Browse wiki
Jump to navigation
Jump to search
ML20081M035 +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000298/LER-1995-007, :on 950224,iodine Channel of CR Air Sampling Monitor RMV-RM-1 Failed to Meet Calibr Tolerance Required by Sp 6.4.6.3.1 Due to Inadequate Procedure.Sps 6.4.6.3.1 & 6.2.3.3.1 Will Be Revised by 950430 +, 05000298/LER-1995-007, :on 950224,iodine Channel of CR Air Sampling Monitor RMV-RM-1 Failed to Meet Calibr Tolerance Required by Sp 6.4.6.3.1 Due to Inadequate Procedure.Sps 6.4.6.3.1 & 6.2.3.3.1 Will Be Revised by 950430 +, 05000298/LER-1995-007, :on 950224,iodine Channel of CR Air Sampling Monitor RMV-RM-1 Failed to Meet Calibr Tolerance Required by Sp 6.4.6.3.1 Due to Inadequate Procedure.Sps 6.4.6.3.1 & 6.2.3.3.1 Will Be Revised by 950430 +, 05000298/LER-1995-007, :on 950224,iodine Channel of CR Air Sampling Monitor RMV-RM-1 Failed to Meet Calibr Tolerance Required by Sp 6.4.6.3.1 Due to Inadequate Procedure.Sps 6.4.6.3.1 & 6.2.3.3.1 Will Be Revised by 950430 +, 05000298/LER-1995-007, :on 950224,iodine Channel of CR Air Sampling Monitor RMV-RM-1 Failed to Meet Calibr Tolerance Required by Sp 6.4.6.3.1 Due to Inadequate Procedure.Sps 6.4.6.3.1 & 6.2.3.3.1 Will Be Revised by 950430 +, 05000298/LER-1995-007, :on 950224,iodine Channel of CR Air Sampling Monitor RMV-RM-1 Failed to Meet Calibr Tolerance Required by Sp 6.4.6.3.1 Due to Inadequate Procedure.Sps 6.4.6.3.1 & 6.2.3.3.1 Will Be Revised by 950430 +, 05000298/LER-1995-007, :on 950224,iodine Channel of CR Air Sampling Monitor RMV-RM-1 Failed to Meet Calibr Tolerance Required by Sp 6.4.6.3.1 Due to Inadequate Procedure.Sps 6.4.6.3.1 & 6.2.3.3.1 Will Be Revised by 950430 +, 05000298/LER-1995-007, :on 950224,iodine Channel of CR Air Sampling Monitor RMV-RM-1 Failed to Meet Calibr Tolerance Required by Sp 6.4.6.3.1 Due to Inadequate Procedure.Sps 6.4.6.3.1 & 6.2.3.3.1 Will Be Revised by 950430 +, 05000298/LER-1995-007, :on 950224,iodine Channel of CR Air Sampling Monitor RMV-RM-1 Failed to Meet Calibr Tolerance Required by Sp 6.4.6.3.1 Due to Inadequate Procedure.Sps 6.4.6.3.1 & 6.2.3.3.1 Will Be Revised by 950430 +, 05000298/LER-1995-007, :on 950224,iodine Channel of CR Air Sampling Monitor RMV-RM-1 Failed to Meet Calibr Tolerance Required by Sp 6.4.6.3.1 Due to Inadequate Procedure.Sps 6.4.6.3.1 & 6.2.3.3.1 Will Be Revised by 950430 +, 05000298/LER-1995-007, :on 950224,iodine Channel of CR Air Sampling Monitor RMV-RM-1 Failed to Meet Calibr Tolerance Required by Sp 6.4.6.3.1 Due to Inadequate Procedure.Sps 6.4.6.3.1 & 6.2.3.3.1 Will Be Revised by 950430 +, 05000298/LER-1995-007, :on 950224,iodine Channel of CR Air Sampling Monitor RMV-RM-1 Failed to Meet Calibr Tolerance Required by Sp 6.4.6.3.1 Due to Inadequate Procedure.Sps 6.4.6.3.1 & 6.2.3.3.1 Will Be Revised by 950430 +, 05000298/LER-1995-007, :on 950224,iodine Channel of CR Air Sampling Monitor RMV-RM-1 Failed to Meet Calibr Tolerance Required by Sp 6.4.6.3.1 Due to Inadequate Procedure.Sps 6.4.6.3.1 & 6.2.3.3.1 Will Be Revised by 950430 +, 05000298/LER-1995-007, :on 950224,iodine Channel of CR Air Sampling Monitor RMV-RM-1 Failed to Meet Calibr Tolerance Required by Sp 6.4.6.3.1 Due to Inadequate Procedure.Sps 6.4.6.3.1 & 6.2.3.3.1 Will Be Revised by 950430 +, 05000298/LER-1995-007, :on 950224,iodine Channel of CR Air Sampling Monitor RMV-RM-1 Failed to Meet Calibr Tolerance Required by Sp 6.4.6.3.1 Due to Inadequate Procedure.Sps 6.4.6.3.1 & 6.2.3.3.1 Will Be Revised by 950430 +, 05000298/LER-1995-007, :on 950224,iodine Channel of CR Air Sampling Monitor RMV-RM-1 Failed to Meet Calibr Tolerance Required by Sp 6.4.6.3.1 Due to Inadequate Procedure.Sps 6.4.6.3.1 & 6.2.3.3.1 Will Be Revised by 950430 +, 05000298/LER-1995-007, :on 950224,iodine Channel of CR Air Sampling Monitor RMV-RM-1 Failed to Meet Calibr Tolerance Required by Sp 6.4.6.3.1 Due to Inadequate Procedure.Sps 6.4.6.3.1 & 6.2.3.3.1 Will Be Revised by 950430 +, 05000298/LER-1995-007, :on 950224,iodine Channel of CR Air Sampling Monitor RMV-RM-1 Failed to Meet Calibr Tolerance Required by Sp 6.4.6.3.1 Due to Inadequate Procedure.Sps 6.4.6.3.1 & 6.2.3.3.1 Will Be Revised by 950430 +, 05000298/LER-1995-007, :on 950224,iodine Channel of CR Air Sampling Monitor RMV-RM-1 Failed to Meet Calibr Tolerance Required by Sp 6.4.6.3.1 Due to Inadequate Procedure.Sps 6.4.6.3.1 & 6.2.3.3.1 Will Be Revised by 950430 +, 05000298/LER-1995-007, :on 950224,iodine Channel of CR Air Sampling Monitor RMV-RM-1 Failed to Meet Calibr Tolerance Required by Sp 6.4.6.3.1 Due to Inadequate Procedure.Sps 6.4.6.3.1 & 6.2.3.3.1 Will Be Revised by 950430 +, 05000298/LER-1995-007, :on 950224,iodine Channel of CR Air Sampling Monitor RMV-RM-1 Failed to Meet Calibr Tolerance Required by Sp 6.4.6.3.1 Due to Inadequate Procedure.Sps 6.4.6.3.1 & 6.2.3.3.1 Will Be Revised by 950430 + and 05000298/LER-1995-007, :on 950224,iodine Channel of CR Air Sampling Monitor RMV-RM-1 Failed to Meet Calibr Tolerance Required by Sp 6.4.6.3.1 Due to Inadequate Procedure.Sps 6.4.6.3.1 & 6.2.3.3.1 Will Be Revised by 950430 +
March 27, 1995 +
7 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
12:40:27, 14 December 2024 +
7 +
10 CFR 50.73(a)(2)(v), Loss of Safety Function +, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability +, 10 CFR 50.73(a)(2)(iv), System Actuation +, 10 CFR 50.73(a)(2)(i) +, 10 CFR 50.73(a)(2)(x) +, 10 CFR 50.73(a)(2)(iii) +, 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition +, 10 CFR 50.73(a)(2)(viii)(A) + and 10 CFR 50.73(a)(2)(viii)(B) +
March 27, 1995 +
Nebraska + and Washington +
:on 950224,iodine Channel of CR Air Sampling Monitor RMV-RM-1 Failed to Meet Calibr Tolerance Required by Sp 6.4.6.3.1 Due to Inadequate Procedure.Sps 6.4.6.3.1 & 6.2.3.3.1 Will Be Revised by 950430
+
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.