ML20082A791  +
05000267  +  and 00267  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000267/LER-1983-039-03, /03L-0:on 830929,w/reactor Operating at 65% Power, Problems Experienced W/Diesel Generator 1B Set During Performance of Weekly Surveillance Test.Caused by Failed Engine Trip Circuit Due to heat-brittlement of Insulation +, 05000267/LER-1983-039-03, /03L-0:on 830929,w/reactor Operating at 65% Power, Problems Experienced W/Diesel Generator 1B Set During Performance of Weekly Surveillance Test.Caused by Failed Engine Trip Circuit Due to heat-brittlement of Insulation +, 05000267/LER-1983-039-03, /03L-0:on 830929,w/reactor Operating at 65% Power, Problems Experienced W/Diesel Generator 1B Set During Performance of Weekly Surveillance Test.Caused by Failed Engine Trip Circuit Due to heat-brittlement of Insulation +, 05000267/LER-1983-039-03, /03L-0:on 830929,w/reactor Operating at 65% Power, Problems Experienced W/Diesel Generator 1B Set During Performance of Weekly Surveillance Test.Caused by Failed Engine Trip Circuit Due to heat-brittlement of Insulation +, 05000267/LER-1983-039-03, /03L-0:on 830929,w/reactor Operating at 65% Power, Problems Experienced W/Diesel Generator 1B Set During Performance of Weekly Surveillance Test.Caused by Failed Engine Trip Circuit Due to heat-brittlement of Insulation +, 05000267/LER-1983-039-03, /03L-0:on 830929,w/reactor Operating at 65% Power, Problems Experienced W/Diesel Generator 1B Set During Performance of Weekly Surveillance Test.Caused by Failed Engine Trip Circuit Due to heat-brittlement of Insulation +, 05000267/LER-1983-039-03, /03L-0:on 830929,w/reactor Operating at 65% Power, Problems Experienced W/Diesel Generator 1B Set During Performance of Weekly Surveillance Test.Caused by Failed Engine Trip Circuit Due to heat-brittlement of Insulation +, 05000267/LER-1983-039-03, /03L-0:on 830929,w/reactor Operating at 65% Power, Problems Experienced W/Diesel Generator 1B Set During Performance of Weekly Surveillance Test.Caused by Failed Engine Trip Circuit Due to heat-brittlement of Insulation +, 05000267/LER-1983-039-03, /03L-0:on 830929,w/reactor Operating at 65% Power, Problems Experienced W/Diesel Generator 1B Set During Performance of Weekly Surveillance Test.Caused by Failed Engine Trip Circuit Due to heat-brittlement of Insulation +, 05000267/LER-1983-039-03, /03L-0:on 830929,w/reactor Operating at 65% Power, Problems Experienced W/Diesel Generator 1B Set During Performance of Weekly Surveillance Test.Caused by Failed Engine Trip Circuit Due to heat-brittlement of Insulation +, 05000267/LER-1983-039-03, /03L-0:on 830929,w/reactor Operating at 65% Power, Problems Experienced W/Diesel Generator 1B Set During Performance of Weekly Surveillance Test.Caused by Failed Engine Trip Circuit Due to heat-brittlement of Insulation +  and 05000267/LER-1983-039-03, /03L-0:on 830929,w/reactor Operating at 65% Power, Problems Experienced W/Diesel Generator 1B Set During Performance of Weekly Surveillance Test.Caused by Failed Engine Trip Circuit Due to heat-brittlement of Insulation +
0.0145 d (0.349 hours, 0.00208 weeks, 4.775275e-4 months)  +, 0.0179 d (0.429 hours, 0.00255 weeks, 5.871115e-4 months)  +  and 2.314815e-5 d (5.555556e-4 hours, 3.306878e-6 weeks, 7.61e-7 months)  +
October 28, 1983  +
1,983  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
12:31:05, 14 December 2024  +
October 28, 1983  +
/03L-0:on 830929,w/reactor Operating at 65% Power, Problems Experienced W/Diesel Generator 1B Set During Performance of Weekly Surveillance Test.Caused by Failed Engine Trip Circuit Due to heat-brittlement of Insulation  +