, :on 890120,RCS Backleakage Occurred Through failed-open Check Valve Resulted in Design Temp of Hpis Piping Being Exceeded.Caused by Failure of Support Designer to Use Correct Load.New Support Replaced +, 05000313/LER-1989-022, :on 890120,RCS Backleakage Occurred Through failed-open Check Valve Resulted in Design Temp of Hpis Piping Being Exceeded.Caused by Failure of Support Designer to Use Correct Load.New Support Replaced +, 05000313/LER-1989-022, :on 890120,RCS Backleakage Occurred Through failed-open Check Valve Resulted in Design Temp of Hpis Piping Being Exceeded.Caused by Failure of Support Designer to Use Correct Load.New Support Replaced +, 05000313/LER-1989-022, :on 890120,RCS Backleakage Occurred Through failed-open Check Valve Resulted in Design Temp of Hpis Piping Being Exceeded.Caused by Failure of Support Designer to Use Correct Load.New Support Replaced +, 05000313/LER-1989-022, :on 890120,RCS Backleakage Occurred Through failed-open Check Valve Resulted in Design Temp of Hpis Piping Being Exceeded.Caused by Failure of Support Designer to Use Correct Load.New Support Replaced +, 05000313/LER-1989-022, :on 890120,RCS Backleakage Occurred Through failed-open Check Valve Resulted in Design Temp of Hpis Piping Being Exceeded.Caused by Failure of Support Designer to Use Correct Load.New Support Replaced +, 05000313/LER-1989-022, :on 890120,RCS Backleakage Occurred Through failed-open Check Valve Resulted in Design Temp of Hpis Piping Being Exceeded.Caused by Failure of Support Designer to Use Correct Load.New Support Replaced +, 05000313/LER-1989-022, :on 890120,RCS Backleakage Occurred Through failed-open Check Valve Resulted in Design Temp of Hpis Piping Being Exceeded.Caused by Failure of Support Designer to Use Correct Load.New Support Replaced +, 05000313/LER-1989-022, :on 890120,RCS Backleakage Occurred Through failed-open Check Valve Resulted in Design Temp of Hpis Piping Being Exceeded.Caused by Failure of Support Designer to Use Correct Load.New Support Replaced +, 05000313/LER-1989-022, :on 890120,RCS Backleakage Occurred Through failed-open Check Valve Resulted in Design Temp of Hpis Piping Being Exceeded.Caused by Failure of Support Designer to Use Correct Load.New Support Replaced +, 05000313/LER-1989-022, :on 890120,RCS Backleakage Occurred Through failed-open Check Valve Resulted in Design Temp of Hpis Piping Being Exceeded.Caused by Failure of Support Designer to Use Correct Load.New Support Replaced +, 05000313/LER-1989-022, :on 890120,RCS Backleakage Occurred Through failed-open Check Valve Resulted in Design Temp of Hpis Piping Being Exceeded.Caused by Failure of Support Designer to Use Correct Load.New Support Replaced +, 05000313/LER-1989-022, :on 890120,RCS Backleakage Occurred Through failed-open Check Valve Resulted in Design Temp of Hpis Piping Being Exceeded.Caused by Failure of Support Designer to Use Correct Load.New Support Replaced +, 05000313/LER-1989-022, :on 890120,RCS Backleakage Occurred Through failed-open Check Valve Resulted in Design Temp of Hpis Piping Being Exceeded.Caused by Failure of Support Designer to Use Correct Load.New Support Replaced +, 05000313/LER-1989-022, :on 890120,RCS Backleakage Occurred Through failed-open Check Valve Resulted in Design Temp of Hpis Piping Being Exceeded.Caused by Failure of Support Designer to Use Correct Load.New Support Replaced + and 05000313/LER-1989-022, :on 890120,RCS Backleakage Occurred Through failed-open Check Valve Resulted in Design Temp of Hpis Piping Being Exceeded.Caused by Failure of Support Designer to Use Correct Load.New Support Replaced +
June 16, 1989 +
22 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:54:31, 27 June 2025 +
4 +
10 CFR 50.73(a)(2)(v), Loss of Safety Function +, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability +, 10 CFR 50.73(a)(2)(iv), System Actuation +, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications +, 10 CFR 50.73(a)(2)(x) +, 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition +, 10 CFR 50.73(a)(2) +, 10 CFR 50.73(a)(2)(viii)(B) + and 10 CFR 50.73(a)(2)(1) +
June 16, 1989 +
Washington + and Arkansas +
:on 890120,RCS Backleakage Occurred Through failed-open Check Valve Resulted in Design Temp of Hpis Piping Being Exceeded.Caused by Failure of Support Designer to Use Correct Load.New Support Replaced
+