Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000206/LER-1990-020, :on 901020,during post-maint Test to Replace screw-type Battery Jumper Cable Lugs,Concerns Raised W/ Existing Battery Terminal Resistance Measurement Methodology.Ts Surveillance Procedure Enhanced +, 05000206/LER-1990-020, :on 901020,during post-maint Test to Replace screw-type Battery Jumper Cable Lugs,Concerns Raised W/ Existing Battery Terminal Resistance Measurement Methodology.Ts Surveillance Procedure Enhanced +, 05000206/LER-1990-020, :on 901020,during post-maint Test to Replace screw-type Battery Jumper Cable Lugs,Concerns Raised W/ Existing Battery Terminal Resistance Measurement Methodology.Ts Surveillance Procedure Enhanced +, 05000206/LER-1990-020, :on 901020,during post-maint Test to Replace screw-type Battery Jumper Cable Lugs,Concerns Raised W/ Existing Battery Terminal Resistance Measurement Methodology.Ts Surveillance Procedure Enhanced +, 05000206/LER-1990-020, :on 901020,during post-maint Test to Replace screw-type Battery Jumper Cable Lugs,Concerns Raised W/ Existing Battery Terminal Resistance Measurement Methodology.Ts Surveillance Procedure Enhanced +, 05000206/LER-1990-020, :on 901020,during post-maint Test to Replace screw-type Battery Jumper Cable Lugs,Concerns Raised W/ Existing Battery Terminal Resistance Measurement Methodology.Ts Surveillance Procedure Enhanced +, 05000206/LER-1990-020, :on 901020,during post-maint Test to Replace screw-type Battery Jumper Cable Lugs,Concerns Raised W/ Existing Battery Terminal Resistance Measurement Methodology.Ts Surveillance Procedure Enhanced +, 05000206/LER-1990-020, :on 901020,during post-maint Test to Replace screw-type Battery Jumper Cable Lugs,Concerns Raised W/ Existing Battery Terminal Resistance Measurement Methodology.Ts Surveillance Procedure Enhanced +, 05000206/LER-1990-020, :on 901020,during post-maint Test to Replace screw-type Battery Jumper Cable Lugs,Concerns Raised W/ Existing Battery Terminal Resistance Measurement Methodology.Ts Surveillance Procedure Enhanced +, 05000206/LER-1990-020, :on 901020,during post-maint Test to Replace screw-type Battery Jumper Cable Lugs,Concerns Raised W/ Existing Battery Terminal Resistance Measurement Methodology.Ts Surveillance Procedure Enhanced +, 05000206/LER-1990-020, :on 901020,during post-maint Test to Replace screw-type Battery Jumper Cable Lugs,Concerns Raised W/ Existing Battery Terminal Resistance Measurement Methodology.Ts Surveillance Procedure Enhanced +, 05000206/LER-1990-020, :on 901020,during post-maint Test to Replace screw-type Battery Jumper Cable Lugs,Concerns Raised W/ Existing Battery Terminal Resistance Measurement Methodology.Ts Surveillance Procedure Enhanced +, 05000206/LER-1990-020, :on 901020,during post-maint Test to Replace screw-type Battery Jumper Cable Lugs,Concerns Raised W/ Existing Battery Terminal Resistance Measurement Methodology.Ts Surveillance Procedure Enhanced +, 05000206/LER-1990-020, :on 901020,during post-maint Test to Replace screw-type Battery Jumper Cable Lugs,Concerns Raised W/ Existing Battery Terminal Resistance Measurement Methodology.Ts Surveillance Procedure Enhanced +, 05000206/LER-1990-020, :on 901020,during post-maint Test to Replace screw-type Battery Jumper Cable Lugs,Concerns Raised W/ Existing Battery Terminal Resistance Measurement Methodology.Ts Surveillance Procedure Enhanced +, 05000206/LER-1990-020, :on 901020,during post-maint Test to Replace screw-type Battery Jumper Cable Lugs,Concerns Raised W/ Existing Battery Terminal Resistance Measurement Methodology.Ts Surveillance Procedure Enhanced +, 05000206/LER-1990-020, :on 901020,during post-maint Test to Replace screw-type Battery Jumper Cable Lugs,Concerns Raised W/ Existing Battery Terminal Resistance Measurement Methodology.Ts Surveillance Procedure Enhanced +, 05000206/LER-1990-020, :on 901020,during post-maint Test to Replace screw-type Battery Jumper Cable Lugs,Concerns Raised W/ Existing Battery Terminal Resistance Measurement Methodology.Ts Surveillance Procedure Enhanced +, 05000206/LER-1990-020, :on 901020,during post-maint Test to Replace screw-type Battery Jumper Cable Lugs,Concerns Raised W/ Existing Battery Terminal Resistance Measurement Methodology.Ts Surveillance Procedure Enhanced +, 05000206/LER-1990-020, :on 901020,during post-maint Test to Replace screw-type Battery Jumper Cable Lugs,Concerns Raised W/ Existing Battery Terminal Resistance Measurement Methodology.Ts Surveillance Procedure Enhanced +, 05000206/LER-1990-020, :on 901020,during post-maint Test to Replace screw-type Battery Jumper Cable Lugs,Concerns Raised W/ Existing Battery Terminal Resistance Measurement Methodology.Ts Surveillance Procedure Enhanced + and 05000206/LER-1990-020, :on 901020,during post-maint Test to Replace screw-type Battery Jumper Cable Lugs,Concerns Raised W/ Existing Battery Terminal Resistance Measurement Methodology.Ts Surveillance Procedure Enhanced +
January 28, 1991 +
20 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05:48:24, 11 January 2025 +
6 +
Processing error"Processing error" is a predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> and represents errors that appeared in connection with improper value annotations or input processing.
Request +
10 CFR 50.73(a)(2)(v), Loss of Safety Function +, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability +, 10 CFR 50.73(a)(2)(i) +, 10 CFR 50.73(a)(2)(x) +, 10 CFR 50.73(a)(2)(iii) +, 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition +, 10 CFR 50.73(a)(2) +, 10 CFR 50.73(a)(2)(viii)(A) + and 10 CFR 50.73(a)(2)(viii)(B) +
January 28, 1991 +
:on 901020,during post-maint Test to Replace screw-type Battery Jumper Cable Lugs,Concerns Raised W/ Existing Battery Terminal Resistance Measurement Methodology.Ts Surveillance Procedure Enhanced
+